Data Sheet
BasicPlus
Floor Heating Room Thermostats
Application
FH-CWT FH-CWD FH-CWP
The BasicPlus room thermostats are used for
room temperature control in water based oor
heating systems.
By controlling the room temperature in accordance with the temperature desired by the user,
the room thermostats provide optimal energy
savings as well as optimal thermal comfort.
The room thermostats are available in three versions:
FH-CWT Room Thermostat (with dial)
By turning the dial to the desired set-point
temperature optimal thermal comfort in the
room is achieved. In addition to temperature the
thermostat setting scale includes a frost symbol,
allowing for minimal energy consumption, while
keeping the room from freezing.
LED’s display the function of the thermostat:
• green light: the thermostat is ON, but without
heat demand.
• red light: the thermostat is ON and there is
heat demand.
FH-CWD Room Thermostats (with display)
In addition to room temperature control, the
FH-CWD can be equipped with a oor sensor,
thus allowing for control of maximum oor
temperature and reducing risk of overheated
and damaged oors. For specic maximum oor
temperatures, please refer to recommendations
from oor suppliers.
Using the Frost Protection Mode instead of
turning the thermostat OFF may protect against
damages due to low temperatures. The room
temperature will be maintained around 5° C.
FH-CWP Room Thermostat (programmable
with display)
Two available timer programs are allowing temperature setback or complete turning o the heat
supply during selected periods.
The ON / OFF Timer Function enables to program the thermostat for one period with heating
turned OFF and one period with heating turned
ON per day. During the ON period the thermostat
will regulate in relation to the set temperature
and TIMER ON will be shown in the display. During the OFF period, the heating is o, and TIMER
OFF is shown in the display.
The Advanced Programmable Timer Function
allows to set a timer controlled program for automatic change between comfort temperature and
energy saving setback temperature, when standard room comfort temperature is not required.
The Advanced Programmable Timer Function allows for 4 dierent periods / 5+2 days per week.
Ordering
VDCUA402
Product Typ e Supply Output Code no.
BasicPlus room thermostat with dial FH-CWT 230 VAC 230 VAC 088U0601
BasicPlus room thermostat with display FH- CWD 85-250 VAC 85-250 VAC 088U0602
BasicPlus programmable room thermostat
with display
FH-CWP 85-250 VAC 85-250 VAC 088U0603
© Danfoss | FHH | 2015.09 | 1
Data Sheet BasicPlus Floor Heating Room Thermostats
Accessories
Technical specications
Product Typ e Code no.
BasicPlus oor sensor FH-CWF 088U0610
FH-CWT FH-CWD FH-CWP
Adjustment mode Dial Buttons
Yes, two programs:
1. ON/OFF, two periods
Programmable -
Green: thermostat ON, no
LED indicator
LCD display - Yes, with backlight / nightlight
Temperature range 5 - 30° C 5 - 35° C
Precision ±1.5° C ±1.0° C
Frost protection
Operating rating 0 - 40 °C, 5 - 95% RH (non-condensing)
Room sensor NTC 10K, accuracy ±1% NTC 100K, accuracy ±1%
Floor sensor - Optional (FH-CWF)
Floor sensor setting
range
Sensor fault indication All outputs turned o
O-set function /
Temp. calibration
Max. load (inductive) < 1 A
Max. load (resistive) < 3 A
Power consumption 7 W 2 W
Power supply 230 VAC ±10%, 50/60 Hz 85 - 250 VAC, 50/60 Hz
Settings back-up - Settings retained if power failure
Mounting Wall mounting
Ambient temperature -10° - 60° C
Approval CE Marking, EN 60730
heat demand.
Red: thermostat ON, heat
demand.
Yes, with dial at (5° C)
- 20 - 45° C
- Yes, ±10° C
Yes, if enabled (5° C / 7° C, ON / OFF)
All outputs turned o, display shows E1 (room sensor
failure) or E2 (oor sensor failure)
Flush mounting for European and Chinese built-in
sockets
/ day
2. Automatic shift
between comfort and
setback temp., 4 periods /
5 + 2 days
-
2 | © Danfoss | FHH | 2015.09
ErP class
IP class 30
Shell material ABS + PC, inammable
Static protection Yes
Colour
Dimensions 86 x 99 x 29 mm 86 x 99 x 19 mm 86 x 99 x 19 mm
White RAL 9016 /
Grey RAL 7011
(1%)
White RAL 9016
VDCUA402