Danfoss FFKM, FKM Installation guide

0 (0)
Danfoss FFKM, FKM Installation guide

Installation Guide

FFKM and FKM replacement O-ring kits for REG-SA/SB, DN 10 to 40 and SCA-X / CHV-X all sizes (DN 15 to 125)

<![if ! IE]>

<![endif]>148R9633

 

 

WHITE tag

REG example:

 

 

 

FFKM (R717 HP)

 

 

 

 

+

FKM (R1270)

 

 

 

 

 

 

 

BLUE tag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue tag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

<![if ! IE]>

<![endif]>148R9633

Do not remove the bonnet while the valve is still under pressure.

Remove the standard CR O-ring from the valve with a “soft” tool preventing scratching of the valve O-ring groove (fig. 1).

Lubricate the O-ring with oil (same type as the compressor oil), then mount the new FFKM or FKM O-ring + tag (fig. 2) for the correct FFKM or FKM O-ring type.

FFKM O-ring (WHITE tag):

Applicable for R717 (NH ) heat pump applications in the temperature range of +100°C and +150°C.

FKM O-ring (BLUE tag):

Applicable for R1270 (Propylene) applications in the continous temperature range of -60°C and +150°C.

© Danfoss | DCS (MWA) | 2018.11

AN286852232026en-000102 | 1