Installation Guide
FFKM and FKM replacement O-ring kits for REG-SA/SB, DN 10 to 40 and SCA-X / CHV-X all sizes (DN 15 to 125)
<![if ! IE]> <![endif]>148R9633 |
|
|
WHITE tag |
REG example: |
|||
|
|
|
FFKM (R717 HP) |
|
|
|
|
+ |
FKM (R1270) |
|
|
|
|
||
|
|
|
BLUE tag |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Blue tag |
|
|
|
|
|
|
|
||
|
|
|
|
||||
|
|
|
|
|
|
1 |
2 |
<![endif]>148R9633
•Do not remove the bonnet while the valve is still under pressure.
•Remove the standard CR O-ring from the valve with a “soft” tool preventing scratching of the valve O-ring groove (fig. 1).
•Lubricate the O-ring with oil (same type as the compressor oil), then mount the new FFKM or FKM O-ring + tag (fig. 2) for the correct FFKM or FKM O-ring type.
FFKM O-ring (WHITE tag):
Applicable for R717 (NH ) heat pump applications in the temperature range of +100°C and +150°C.
FKM O-ring (BLUE tag):
Applicable for R1270 (Propylene) applications in the continous temperature range of -60°C and +150°C.
© Danfoss | DCS (MWA) | 2018.11 |
AN286852232026en-000102 | 1 |