Danfoss FF8.5GX Data sheet

FF8.5GX Universal Compressor R134a 115V 60Hz
General
Code number 103G5880
Approvals UL984
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °F -22 to 50
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F1F1F
100°F F1F1F
110°F F1F1F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 28.0
Cut in Current, HST | LST A 28.0
Resistance, main | start winding (77°F) 1.9 6.6
Design
Displacement cu.in 0.48
Oil quantity (type) .oz. 13.5 (polyolester)
Maximum refrigerant charge oz. 32.0
Free gas volume in compressor .oz. 47.3
Weight without electrical equipment lbs. 23.3
Dimensions
Height inch A 7.72
Suction connector location, I.D. in. | angle C 0.320-0.327 | 30°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 30°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 25°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.52
B1
B2
S = Static cooling normally sufcient
O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
1
equal to ambient temperature)
1
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
1
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.D6.22 / 502N1245 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 443 588 662 957 1328 1490 1773 2294 2404 2890 3217 3563
Power cons. in W 172 198 209 245 283 299 321 359 369 398 418 437
Current cons. in A 3.13 3.22 3.27 3.45 3.67 3.77 3.92 4.19 4.25 4.46 4.59 4.72
EER in BTU/Wh 2.57 2.98 3.18 3.90 4.69 4.98 5.53 6.38 6.51 7.26 7.70 8.14
ASHRAE HBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 392 522 587 848 1176 1336 1570 2029 2141 2555 2842 3146
Power cons. in W 172 198 209 245 283 297 321 359 366 398 418 437
Current cons. in A 3.13 3.22 3.27 3.45 3.67 3.77 3.92 4.19 4.24 4.46 4.59 4.72
EER in BTU/Wh 2.28 2.64 2.81 3.46 4.16 4.50 4.89 5.65 5.83 6.41 6.80 7.19
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in W 106 141 158 229 317 354 423 547 569 688 765 846
Power cons. in W 172 198 209 245 283 299 321 359 369 398 418 437
Current cons. in A 3.13 3.22 3.27 3.45 3.67 3.77 3.92 4.19 4.25 4.46 4.59 4.72
COP in W/W 0.61 0.71 0.76 0.93 1.12 1.18 1.32 1.52 1.54 1.73 1.83 1.93
Accessories for FF8.5GX Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRP36AEN-6 Ambient temp.
a2
117U4060 Condensing temp.
Cover b 117U1021 Suction gas temp.
Start. capacitor 280 µF 1/4 in. spade connect. c 117U5041 Liquid temperature
ASHRAE
ASHRAE
LBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
HBP
EN 12900/
CECOMAF
131°F
90°F
90°F
131°F
Cord relief d 117U0349
Cord relief for capacitor dc 117U0349 Mounting accessories Code number
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.D6.22 / 502N1245 Dec 2011