Danfoss FF7.5GK Data sheet

FF7.5GK Universal Compressor R134a 115V 60Hz
General
Code number 103G5780
Approvals UL984
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °F -22 to 50
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F1F1F
100°F F1F1F
110°F F1F1F
Remarks on application:
Motor
Motor type RSIR
LRA (rated after 4 sec. UL984), HST | LST A 25.0
Cut in Current, HST | LST A 25.0
Resistance, main | start winding (77°F) 2.2 8.3
Design
Displacement cu.in 0.42
Oil quantity (type) .oz. 13.5 (polyolester)
Maximum refrigerant charge oz. 32.0
Free gas volume in compressor .oz. 47.3
Weight without electrical equipment lbs. 23.3
Dimensions
Height inch A 7.72
Suction connector location, I.D. in. | angle C 0.320-0.327 | 30°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 30°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 25°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 7.52
B1
B2
S = Static cooling normally sufcient
O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
1
equal to ambient temperature)
1
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
1
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.D4.22 / 502N1244 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 328 452 516 777 1111 1258 1518 2000 2100 2556 2863 3189
Power cons. in W 115 138 148 182 216 230 250 286 294 322 340 359
Current cons. in A 1.90 2.02 2.07 2.28 2.51 2.61 2.76 3.03 3.10 3.32 3.47 3.62
EER in BTU/Wh 2.86 3.28 3.49 4.27 5.15 5.46 6.06 7.00 7.16 7.94 8.41 8.88
ASHRAE HBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in BTU/h 291 401 458 689 984 1128 1344 1769 1872 2259 2529 2816
Power cons. in W 115 138 148 182 216 229 250 286 292 322 340 359
Current cons. in A 1.90 2.02 2.07 2.28 2.51 2.61 2.76 3.03 3.09 3.32 3.47 3.62
EER in BTU/Wh 2.54 2.91 3.09 3.79 4.56 4.91 5.37 6.19 6.41 7.02 7.43 7.84
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 45 50 59 68
Capacity in W 79 108 123 186 265 299 362 477 498 608 681 757
Power cons. in W 115 138 148 182 216 230 250 286 294 322 340 359
Current cons. in A 1.90 2.02 2.07 2.28 2.51 2.61 2.76 3.03 3.10 3.32 3.47 3.62
COP in W/W 0.69 0.78 0.83 1.02 1.23 1.30 1.45 1.67 1.69 1.89 2.00 2.11
Accessories for FF7.5GK Figure Code number Test conditions
Starting relay 1/4 in. spade connect.
Protector 3/4 in. Texas Instruments MRP38JL-6 Ambient temp.
a2
117U4085 Condensing temp.
Cover (standard) b 117U1021 Suction gas temp.
Cord relief d 117U0349 Liquid temperature
ASHRAE
ASHRAE
LBP
130°F 130°F
90°F 95°F
90°F 95°F
90°F 115°F
HBP
EN 12900/
CECOMAF
131°F
90°F
90°F
131°F
(pos.1)
Cover (alternative)
with terminal board Bolt joint for one comp. Ø: 5/ 8 in . 118-1917
b
(pos.2)
117U1024
Mounting accessories Code number
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.D4.22 / 502N1244 Dec 2011