FF10GX
Universal Compressor
R134a
115V 60Hz
General
Code number |
|
|
|
|
|
103G5980 |
|
|
||
Approvals |
|
|
|
|
|
UL984 |
|
|
||
Compressors on pallet |
|
|
|
|
|
80 |
|
|
||
Application |
|
|
|
|
|
|
|
|
|
|
Application |
|
|
|
|
|
LBP/HBP |
|
|
||
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
Evaporating temperature |
|
°F |
|
|
– |
|
|
-22 to 50 |
||
Voltage range |
|
V |
|
|
– |
|
|
103 - 127 |
||
Max. condensing temperature continuous (short) |
°F |
|
|
– |
|
|
140 (158) |
|||
Max. winding temperature continuous (short) |
°F |
|
|
– |
|
|
257 (275) |
|||
Cooling requirements |
|
|
|
|
|
|
|
|
|
|
Frequency |
|
Hz |
|
50 |
|
|
|
60 |
|
|
Application |
|
|
LBP |
|
MBP |
HBP |
|
LBP |
MBP |
HBP |
90°F |
|
|
– |
|
– |
– |
|
F1 |
F1 |
F1 |
100°F |
|
|
– |
|
– |
– |
|
F1 |
F1 |
F1 |
110°F |
|
|
– |
|
– |
– |
|
F1 |
F1 |
F1 |
Remarks on application: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
|
|
|
|
Motor type |
|
|
|
|
|
CSIR |
|
|
||
LRA (rated after 4 sec. UL984), HST | LST |
A |
|
29.9 |
|
|
|
– |
|
||
Cut in Current, HST | LST |
|
A |
|
29.9 |
|
|
|
– |
|
|
Resistance, main | start winding (77°F) |
Ω |
|
1.7 |
|
|
|
5.4 |
|
||
Design |
|
|
|
|
|
|
|
|
|
|
Displacement |
|
cu.in |
|
|
|
0.55 |
|
|
||
Oil quantity (type) |
|
fl.oz. |
|
|
13.5 (polyolester) |
|
||||
Maximum refrigerant charge |
|
oz. |
|
|
|
32.0 |
|
|
||
Free gas volume in compressor |
|
fl.oz. |
|
|
|
47.3 |
|
|
||
Weight without electrical equipment |
lbs. |
|
|
|
23.3 |
|
|
|||
Dimensions |
|
|
|
|
|
|
|
|
|
|
Height |
|
inch |
A |
|
|
7.72 |
|
|
||
|
|
|
B |
|
|
7.52 |
|
|
||
|
|
|
B1 |
|
|
|
– |
|
|
|
|
|
|
B2 |
|
|
|
– |
|
|
|
Suction connector |
location, I.D. in. | angle |
C |
0.320-0.327 | 30° |
|
||||||
|
material | comment |
|
Cu-plated steel | Al cap |
|||||||
Process connector |
location, I.D. in. | angle |
D |
0.252-0.259 | 30° |
|
||||||
|
material | comment |
|
Cu-plated steel | Al cap |
|||||||
Discharge connector |
location, I.D. in. | angle |
E |
0.252-0.259 | 25° |
|
||||||
|
material | comment |
|
Cu-plated steel | Al cap |
|||||||
Oil cooler connector |
location, I.D. in. | angle |
F |
|
|
|
– |
|
|
||
|
material | comment |
|
|
|
|
– |
|
|
||
Remarks: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S |
= Static cooling normally sufficient |
||||||||||||||||||||||||||
O |
= Oil cooling |
||||||||||||||||||||||||||
F1 |
= Fan cooling 1.5 m/s |
||||||||||||||||||||||||||
|
|
(compressor compartment temperature |
|||||||||||||||||||||||||
|
|
equal to ambient temperature) |
|||||||||||||||||||||||||
F2 |
= Fan cooling 3.0 m/s necessary |
||||||||||||||||||||||||||
SG |
= Suction gas cooling normally sufficent |
–= not applicable in this area
Dec 2011 |
Manufactured by Secop for Danfoss - DEHC.ED.400.E5.22 / 502N1243 |
1/2 |