Danfoss FCM 300 Fact sheet

Danfoss FCM 300 Fact sheet

VLT® DriveMotor FCM 300

The VLT® DriveMotor FCM 300 series is an integrated drive-motor solution which combines a VLT® frequency converter and a high standard quality motor in a single product.

IE2

motors for high efficiency combined with a highperformance, energy saving VLT®.

The frequency converter is attached

Power range

in place of the motor terminal box

0.55 – 7.5 kW, 3 x 380 – 480 V

and it is no higher than the standard

Enclosure

terminal box nor wider or longer than

the motor.

IP 55 (standard)

Incorporated to a high standard

IP 65/IP 66 (optional)

Motor type

quality motor, the VLT® DriveMotor

FCM 300 is also available in a multi-

2-pole

tude of variants, individualised to

4-pole

meet customer requirements.

Mounting versions

 

On the motor

B03 foot

The VLT® electronic motor control

B05 flange

together with the motor totally

B35 foot + flange

eliminates motor cables and thereby

B14 face

minimises EMC problems. Heat from

B34 foot + face

the drive is dissipated together with

 

the motor heat.

 

Feature

Benefit

Reliable

Maximum uptime

Robust enclosure

Withstands harsh environments

No power cable length limitation

Increased flexibility

Thermal protection

Total motor-inverter protection

Straightforward EMC compliance

No problem with electromagnetic

interferences

 

User-friendly

Saves commissioning and operating cost

Motor and drive perfectly matched

Saves commissioning time

to each other

 

No panel space required – the DriveMotor is

Saves space

placed on the machine

 

Flexible mounting – foot/flange/face/

Meets customer requirements

foot-flange/foot-face

 

Retrofit without mechanical changes

Easy service

Set-up and controlled through a remote control

 

panel or fieldbus communication and dedicated

Easy commissioning

MCT 10 set-up software

 

Facts about our products

Specifications

Control panel

A Local Control Panel is used for operating, setup and diagnostics. The LCP can be handheld or mounted in a panel front (IP 65).

Sleep Mode

In Sleep Mode the motor will stop in a no load situation. When the load returns, the frequency converter will restart the motor.

Also available:

Forced ventilation

For constant operation at low speed without torque reduction.

Motor drain holes

For applications where formation of condensate water might occur.

Sensorless Pump Control

– OEM version

Offers precise pressure (head) control without using a pressure transmitter.

Mains supply (L1, L2, L3)

 

Supply voltage

3 x 380/400/415/440/460/480V ±10%

Supply frequency

50/60 Hz

Power factor (cos φ)

Max. 0.9/1.0 at rated load

Max. imbalance of supply voltage

±2% of rated supply voltage

Switching on supply input

Once every 2 minutes

Control Characteristics (frequency converter)

 

Frequency range

0 – 132 Hz

Overload torque

160% for 60 sec.

Resolution on output frequency

0.1%

System response time

30 msec. ±10 msec.

Speed accuracy

±15 RPM (open loop, CT mode,

4-pole motor 150 – 1500 RPM)

 

Digital inputs

 

Programmable digital inputs

4

Voltage level

0 – 24 V DC (PNP positive logic)

Analogue inputs

 

Analogue inputs

2 (1 voltage, 1 current)

Voltage/current level

0 – 10 V DC / 0/4 – 20 mA (scaleable)

Pulse input

 

Programmable pulse inputs

1 (24 V DC)

Max. frequency

70 kHz (push-pull) / 8 kHz (open collector)

Analogue/digital output

 

Programmable analogue/digital outputs

1

Current/voltage range

0/4 – 20 mA / 24 V DC

Relay output

 

Programmable relay outputs

1

Max. terminal load

250 V AC, 2 A, 500 VA

Fieldbus communication

 

FC Protocol, Modbus RTU

Built-in

Profibus DP

Optional (integrated)

 

 

Externals

 

Vibration test

1.0 g (IEC 60068)

Max. relative humidity

95% (IEC 60068-2-3)

Ambient temperature

Max. 40˚C (24 hour average max. 35˚C)

Min. ambient temperature in full operation

0˚C

Min. ambient temperature at reduced

-10˚C

performance

 

Technical Data

FCM

305

307

311

315

322

330

340

355

375

Motor output

 

 

 

 

 

 

 

 

 

[HP]

0.75

1.0

1.5

2.0

3.0

4.0

5.0

7.5

10.0

[kW]

0.55

0.75

1.1

1.5

2.2

3.0

4.0

5.5

7.5

Motor torque

1.8

2.4

3.5

4.8

7.0

9.5

12.6

17.5

24.0

2-pole [Nm] 1)

4-pole [Nm] 2)

3.5

4.8

7.0

9.6

14.0

19.1

25.4

35.0

48.0

Frame size [mm]

80

80

90

90

100

100

112

132

132

Input current [A] 380 V

 

 

 

 

 

 

 

 

 

2-pole

1.5

1.8

2.3

3.4

4.5

5.0

8.0

12.0

15.0

4-pole

1.4

1.7

2.5

3.3

4.7

6.4

8.0

11.0

15.5

Input current [A] 480 V

 

 

 

 

 

 

 

 

 

2-pole

1.2

1.4

1.8

2.7

3.6

4.0

6.3

9.5

11.9

4-pole

1.1

1.3

2.0

2.6

3.7

5.1

6.3

8.7

12.3

1) at 400 V, 3000 RPM

2) at 400 V, 1500 RPM

Danfoss VLT Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80 www.danfoss.com/drives • E-mail: info@danfoss.com

DKDD.PFP.701.A2.02

VLT® is a trademark of Danfoss A/S

Produced by PE-MMSC 2014.09