Danfoss EvoFlat WSS Fact sheet

Fact sheet
TM
EvoFlat
WSS
with DHW recirculation, fully insulated
Fully insulated water heater for flats, single- and multi-family houses
FEATURES AND BENEFITS
• DHW heating based on flow principle with thermostatic temperature controller
• Innovative, energy-saving controller TCP - M in combination with high performance heat exchanger for on­demand water heating
• Minimum space required for installation
• Built-in or wall-mounted variant
• Pipes and plate heat exchanger made of stainless steel
• No retightening of internal connections required, due to newly designed click connection,
• Constant DHW temperature even at fluctuating flow temperatures or differential pressures
• Minimized risk of lime scale and bacteria formation
Application
The EvoFlatTM WSS water heater is a compact and simple to operate water heater. Developped for DHW heating in systems, which are supplied from a secondary connected district heating system, a block heating sys­tem, a centrally located boiler system (oil, gas or biomass, as well as for CHP systems. A flow temperature of min. 55 °C is required. The heating side is not supported with this system. The EvoFlat
TM
water heater is available as built-in variant with a recess box or as mount-on-wall variant with cover.
Domestic hot water (DHW)
The domestic hot water is prepared in the heat exchanger based on the flow principle and the temperature is regulated by the self-acting control­ler with integrated differential pres­sure controller - the TPC-M. Supreme ease of operation is obtained via the combined hydraulic and thermostatic regulation of the TPC-M controller. The
flow-controlled part allows primary and secondary side flow through the heat exchanger, only when hot water is tapped. The thermostatic part controls the domestic hot water temperature. The TPC - M controller with integrated differential pres­sure controller also compensates for flunctuating flow temperatures and differential pressures and thereby en­sures a constant domestic hot water temperature at all times. Immediately after immediately after completion of the tapping process the flow is blocked. For registration of the cold water consumption the EvoFlat
TM
WSS water heater is equipped with a fitting piece for mounting of a cold water meter in the DCW inlet. The EvoFlatTM WSS water heater is also prefabricated with a strainer, a sensor pocket as well as a fitting piece for mounting of a heat meter.
Domestic hot water recirculation
In order to ensure the best possible DHW comfort and to have DHW available immediately, this station includes hot water circulation. This includes i.a. a circulation pump and a safety valve.
Construction
All pipes are made of stainless steel. The connections are made by a new­ly designed click connection. Compared to conventional stations with screw connections, this new connection technology does not re­quire retightening during assembly.
Insulation
The EvoFlatTM WSS water heater is built up on an EPP insulated back plate as well as a front insulation cabinet, enabling the customer to have a fully insulated substation, thus ensuring reduced heat losses and excellent operating economy.
www.danfoss.com
545
142,4
E
D
C
B
A
87
6
5
4
CIRCUIT DIAGRAM (EXAMPLE)
DHW
DCW
Outlet
DCW
Inlet
DH
Supply
DH
Return
2 Plate heat exchanger: Danfoss XB06H -1 5 Strainer 6 Non-return valve 9 Circulation pump
Yonos Para Z 15/7
12 Safety valve
23 Sensor pocket M10x1 24 Fitting piece for heat meter WMZ: 3/4” × 110 mm 33 Plug 38 DHW controller type TPC-M 40 Summer-Bypass 59 Fitting piece for DCW meter: 3/4” × 110 mm
Design specifications:
Nominal pressure: PN 10 Max. supply temperature: 95 °C DCW static pressure: P Brazing material (HEX): Copper / Stainless steel
= 1,5 bar
min
Weight excl. cover: 8,5 kg
Insulation: EPP λ 0,039
Electrical supply: 230 V AC
Dimensions (mm):
With connections: H 590 × W 550 × D 150* * Depth incl. mounting plate
With DHW recirculation: H 889 × W 582 × D 150* * Depth incl. mounting plate
Connections sizes:
G ¾“ IT (int. thread)
DHW: CAPACITY EXAMPLES 10/50°C
DHW
capacity
[[kW]
37 65/21 23 730 13.3 43 65/22 40 850 15.3 45 65/20 22 867 16.1 49 65/21 30 950 17.5 55 65/16 27 950 19.4 38 55/21 27 950 13.6 51 65/19 28 950 18.3 34 55/24 28 950 12.5
Unit typ e
HEX
XB06H-1 26 Cu/E (Type 1)
XB06H-1 40 Cu/E (Type 2)
XB06H+ 60 Cu (Type 3)
XB06H-1 56 E (Type 3)
* energy meter not incl.
588,4
889
Temperature primary
Supply/Return
[°C]
425
554,4
112 65 65 65 65 65 65 43
3 4
1 2
1 Kaltwasser (KW) Eintritt 2 Warmwassser (WW) 3 Kaltwasser (KW) Austritt 4 Fernwärme (FW) Vorlauf 5 Fernwärme (FW) Rücklauf 6 Heizung (HE) Vorlauf 7 Heizung (HE) Rücklauf
582
Pressure loss
Primary
[*kp a]
5 6
Connections:
1. Domestic cold water (DCW) inlet
2. Domestic hot water (DHW)
3. Domestic cold water (DCW) outlet
4. Heating (HE) supply
5. Heating (HE) return
6. Recirculation
Options:
• Mounting rail for wall mounted variant
• Recess box for built-in variant incl. mounting rail
7
Flow rate Primäry*
[l/h]
Tap load
[l/min.]
© Danfoss | DCS-SGDPT | 2021 .11