Danfoss EV221BW Data sheet

Data Sheet
Solenoid valve Type EV221BW
Direct servo operated for drinking water
EV221BW 10, 14, 20 and 22 is a direct servo­operated 2/2-way solenoid valve. This valve type is designed with EPDM seal, lead free dezincication resistant Eco brass for drinking water applications.
• For water supply
• Houses and large apartments
• Kitchens and bathrooms
• Industrial buildings
• Zoning
• Laundry
• Dishwashing
• Main intel valve
• Dosing machines
• Food processing
Features
• For drinking water
• Clip on coil
• Coil enclosure: Up to IP67
• Water hammer damped
• Body material in Eco Brass (lead free <0,1%) and dizincication resistant
• New generation EPDM sealings recommended for drinking water.
AI307038742363en-000302
Features
EV221BW
EV221BW
Body material
Eco brass
Eco brass
DN [mm]
10 - 22
10 - 22
Connection
G3/8'' - G1''
G3/8” - G1”
Sealing material
EPDM
EPDM
Function
NC
NO
Kv [m3/h]
1.5 - 6.0
1.5 - 6.0
Dierential pressure range [bar]
0.1 - 10
0.1 - 10
Temperature range [°C]
0 - 90
0 - 90
Solenoid valve, Type EV221BW
1 Portfolio overview
Table 1: Portfolio overview
© Danfoss | Climate Solutions | 2021.05 AI307038742363en-000302 | 2
12345678Armature spring
Armature
Valve plate
Equalizing orice
Main orice
Pilot orice
Diaphragm
Coil
Solenoid valve, Type EV221BW
2 Functions
2.1 Functions NC
Coil voltage disconnected (closed)
When the supply voltage to the coil (8) is disconnected, the valve plate (3) is pressed down against the pilot orice (6) by the armature spring (1). The pressure across the diaphragm (7) is built up via the equalizing orice (4). The diaphragm closes the main orice (5) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will be closed for as long as the voltage to the coil is disconnected.
Coil voltage connected (open)
When voltage is applied to the coil, the pilot orice (6) is opened. As the pilot orice is larger than the equalizing orice (4), the pressure across the diaphragm (7) drops and therefore it is lifted clear of the main orice (5). The valve
is now open and will be open for as long as the minimum dierential pressure across the valve is maintained, and for as long as there is voltage to the coil.
Figure 1: Function NC
2.2 Function NO
Coil voltage disconnected (closed)
When the voltage to the coil (8) is disconnected, the pilot orice (6) is open. As the pilot orice is larger than the equalizing orice (4), the pressure across the diaphragm (7) drops and therefore it is lifted clear of the main orice (5). The valve will be open for as long as the minimum dierential pressure across the valve is maintained, and for as long as the voltage to the coil is disconnected.
Coil voltage connected (open)
When voltage is applied to the coil, the valve plate (3) is pressed down against the pilot orice (6). The pressure across the diaphragm (7) is built up via the equalizing orice (4). The diaphragm closes the main orice (5) as soon as the pressure across the diaphragm is equivalent to the inlet pressure. The valve will be closed for as long as there is voltage to the coil.
© Danfoss | Climate Solutions | 2021.05 AI307038742363en-000302 | 3
1 2
3 4
5
8
6 7
12345678Armature
Opening spring
Valve plate
Equalizing orice
Main orice
Pilot orice
Diaphragm
Coil
Solenoid valve, Type EV221BW
Figure 2: Function NO
© Danfoss | Climate Solutions | 2021.05 AI307038742363en-000302 | 4