Data Sheet
Solenoid valve
Type EV220W
Indirect servo operated for compact installation in various applications
EV220W is a range of compact indirect servooperated 2/2 way solenoid valves with
connections from 3/8” to 2”, especially
designed for use within a limited space. This
range has been designed for use within various
markets, such as, the Industrial and HVAC
markets, which demand an easy and reliable
valve that is easy to setup and use.
Features and versions
• For water, oil, compressed air and similar
neutral media
• NBR for air and oil
• WRAS approved with EPDM sealing; 0 – 90 °C
NC version 0 – 50 °C NO version
• Standard equipped with clip on coil for dry
and humid environments
• Enclosure: IP65
AI236986440888en-001101

Dierential pressure range [bar]
Solenoid valve, Type EV220W
1 Portfolio overview
Table 1: Portfolio overview
© Danfoss | Climate Solutions | 2021.11 AI236986440888en-001101 | 2

Solenoid valve, Type EV220W
2 Functions
2.1 Function, NC
Coil voltage disconnected
When voltage is disconnected, the armature spring (2) presses the armature (3) down against the pilot orice (4).
Pressure builds up over the diaphragm (5) via the equalizing orice (6). The diaphragm closes the main orice (7) as
soon as the pressure over the diaphragm equals the inlet pressure. The valve stays closed for as long as voltage
remains disconnected.
Coil voltage connected (open)
When voltage is applied to the coil (1), the pilot orice (4) is opened. Since the pilot orice is larger than the
equalizing orice (6), pressure over the diaphragm (5) falls and the diaphragm is lifted clear of the main orice (7).
The valve stays open for as long as the required minimum dierential pressure is present and voltage is applied to
the coil.
Figure 1: Function, NC
© Danfoss | Climate Solutions | 2021.11 AI236986440888en-001101 | 3

Solenoid valve, Type EV220W
2.2 Function, NO
Coil voltage disconnected (Open)
When voltage is disconnected, the pilot orice (4) is opened. Since the pilot orice is larger than the equalizing
orice (6), pressure over the diaphragm (5) falls and the diaphragm is lifted clear of the main orice (7). The valve
stays open for as long as the required minimum dierential pressure is present and voltage is applied to the coil.
Coil voltage connected (Close)
When voltage is applied to the coil (1), the armature spring (2) presses the armature (3) down against the pilot
orice (4). Pressure builds up over the diaphragm (5) via the equalizing orice (6). The diaphragm closes the main
orice (7) as soon as the pressure over the diaphragm equals the inlet pressure. The valve stays closed for as long as
voltage remains disconnected.
Figure 2: Function, NO
© Danfoss | Climate Solutions | 2021.11 AI236986440888en-001101 | 4