Danfoss EM-PMI318B Data sheet

Data Sheet
EM-PMI318B + EC-C1200F
Electric Machine + Converter Systems
Formerly the UQM PowerPhase HD2 220(+), 250(+)
These Danfoss Editron machine + converter systems were specifically designed for heavy-duty commercial electric vehicle applications and provide more than 95% system efficiency.
These systems provide the highest continuous power and torque in their class.
Designed to meet the most rigorous applications for durability and functional safety, these systems are also a scalable design to future-proof the most diverse commercial EV/HEV/PHEV platforms.
This system is designed for pairing with various transmissions as well as integrated into eAxles for optimizing overall vehicle drive train efficiency, increased vehicle range, and total cost of ownership.
Features
Reduced size and increased power density
Unique, advanced PM synchronous machine
High efficiency (95% DC input to Shaft power out)
Increased Continuous power and torque capability
System specifications
EM-PMI318B-T440E-255V and EC-C1200F-1200 EM-PMI318B-T520E-465V and EC-C1200F-1200
Operating speed 0 - 6000 rpm 0 - 5500 rpm Maximum / continuous power Maximum / continuous torque 700 Nm / 440 Nm 1000 Nm / 520 Nm Peak efficiency 95% 95% Operating voltage 250-440 VDC 450-750 VDC Nominal voltage Communication CAN bus CAN bus
**
*
220 kW / 135 kW 250 kW / 180 kW
360 VDC 660 VDC
Fastest known speed sync for shifting transmissions
Designed for highest durability and functional safety
Graphical user interface and real time event logging
For more detailed information, visit
www.danfoss.com
*
Continuous ratings stated at 60° C inlet coolant
**
Nominal voltage is the voltage at which system specifications are stated
©
Danfoss | December 2020 AI362410058222en-000102 | 1
Data Sheet
EM-PMI318B + EC-C1200F
Converter description (EC-C1200F-1200)
Dimensions
Length 21.2 in 539 mm Width 16.0 in 408 mm Height 3.8 in 96 mm Weight 42 lb 19 kg
Converter performance
Operating voltage
EC-1200F-1200-440 EC-1200F-1200-750
Operating voltage input range
Minimum voltage 250 VDC 450 VDC Maximum voltage 440 VDC 750 VDC
250 - 440 VDC 450 - 750 VDC
Digital signal processor
Nominal input voltage 12 or 24 VDC Input supply voltage range 9 to 35 VDC Input supply current range 1 to 5 A
Liquid cooling system
EC-1200F-1200-440 EC-1200F-1200-750
Minimum coolant flow 10 l/min 50/50 water/
glycol
Maximum inlet temperature
140° F / 60° C 140° F / 60° C
10 l/min 50/50 water/ glycol
Inverter type
Control type Proprietary Power device IGBT Switching frequency 3 to 12 kHz