Protection class: IP65 Temperature class: F (155°C) Coolant: plain water with appropriate corrosion inhibitor Rated values for all motors are for 500 VAC terminal voltage
Motor type Rated power
(kW) coolant temp.
EM-PMI300-T310-1100 EM-PMI300-T310-1300 EM-PMI300-T310-1600 EM-PMI300-T310-2200 EM-PMI300-T310-2800 EM-PMI300-T310-3200 EM-PMI375-T200-2600 EM-PMI375-T500-1100 EM-PMI375-T500-1300 EM-PMI375-T500-1600 EM-PMI375-T500-1800 EM-PMI375-T500-2000 EM-PMI375-T500-2700 EM-PMI375-T500-3200 EM-PMI375-T800-900 EM-PMI375-T800-1300 EM-PMI375-T800-1600 EM-PMI375-T800-1900 EM-PMI375-T800-2300 EM-PMI375-T800-2800 EM-PMI375-T800-3200 EM-PMI375-T800-3800 EM-PMI375-T1100-1200 EM-PMI375-T1100-1800 EM-PMI375-T1100-2100 EM-PMI375-T1100-2400 EM-PMI375-T1100-2900 EM-PMI540-T1500-700 EM-PMI540-T1500-1200 EM-PMI540-T1500-1400 EM-PMI540-T1500-1600 EM-PMI540-T1500-1800 EM-PMI540-T1500-2400 EM-PMI540-T2000-1300 EM-PMI540-T2000-1700 EM-PMI540-T2000-2100 EM-PMI540-T3000-1300 EM-PMI540-T3000-1600 EM-PMI540-T4000-1600 EM-PMI540-T4000-2400
AM268549481597 en00-0109
41 45 352 391 745 1100 2200 48 55 352 406 746 1300 2600 58 66 346 392 746 1600 3200 78 90 339 391 746 2200 4000 / 4400*** 91 107 311 363 697 2800 4000 / 5600***
112 131 334 390 696 3200 4000 / 6000***
48 56 175 203 500 2600 4000 55 62 478 542 1490 1100 2200 71 77 521 567 1480 1300 2600 85 96 508 574 1450 1600 3200
95 111 507 590 1400 1800 3600 104 119 498 569 1200 2000 4000 140 163 497 576 1194* 2700 4000 150 177 449 528 1038* 3200 4000
83 93 882 986 2280 900 1800 110 123 805 905 2200 1300 2600 139 156 828 931 2280* 1600 3200 165 186 831 933 2280* 1900 3800 189 213 787 887 2040* 2300 4000 226 261 773 891 1880* 2800 4000 260 298 778 892 1700* 3200 4000 297 343 747 860 1400* 3800 4000 147 168 1167 1340 2900* 1200 2400
202 232 1075 1230 2500* 1800 3600 233 271 1062 1233 2170* 254 300 1013 1194 2000* 274 332 904 1094 1600* 2900 4000 107 121 1454 1657 2900 700 1400 184 212 1468 212 246 1445 1680 2580* 1400 2800 232 269 1382 1604 2586* 1600 3200 265 311 1405 1650 2286* 1800 3600 326 433 1300 1546 2075* 2400 4000 285 326 2092 2394 3700* 1300 2600 345 406 1940 2282 2954* 1700 3400 401 474 1826 2156 2774* 2100 4000 344 401 2523 2944 3914* 1300 2600 397 474 2369 2828 3155* 1600 3200
724 (+40°C) 4319 (+40°C) 5000** 1600 3200 841 (+40°C) 3346 (+40°C) 4050** 2400 4000
Rated torque (Nm) coolant temp.
1690 2589* 1200 2400
Maximum Torque (Nm)
Rated Speed (Rpm)
2100 4000 2400 4000
Maximum Speed (Rpm)+65°C +40°C +65°C +40°C
© Danfoss | August 2018
**QUAD peak torque achieved with 4 EC-C inverters
Information subject to change without further notice
***With the standard bearings 4000 rpm, higher speeds are possible with grease lubricated bearings (BHS)
Fact Sheet
EC-C1200-450 Electric Converter
Protection class: IP67 Operation tempe Coolant: plain water with appropriate corrosive inhibitor Coolant temperature: 65°C Dimensions: (weight, length, depth, height) 15 kg, 482 x 244 x 109 mm DC voltage range: Nominal DC voltage: 750VDC AC voltage range:
rature: -40…105°C
0-850VDC
0-560VAC
Type example Nominal power, kW
EC-C1200-450-L+MC120+AFE120+UG120 EC-C1200-450-L+MC180+AFE180+UG180
EC-C1200-450-L+MC240+AFE240+UG240 EC-C1200-450-L+MC350+AFE350+UG300 EC-C1200-450-L+MC350+AFE350+UG350
*Coolant temperature: +40°C
Type example Nominal power, kW** Nominal current, Adc
EC-C1200-450-L+DC150 EC-C1200-450-L+DC250 EC-C1200-450-L+DC300 EC-C1200-450-L+DC400
**LV-side voltage 600 VDC, HV-side voltage: 750 VDC +DC option needs EC-LTS1200-400 unit, see below
100 150 200 250 300*
90 150 180 240
AC current, Arms
120 180 240 300 350*
150 250 300 400
EC-LTS1200-400 Inductor Unit
Protection class: IP65 Operation temperature: -40…85°C Coolant: plain water with appropriate corrosive inhibitor Coolant temperature: 65°C Dimensions: (weight, length, depth, height) 58 kg, 665 x 200 x 308 mm
AM268549481597 en00-0109
Information subject to change without further notice