Danfoss EM-PME375-T200 Data sheet

Data Sheet
EM-PME375-T200
Electric machine, permanent magnet external
FEATURES
Synchronous Reluctance assisted Permanent
Magnet (SRPM) technology
Extremely compact and robust structure
Highest efficiency throughout the operation range
on the market (~96 %)
Liquid cooled with plain water or water/glycol
mixture
Low coolant flow required
Allowed coolant temperature up to +65°C
Up to IP65 enclosure class to maximize reliability
Multiple mounting possibilities
GENERATOR SPECIFIC FEATURES
Standard SAE flange mounting to match the diesel
engine connection
Wide
Can be also used as starter motor for the ICE
selection of speed ratings allowing the
generator to be selected to customer specific
applications with various voltage requirements
MOTOR SPECIFIC FEATURES
Extended speed and torque capabilities compared
to standard PM motors from Danfoss reluctance
assisted permanent magnet motor technology
Motor structure is designed to be able to produce
high starting torque: EM-PME motor can produce
instantly full torque to a non-rotating shaft
Optimized speed range to meet the most common
gear ratios used in heavy mobile machinery
GENERAL
The machine is developed especially for demanding applications. The design of these machines makes them smaller, lighter and more efficient than conventional products on the market.
The machine is designed to be shorter than normal motors for applications where axial length is crucial parameter. The machine is designed to be connected directly to the ICE flywheel housing with part of the motor being inside the flywheel housing further shortening the length of the motor.
TYPICAL APPLICATIONS
Generator for diesel-electric/serial hybrid
applications
Traction/propulsion motor
Generator/Motor for parallel hybrid applications
1 | © Danfoss | April 2020 AI312651107941en-000103
Data Sheet
General electrical properties
Nominal voltage (line to line)
500 VAC
Voltage stress
IEC 60034-25, Curve A: Without filters for motors up to 500 VAC
Nominal efficiency
96 %
Pole pair number
10
Power supply
Inverter fed.
Minimum inverter switching frequency
8 kHz
Basic information
Machine type
Synchronous reluctance assisted permanent magnet
Mounting direction
Can be used in any direction, see user guide for details.
Mounting
IM 3001 (Flange)
Standard Flange D-end (SAE J617)
SAE 3, transmission housing Standard Flange N-end
SAE 3, flywheel housing
Standard rotation direction
Clockwise (both directions possible)
Protection class (IEC 60034-5)
Up to IP65
Duty type (IEC 60034-1)
S9
Standard color
Dark grey RAL7024 powder coating
Mechanical
Total weight
85 kg (no options)
Moment of inertia
0.77 kgm²
Rotating mass
27 kg
Dimensions
Length (frame)
66 mm
Diameter (frame)
451 mm
Total length (frame + shaft)
215.6 mm
Cooling
Cooling liquid
Plain water with appropriate
corrosive inhibitor)
Cooling liquid corrosive inhibitor type
Ethylene glycol Glysantin G48 recommended
Cooling method (IEC 60034-6)
IC 71 W
Minimum cooling liquid flow
20 l/min
Pressure loss
0.3 bar with 20 l/min (+25°C coolant)
Cooling liquid temperature max
+65°C (Derating required if exceeded)
Temperature rating
Insulation class (IEC 60034-1)
H (180°C)
Temperature rise (IEC 60034-1)
85°C
Maximum winding temperature
150°C
Nominal ambient
(IEC 60034-1)
65°C Min. ambient temperature
-40°C
Nominal altitude (IEC 60034-1)
1000 m
Connections
Coolant connection
2 x G1/2 bores
HV cables
3 x 50 mm2 max.
Cable direction
Cable direction radial with straight
standard angle connector
HV cable connector
3x AMPHENOL HVBI005R10AMHARD
HV cable mating
3 x AMPHENOL HVBI-7-05R10-XFC-
connector manufacturer)
HV cable
Recommended H+S Radox screened cable
LV connector
12 pin TE HDSCS
LV connector type
TE 1-1564520-1
LV connector pin type
Gold plated
LV mating connector type
TE 1-1703639-1
LV mating connector
TE 1241380-2 (Gold plated)
LV connector pin configuration
See Table below
EM-PME375-T200

SPECIFICATIONS

temperature
(IEC 60034-7)
connector and towards N-end with
connector
XXXX-FG/PC (straight plug) 3x AMPHENOL HVBI-9-05R10-XFC­XXXX-FG/PC (right angle plug) (check the exact codes form
2 | © Danfoss | April 2020 AI312651107941en-000103
corrosive inhibitor (max. 50 %
pin type
Data Sheet
PIN
Description
1
Resolver, RES_COSN
2
Resolver, RES_SINN
3
Resolver, EXCN
4
Temperature, PT100, windings
5
Temperature, PT100, windings
6
Temperature, PT100, windings
7
Resolver, RES_COSP
8
Resolver, RES_SINP
9
Resolver, EXCP
10
Temperature, PT100, windings GND
11
Temperature, PT100, windings GND
12
Temperature, PT100, windings GND
Coolant temperature +65°C
Coolant temperature +40°C
Coolant temperature +40 / +65°C
Cont.
Cont.
Nom.
Nom.
Nom.
Coolant temperature +65°C
Coolant temperature +40°C
Coolant temperature +40 / +65°C
Volt/
[V/rpm]
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0 5 10 15 20 25 30 35
Pressure loss [bar]
Volume flow [l/min]
EM-PME375-T200
Table 1 Pin configuration of LV-connector

PRESSURE LOSS VS COOLANT FLOW

Picture 1 Pressure loss vs coolant flow

MOTORS

Type
EM-PME375-T200-1500 191 30 37.5 191 30 38 1500 3000 800
EM-PME375-T200-1800 180 36 45 210 40 53 1800 3600 800
EM-PME375-T200-2300 184 48 60 208 50 68 2300 4000 800
EM-PME375-T200-2600 172 50 63 200 54 73 2600 4000 800
(* Peak torque achieved with one (350A) inverter (** Peak torque achieved with two (350A) inverter

GENERATORS

Type
EM-PME375-T200-1500 32 31 36.5 31 31 36 1575 262.5 0.99 0.367
EM-PME375-T200-1800 38 37 44 44 42 51 1890 315.0 0.96 0.298
EM-PME375-T200-2300 50 49 58 57 55 65 2415 402.5 0.96 0.229
EM-PME375-T200-2600 53 52 62 61 58 71 2739 456.5 0.95 0.206
(*** Back EMF for cold (20 °C) generator
3 | © Danfoss | April 2020 AI312651107941en-000103
Torque
[Nm]
Apparent
power
[kVA]
Power
[kW]
Cont.
power
[kW]
Current
[A]
Nom.
Current
[A]
Cont. Torque
[Nm]
Apparent
power
[kVA]
Cont. Power
[kW]
Cont. Power
[kW]
Current
[A]
Nom.
Current
[A]
speed
[rpm]
Nom.
speed
[rpm]
Max. speed
[rpm]
Nom. Freq.
[Hz]
Power
factor
Peak torque
[Nm]
speed
ratio
Data Sheet
EM-PME375-T200

Integrated machine is commonly connected directly to the diesel engine flywheel housing. In such application, part of the motor is inside the diesel engine. Exploded view of this kind of application is shown below.

Picture 2 Integrated machine connected to diesel engine flywheel housing
4 | © Danfoss | April 2020 AI312651107941en-000103
Data Sheet
EM-PME375-T200

PRODUCT CODE AND OPTIONS

Use product code including all needed options for ordering. Standard options do not need to be listed in the code as they are selected by default if a non-standard option is not selected. Standard options are indicated by a star (*).

Product code Description

EM-PME375-T200-1800 Standard unit with standard options EM-PME375-T200-1800+RES1 Standard unit otherwise but with resolver angle sensor
Table 2 Product code examples

Variant Code Description Additional information

High voltage connector * High voltage plug-in connectors

for 50 mm

+HVC1

Rotation sensor * None No resolver

+RES1

*Standard option

High voltage plug-in connectors for 35 mm2 cables

Resolver

2
cables

One plug-in connector per phase for 50 mm2 cable

One plug-in connector per phase for 35 mm2 cable

In-built non contacting resolver, 5-pole pair

Table 3 Option list
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
5 | © Danfoss | April 2020 AI312651107941en-000103
Loading...