Data Sheet
Danfoss ECmat™ Aqua
Hot-water fl oor heating mat
Application
Ordering
Danfoss ECmat Aqua is a hot-water oor heating
mat with low construction height (approximately
10 mm), which makes it especially suitable for renovation jobs in existing buildings.
The capacity of your Danfoss ECmat Aqua installation is strongly dependent on the capacity of the
circulation pump. Please consult your plumber to
determine the capacity of your heating system.
Each room with oor heating should be equipped
with its own thermostatic room temperature control, such as a Danfoss RTL valve with TH function
(not included).
Product Code no.
Danfoss ECmat™ Aqua, 088L9280
Manifold for one mat 088L9282
Manifold for two mats 088L9284
Manifold for three mats 088L9286
Repair kit 088L9288
Technical speci cations
Width 50 cm
Length 6 m
Height 8 mm
Extra pipe for return ow 7 m
Adheisive mesh Yes
Colour Blue
Pipe type PE-RT (5 layered pipe)
Oxygen Permeability according to DIN 4726
Certi ed according to DIN 4721 and DIN 16833
Warranty (pipe) 10 years
VDHWA102
© Danfoss | FHE | 2015.10 | 1
Data Sheet Danfoss ECmat™ Aqua
3 m² oor area
Only oor heating
Mixed systems
New build
Numbers Item no. Description
1 pcs 088L9280 Danfoss ECmat Aqua
1 pcs 088L9282 Manifold for one mat
1 pcs 003L1015
1 pcs 003L10 40 FJVR return temperature limiting sensor
1 pcs 088L9280 Danfoss ECmat Aqua
1 pcs 088L9282 Manifold for one mat
1 pcs 003L1001
1 pcs 013G2990
1 pcs 088L9280 Danfoss ECmat Aqua
1 pcs 088L9282 Manifold for one mat
1 pcs 003L1000 FHV-R set: return temperature limiter valve
1 pcs 003L10 40 FJVR return temperature limiting sensor
FHV-R set: return temperature limiter valve
with air vent, bleed key and drain tap
FHV-R set: return temperature limiter valve
with air vent, bleed key and drain tap
RA 2000 room sensor with frost protection,
limiting and locking of temperature set-point
with air vent, bleed key and drain tap
6 m² oor area
Only oor heating
Mixed systems
New build
Numbers Item no. Description
2 pcs 088L9280 Danfoss ECmat Aqua
1 pcs 088L9284 Manifold for two mats
1 pcs 003L1015
1 pcs 003L10 40 FJVR return temperature limiting sensor
2 pcs 088L9280 Danfoss ECmat Aqua
1 pcs 088L9284 Manifold for two mats
1 pcs 003L1001
1 pcs 013G2990
2 pcs 088L9280 Danfoss ECmat Aqua
1 pcs 088L9284 Manifold for two mats
1 pcs 003L1000 FHV-R set: return temperature limiter valve
1 pcs 003L10 40 FJVR return temperature limiting sensor
FHV-R set: return temperature limiter valve
with air vent, bleed key and drain tap
FHV-R set: return temperature limiter valve
with air vent, bleed key and drain tap
RA 2000 room sensor with frost protection,
limiting and locking of temperature set-point
with air vent, bleed key and drain tap
2 | © Danfoss | FHE | 2015.10
VDHWA102