Danfoss ECmat Aqua Operating guide

0 (0)

Installation Guide

Danfoss ECmat Aqua

electricheating.danfoss.com

Installation Guide

Danfoss ECmat Aqua

 

 

 

 

 

 

Table of Contents

 

 

1

Product specifications

 

3

 

1.1

Potential application examples

3

2

Installation instructions

5

2.1Initial planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.2

Preparation and cleaning

5

2.3

Laying the mat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

2.4

Intermediate test

7

2.5

Covering & final test

8

2 | Danfoss © | 2015.09

VIEGG102

Installation Guide

Danfoss ECmat Aqua

 

 

1

Product specifications

Danfoss ECmat Aqua is a hot-water floor heating mat with low construction height (approximately 10 mm), which makes it especially suitable for renovation jobs in existing buildings.

The capacity of your Danfoss ECmat Aqua installation is strongly dependent on the capacity of the

circulation pump. Please consult your plumber to

UK

determine the capacity of your heating system.

 

Each room with floor heating should be equipped with its own thermostatic room temperature control, such as a Danfoss RTL valve with TH function (not included).

1.1Potential application examples

Substrate

Timber flooring (parquet, boarding) or on existing thermal insulation

Surface

 

 

 

 

 

 

Load distribution mat,

 

Construction height

 

Laid in staggered

Floor leveling compound

min. 9 mm, glued (not

 

min. 13 mm, including

 

 

 

sections

 

screwed)

 

pipe

 

 

 

 

 

 

 

 

 

 

 

 

Load distribution mat,

 

Construction height

 

Laid in staggered

Anhydride screed

min. 9 mm, glued (not

 

min. 28 mm, including

 

 

 

sections

 

screwed)

 

pipe

 

 

 

 

 

 

 

 

 

 

 

Substrate

 

Screed, concrete, stone, etc.

 

Surface

 

 

 

 

 

 

 

 

 

 

Construction height

 

Laid in staggered

Floor leveling compound

Primer

 

min. 13 mm, including

 

 

 

sections

 

 

 

pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Construction height

 

Laid in staggered

Anhydride screed

Primer

 

min. 28 mm, including

 

 

 

sections

 

 

 

pipe

 

 

 

 

 

 

 

 

 

 

 

Please note!

 

 

• Proper thermal insulation of the substrate

• Consult your plumber for any work on your

enhances the performance of Danfoss ECmat

Aqua. Take suitable measures before instal-

existing heating system. They have the

lation.

necessary experience and will be pleased to

 

assist you

 

Remember to fit expansion joints at the junctions of heated and unheated areas

Danfoss © | 2015.09

VIEGG102 | 3