Installation Guide
Danfoss ECmat Aqua
electricheating.danfoss.com
Installation Guide Danfoss ECmat Aqua
Table of Contents
1 Product specications � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
2 Installation instructions � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5
1.1 Potential application examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 Initial planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Preparation and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Laying the mat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.4 Intermediate test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.5 Covering & nal test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2
| Danfoss © | 2015.09 VIEGG102
Installation Guide Danfoss ECmat Aqua
1 Product specications
Danfoss ECmat Aqua is a hot-water oor heating
mat with low construction height (approximately
10mm), which makes it especially suitable for
renovation jobs in existing buildings.
The capacity of your Danfoss ECmat Aqua installation is strongly dependent on the capacity of the
1�1 Potential application examples
Substrate
Surface
Floor leveling compound
Anhydride screed
Substrate
Surface
Floor leveling compound Primer
Anhydride screed Primer
Timber ooring (parquet, boarding) or on existing thermal insulation
Load distribution mat,
min. 9mm, glued (not
screwed)
Load distribution mat,
min. 9mm, glued (not
screwed)
circulation pump. Please consult your plumber to
determine the capacity of your heating system.
Each room with oor heating should be
equipped with its own thermostatic room temperature control, such as a Danfoss RTL valve
with TH function (not included).
Construction height
min. 13mm, including
pipe
Construction height
min. 28mm, including
pipe
Screed, concrete, stone, etc�
Construction height
min. 13mm, including
pipe
Construction height
min. 28mm, including
pipe
Laid in staggered
sections
Laid in staggered
sections
Laid in staggered
sections
Laid in staggered
sections
UK
Please note!
• Consult your plumber for any work on your
existing heating system. They have the
necessary experience and will be pleased to
assist you
• Remember to t expansion joints at the junctions of heated and unheated areas
Danfoss © | 2015.09 VIEGG102 |
• Proper thermal insulation of the substrate
enhances the performance of Danfoss ECmat
Aqua. Take suitable measures before installation.
3
Installation Guide Danfoss ECmat Aqua
Plan: Date:
0,5 м
4
| Danfoss © | 2015.09 VIEGG102