Danfoss EC-LTS1200-410 Data sheet

Data Sheet
EC-LTS1200-410
Liquid cooled heavy duty inductor unit
FEATURES
Extremely compact design: 410 A unit only 23 kg High enclosure class IP67 – sealed from moisture
and dust
Liquid cooled with plain water or water/glycol
mixture
Ambient temperature up to +105 °C and down to
-40 °C
Allowed coolant temperature up to +65 °C Robust design withstanding high levels of
mechanical vibrations and shocks
Designed especially for highly cyclical loads typical
in heavy mobile work machines
Three temperature sensors included for
temperature surveillance
GENERAL
The device is a heavy duty external inductance unit designed to be combined with EC-C1200 DC/DC-converter. It allows flexible positioning of the DC/DC-converter and inductor unit and is used to transfer energy between two different voltage levels.
Typical applications:
Boosting battery voltage to higher DC-link voltage Charging high voltage batteries from higher DC-link
voltage
1 | © Danfoss | June 2021 AI273944143869en-000104
Data Sheet
Inductance per
165 µH (at nominal current)
Minimum cooling
10 l/min
Mechanical vibration
10 G
58…150 Hz: 1 G
HV cable glands
(with
3x
Pflitsch blueglobe
TRI bg
Recommended cable
35 mm
: Druseidt
with narrow
EC-LTS1200-410
SPECIFICATIONS
DC connection
DC link voltage range 0-850 VDC
DC link nominal voltage
Nominal current 410A total (65 °C coolant, 8 kHz
inductor
Mechanical
Dimensions (WxHxL, mm)
Weight 23 kg
750 VDC
interleaved switching frequency)
403x147x262 403x147x287 (with +CG1 option)
Mechanical shock 50 G
Connections
5…24.9 Hz: +-1.6 mm
24.9…100 Hz: 4G (sinusoidal)
ISO 16750-3
4.2.2 Test for devices on rigid points on the body and on the frame Notes:
acceleration: 500 m/s2; duration: 6 ms; number of shocks: 10 per
test direction (x, y and z axis, both directions, 6x directions in total).
30 G, CEI EN 61373 category 2
Cooling
Cooling liquid Plain water with appropriate
Cooling liquid glycol type
liquid flow
Maximum continuous pressure
Pressure loss 40 mbar with 10l/min
Cooling liquid temperature
corrosive inhibitor (max. 50 % corrosive inhibitor)
Ethylene glycol (Glysantin G48 recommended)
2 bar
(+25°C coolant)
-40°C …+65°C
Ambient Conditions
Storage temperature -40°C…105°C
Operating temperature
Altitude max. 4000 m
Relative humidity 100 %
Enclosure class IP67
-40°C…105°C (with nominal coolant temp.)
ISO 16750-3 Test VII – Commercial vehicle, sprung masses – Table 12 Notes: test duration 8h axis (three axis tested; x,y and z axis) total spectral acceleration 5,91 G
5 G, CEI EN 61373 category 2
IEC 60068-2-6 (2007-12, Test Fc) 10…57 Hz: amplitude
0.075mm
rms
Coolant connection 2 x G3/4” coolant hose
connector
HV cable recommended type
HV cable cross section ɊNN2 (Cu) (M25 cable gland)
+CG1)
HV cable lug size 35-8, 50-8, 70-8, 95-8, 120-8
lug
Temperature measurement
Temperature sensor connector + insert + pins
Temperature sensor mating connector + insert + socket
HUBER+SUHNER Radox Elastomer S screened automotive cable
www.hubersuhner.com
ɊNN2 (Cu) (M32 cable gland)
225ms tri 3x Pflitsch blueglobe TRI bg 232ms tri 2x M32 plugs Configurable cable glands, see Table 3
2
flange 03901 50 mm2: Druseidt with narrow flange 03903 70 mm2: Druseidt with narrow flange 03906 95 mm2: Druseidt with narrow flange 03910 (Only compatible with M32 cable gland) 120 mm2: Druseidt with narrow flange 03914 (Only compatible with M32 cable gland)
www.druseidt.de
3x PT100 temperature sensors, one per inductor
M16 male, 7.840.200.000 Insert 10-pole, 7.003.910.101 Sensor Connector Pin,
7.010.981.001
www.hummel.com
M16 female, 7.810.400.000 Insert 10-pole, M16, RCPT,
7.003.910.102 Sensor Connector Socket,
7.010.981.002
www.hummel.com