Data Sheet
YEAR
WARRANTY Product
Product specifications
ECiceguard 18 Ready-made
The ECiceguard is readymade self-limiting parallel heating cable that is used for ice and snow melting on roofs, in gutters and downpipes (UV-resistant).
ECiceguard heating cables should not be in direct contact with bitumen.
The self-limiting capability of the cable ensures that the output of the cable increase or decrease according to ambient temperature.
The heating cable is flexible and easy to install as it can be cut to length at site and installed directly on to the roof and gutter system.
All self-limiting heating cables must be over-temperature protected by a thermostat, as the output will decrease, but never be zero, and be protected by a RCD with a maximum trip current of 30 mA.
Benefits |
Nominal voltage |
230 V AC |
|||
|
• Easy to install |
Nominal output |
18 W/m @ 10 °C |
||
|
• Cut to length on site |
|
|
||
|
Output tolerance (min-max) |
19 - 25 W/m @ 10 °C |
|||
|
• Ready-made lengths |
|
|
||
|
Maximum permissible use temperature |
65 °C, powered |
|||
|
|
|
|
85 °C, unpowered |
|
Approvals: |
Minimum installation temperature |
-5 °C |
|||
|
|
|
Cable dimensions |
13,2 X 6,1 ± 0,3 mm |
|
|
|
|
|
|
|
|
|
|
Outer sheath |
Black UV protected, TPE |
|
|
|
|
|
|
|
|
|
|
Minimum braid coverage |
70% |
|
|
|
|
|||
|
|
|
|
|
|
Standard compliance: |
Maximum resistance protective braid |
10 Ω/Km |
|||
|
|
||||
Cold lead |
5 m DTCL, 3G 1,5mm² |
||||
|
• SS 4242411 |
||||
|
|
|
|||
Bending Ø, min. |
64 mm (Ø to the inside of the cable) |
||||
|
|
|
|||
|
|
|
|
|
|
|
|
|
IP Class |
IPX7 |
|
|
|
|
|
|
Types: ECiceguard 18 Ready-made
Item no. |
Cable length |
Nominal output @ 10 °C |
Cold lead |
EAN no. |
|
|
|
|
|
088L6575 |
2 m |
36 W |
5 m |
5703466247020 |
|
|
|
|
|
088L6576 |
4 m |
72 W |
5 m |
5703466247037 |
|
|
|
|
|
088L6577 |
6 m |
108 W |
5 m |
5703466247044 |
|
|
|
|
|
088L6578 |
8 m |
144 W |
5 m |
5703466247051 |
|
|
|
|
|
088L6579 |
10 m |
180 W |
5 m |
5703466247068 |
|
|
|
|
|
088L6580 |
15 m |
270 W |
5 m |
5703466247075 |
|
|
|
|
|
088L6581 |
23 m |
414 W |
5 m |
5703466247082 |
|
|
|
|
|
088L6582 |
30 m |
540 W |
5 m |
5703466247099 |
|
|
|
|
|
088L6583 |
50 m |
900 W |
5 m |
5703466247105 |
|
|
|
|
|
Construction
Over jacket |
|
|
|
|
• |
Nickel plated copper bus wires |
|
Screen |
• |
Radiation Cross-Linked Semiconductive Heating Matrix |
|
• |
Radiation Cross-Linked Primary Dielectric Insulation |
||
|
|||
Insulation |
• |
Tinned copper braid |
|
|
• |
Polyolefin over jacket |
|
Self limiting heating element |
|
Bus wires, 1,25 mm² |
Electrical heating · ©Danfoss |
AI281660310070en-010106 |
Maximum heating circuit length on a pipe, with circuit breaker with C-characteristic*
Switch on |
Power W/m |
|
|
ECiceguard 18 |
|
|
||
temperature |
10 A |
16 A |
20 A |
25 A |
32 A |
|||
|
||||||||
10 °C |
20 |
55 |
88 |
110 |
135 |
135 |
||
0 °C ice water |
36 |
40 |
64 |
80 |
100 |
105 |
||
-10 |
°C |
42 |
36 |
58 |
72 |
90 |
100 |
|
-20 |
°C |
48 |
33 |
52 |
65 |
81 |
100 |
|
-30 |
°C |
54 |
29 |
46 |
57 |
71 |
90 |
|
-40 |
°C |
61 |
25 |
40 |
50 |
62 |
80 |
* Maximum length in ice water or for roof applications is 2 times lower.
Power output characteristic
Output of heating cable installed and measured on a pipe.
|
|
|
W/m |
|
|
|
|
|
|
|
40 |
|
|
|
|
|
|
|
35 |
|
ECiceguard 18 Ready-made |
|
|
|
|
|
|
DEVIiceguard™ 18 (G) Ready-made |
|
||
|
|
|
30 |
|
|
|
|
|
|
|
25 |
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
15 |
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
0 |
|
|
|
|
-60 |
-40 |
-20 |
0 |
20 |
40 |
60 |
80 |
Pipe temperature (°C)
Electrical heating · ©Danfoss |
AI281660310070en-010106 |