Danfoss ECiceguard 18 Data sheet

Product
YEAR
WARRANTY
Data Sheet
Product specifications
ECiceguard 18 Ready-made
The ECiceguard is readymade self-limiting parallel heating cable that is used for ice and snow melting on roofs, in gutters and downpipes (UV-resistant).
ECiceguard heating cables should not be in direct contact with bitumen. The self-limiting capability of the cable ensures that the output of the cable increase or
decrease according to ambient temperature. The heating cable is flexible and easy to install as it can be cut to length at site and
installed directly on to the roof and gutter system. All self-limiting heating cables must be over-temperature protected by a thermostat,
as the output will decrease, but never be zero, and be protected by a RCD with a maximum trip current of 30 mA.
Benefits
• Easy to install
• Cut to length on site
• Ready-made lengths
Approvals:
Standard compliance:
• SS 4242411
Types: ECiceguard 18 Ready-made
Item no. Cable length Nominal output @ 10 °C Cold lead EAN no.
088L6575 2 m 36 W 5 m 5703466247020 088L6576 4 m 72 W 5 m 5703466247037 088L6577 6 m 108 W 5 m 5703466247044 088L6578 8 m 144 W 5 m 5703466247051 088L6579 10 m 180 W 5 m 5703466247068 088L6580 15 m 270 W 5 m 5703466247075 088L6581 23 m 414 W 5 m 5703466247082 088L6582 30 m 540 W 5 m 5703466247099 088L6583 50 m 900 W 5 m 5703466247105
85 °C, unpowered Minimum installation temperature -5 °C Cable dimensions 13,2 X 6,1 ± 0,3 mm Outer sheath Black UV protected, TPE Minimum braid coverage 70% Maximum resistance protective braid 10 Ω /Km Cold lead 5 m DTCL, 3G 1,5mm² Bending Ø, min. 64 mm (Ø to the inside of the cable) IP Class IPX7
Construction
Over jacket
Screen
Insulation
Self limiting heating element
Bus wires, 1,25 mm²
Electrical heating · ©Danfoss AI281660310070en-010106
Nickel plated copper bus wires
Radiation Cross-Linked Semiconductive Heating Matrix
Radiation Cross-Linked Primary Dielectric Insulation
Tinned copper braid
Polyolefin over jacket
Maximum heating circuit length on a pipe, with circuit breaker with C-characteristic*
W/m
-60
Pipe temperature (°C)
Switch on
temperature
Power W/m
10 A 16 A 20 A 25 A 32 A
10 °C 20 55 88 110 135 135
0 °C ice water 36 40 64 80 100 105
-10 °C 42 36 58 72 90 100
-20 °C 48 33 52 65 81 100
-30 °C
54 29 46 57 71 90
-40 °C 61 25 40 50 62 80
* Maximum length in ice water or for roof applications is 2 times lower.
ECiceguard 18
Power output characteristic
Output of heating cable installed and measured on a pipe.
40
35
30
25
20
15
10
5
0
-40 -20 0 20 40 60 80
ECiceguard 18 Ready-made
DEVIiceguard™ 18 (G) Ready-made
AI281660310070en-010106Electrical heating · ©Danfoss