Danfoss ECA 35 Data sheet

Data sheet
ECA 35
Input / output extension module for ECL Comfort 310 / 310B
Description
ECA 35
Designed in Denmark
Application example
The ECA 35 module ex tends the ECL Comfort 310/ 310B with a number of inputs and outputs.
ECA 35 is used in ECL Comfort 310 related applications where the demand for extra inputs / outputs is present.
ECA 35 offers:
• 4 outputs, PWM*
• 3 outputs, 0 - 10 Volt
• 4 relay outputs
• 2 inputs (Pt 1000, digital or 0 - 10 Volt)
• 2 pulse inputs
* PWM = Pulse Width Modulation
ECA 35 is to be placed in the base part for ECL Comfort 310 / 310B.
The connection between the ECL Comfort 310 / 310B and ECA 35 is a 10-pole (2 x 5) connector.
A similar module, ECA 32, exists. The ECL Comfort 310 / 310B works with either one ECA 32 or one ECA 35.
The connection is automatically established when the ECL Comfort 310 / 310B is placed on the base part.
The PWM control principle can be used for speed control of for example circulation pumps.
© Danfoss | 2018.03
The example shows an advanced buffer control for heating: A319. The charging pump P2 / V2 and the circulation pump P3 / V3 can be speed controlled in two different ways: With 0 - 10 Volt (ECA 32 or ECA 35) or PWM controlled (ECA 35).
The shown diagram is a fundamental example and does not contain all components that are necessary in a system. All named components are connected to the ECL Comfort 310 and ECA 32 / 35.
VD.JM.A3.02 | 1
ECA 35 input / output extension module for ECL Comfort 310 / 310B
Ordering
Operation
Communication
General data
Typ e Designation Code no.
ECA 35 Internal module for ECL Comfort 310 / 310B.
Base part for ECL Comfort 310 / 310B (space for ECA 35)
ECA 35 is controlled from ECL Comfort 310 / 310B.
ECA 35 has a 10-pole female connector which automatically connects to the ECL Comfort 310 / 310B.
Ambient temperature 0 - 55 °C
Storage and transportation temperature -40 - 70 °C
Mounting In ECL Comfort 310's base part
Power supply From ECL Comfor t 310 / 310B via 10-pole female connector
Number of configurable inputs 2 (S11 and S12)
Configurable input types Each input is configured at application upload as Pt 1000, 0 -10 V or digital
Number of PWM outputs 4 (PWM Out 1 - 4)
PWM output frequency 200 Hz
PWM output Push-pull, pull-up to 12 Volt. See PWM output, principle sketch
PWM range 0 - 100 %
Max. load on each PWM output 10 mA
Number of relays 2 x SPST
Max. load on relay outputs 4 (2) A (4 A for ohmic load, 2 A for induc tive load)
Number of pulse counter inputs 2
Max. frequency of pulse counter input 200 Hz
Number of analogue outputs ( 0 -10 V) 3
Max. load on analogue output 2 mA each (min. resistance 5 KΩ)
Compatibility with ECL Comfort 310 / 310B From version 1.20 and up
Mounting guide (no text) is included
For mounting on wall or DIN rail (35 mm). Mounting guide (no text) and cable inlet accessories are included.
input. If an input is not configured at application upload, the default setting is “Pt 1000”. Configuration can also be done by using the ECL Portal or ECL Tool.
2 x SPDT
087H3205
087H3230
PWM output, principle sketch
2 | © Danfoss | 2018.03
VD.JM.A3.02
ECA 35 input / output extension module for ECL Comfort 310 / 310B
Connection terminals
Position in base part
Wiring example, relay outputs
VD.JM.A3.02
© Danfoss | 2018.03 | 3