Data sheet
ECA 32
Input / output extension module for
ECL Comfort 310 / 310B
Description
ECA 32
The ECA 32 module extends the ECL Comfort 310
/ 310B with a number of inputs and outputs.
ECA 32 is used in ECL Comfort 310 related
applications where the demand for extra inputs
/ outputs is present.
ECA 32 is to be placed in the base part for ECL
Comfort 310 / 310B.
Designed in Denmark
The connection between the ECL Comfort 310 /
310B and ECA 32 is a 10-pole (2 x 5) connector.
The connection is automatically established when
the ECL Comfort 310 / 310B is placed on the base
part.
Application example
M1, M2, M3 and V3 are controlled via ECA 32
S12, F1 and F2 are inputs via ECA 32
The shown diagram is a fundamental example
and does not contain all components that are
necessary in a system.
All named components are connected to the
ECL Comfort controller / ECA 32.
© Danfoss | 2018.03
VD.GU.A4.02 | 1
Data sheet ECA 32 input / output extension module for ECL Comfort 310 / 310B
Ordering
Operation
Communication
General data
Connection terminals
Typ e Designation Code no.
ECA 32 Internal module for ECL Comfort 310 / 310B.
Base part for ECL Comfor t 310 /
310B (space for ECA 32)
ECA 32 is controlled from ECL Comfort 310 / 310B.
ECA 32 has a 10-pole female connector which automatically connects to the ECL Comfort 310 / 310B.
Ambient temperature 0 - 55 °C
Storage and transportation temperature -40 - 70 °C
Mounting In ECL Comfort 310's base part
Number of inputs 6
Input types Each input is configured at application upload as Pt 1000, 0-10 V or digital
Number of relays 2 x SPST
Max. load on relay outputs 4 (2) A (4 A for ohmic load, 2 A for inductive load)
Number of pulse counter inputs 2
Max. frequency of pulse counter input 200 Hz
Number of analogue outputs ( 0 -10 V) 3
Max. load on analogue output 2 mA each (min. resistance 5 KΩ)
Compatibility with ECL Comfort 310 / 310B From version 1.20 and up
Mounting guide (no text) is included
For mounting on wall or DIN rail (35 mm). Mounting guide (no text) and cable
inlet accessories are included.
input
2 x SPDT
087H3202
087H3230
Position in base part
2 | © Danfoss | 2018.03
VD.GU.A4.02
Data sheet ECA 32 input / output extension module for ECL Comfort 310 / 310B
Wiring example,
relay outputs
Wiring example,
0 - 10 V output
VD.GU.A4.02
© Danfoss | 2018.03 | 3