Danfoss EBI4 LP1P Data sheet

Data sheet

Electronic Ignition Units

EBI4 LP1P

Application

The EBI4 LP1P unit series is specially designed

Applications and Features

for applications where constant duty is required.

1 pole output

 

Low power consumption due to high

EBI4 LP1P is a 1-pole version for ignition

 

efficiency (new technology)

between 1 electrode and frame.

Earth connection through the primary cable

 

-marking in accordance with the direc-

 

 

tives: EMC, LVD, RoHs and EAC.

EBI4 LP1P

 

 

• Application requiring constant duty

 

 

• 1-pole high voltage high frequency output

 

 

• 100% ED at 30°C

 

 

• Front connection for secondary cables

 

 

• 230 Vac or 120 Vac

 

 

© Danfoss | 2021.09

AI360450046706en-010401 | 1

Danfoss EBI4 LP1P Data sheet

 

 

 

 

 

 

 

 

 

 

Data sheet

Electronic Ignition Units EBI4 LP1P

 

 

Technical data

Dimensions and connections

Type EBI4 LP1P

230 V. Code no. 052F4253

120 V. Code no. 052F4270

Mains connection

230 V - 0.25 A - 50/60 Hz - 60 VA

120 V - 0.40 A - 50/60 Hz - 50 VA

 

 

 

Working range

187-255 V

102-132 V

 

 

 

ED % *

100% at 30°C

100% at 30°C

 

 

 

Secondary connection **

12 kV

12 kV

 

 

 

Short circuit current (rms)

30 mA

30 mA

 

 

 

Secondary frequency

25 kHz

22 kHz

 

 

 

Ambient temperature *

-10 to +50°C

-10 to +50°C

 

 

 

Storage temperature

-25 to +85°C

-25 to +85°C

 

 

 

Enclosure

IP 40

IP 40

 

 

 

Primary connection

3 × 0.5 mm2 cable with special

3 × 0.5 mm2 cable with special

 

plug

plug

Secondary connections

1 × Ø4 mm plugs

1 × Ø4 mm plugs

 

 

 

Earthing

Through the primary cable

Through the primary cable

 

 

 

Weight

235 g

235 g

 

 

 

Packing format

40 pcs. Industry

40 pcs. Industry

 

 

 

*Any use above 30°C can potentially shorten the lifetime and reduce the performance of the EBI.

**Avoid use of divergent electrodes due to risk of electrical cable break down and too high ignition voltage.

EBI4 LP1P

b: Right terminal

b+c

c: Earth connection

 

 

 

 

Primary plug

With secondary front connection

Bush secondary

Additional documentation on burner components is available on http://danfoss.com/

2 | © Danfoss | DCS-SGDPT/DK | 2021.09

AI360450046706en-010401

Loading...