Data sheet
Electronic Ignition Units
EBI4 LP1P
Application
The EBI4 LP1P unit series is specially designed
for applications where cons tant duty is required.
EBI4 LP1P is a 1-pole version for ignition
between 1 electrode and frame.
EBI4 LP1P
• Application requiring constant duty
• 1-pole high voltage high frequency output
• 100% ED at 30°C
• Front connection for secondary cables
• 230 Vac or 120 Vac
Applications and Features
• 1 pole output
•
Low power consumption due to high
efficiency (new technology)
• Earth connection through the primary cable
•
-marking in accordance with the direc-
tives: EMC, LVD, RoHs and EAC.
© Danfoss | 2021.09
AI360450046706en-010401 | 1
Data sheet Electronic Ignition Units EBI4 LP1P
Technical data
Dimensions and
connections
Type EBI4 LP1P 230 V. Code no. 052F4253 120 V. Code no. 052F4270
Mains connection 230 V - 0.25 A - 50/60 Hz - 60 VA 120 V - 0.40 A - 50/60 Hz - 50 VA
Working range 187-255 V 102-132 V
ED % * 100% at 30°C 100% at 30°C
Secondary connection ** 12 kV 12 kV
Short circuit current (rms) 30 mA 30 mA
Secondary frequency 25 kHz 22 kHz
Ambient temperature * -10 to +50°C -10 to +50°C
Storage temperature -25 to +85°C -25 to +85°C
Enclosure IP 40 IP 40
Primary connection 3 × 0.5 mm2 cable with special
Secondary connections 1 × Ø4 mm plugs 1 × Ø4 mm plugs
Earthing Through the primary cable Through the primary cable
Weight 235 g 235 g
Packing format 40 pcs. Industry 40 pcs. Industry
* Any use above 30°C can potentially shorten the lifetime and reduce the performance of the EBI.
** Avoid use of divergent electrodes due to risk of electrical cable break down and too high ignition voltage.
EBI4 LP1P
b+c
plug
b: Right terminal
c: Earth connection
3 × 0.5 mm2 cable with special
plug
Primary plug
With secondary front connection
Additional documentation on burner components is available on http://danfoss.com/
Bush secondary
2 | © Danfoss | DCS-SGDPT/DK | 2021.09
AI360450046706en-010401