Danfoss EBI4 LP1P Data sheet

Data sheet
Electronic Ignition Units
EBI4 LP1P
Application
The EBI4 LP1P unit series is specially designed for applications where cons tant duty is required.
EBI4 LP1P is a 1-pole version for ignition between 1 electrode and frame.
EBI4 LP1P
• Application requiring constant duty
• 1-pole high voltage high frequency output
• 100% ED at 30°C
• Front connection for secondary cables
• 230 Vac or 120 Vac
Applications and Features
Low power consumption due to high
efficiency (new technology)
• Earth connection through the primary cable
-marking in accordance with the direc-
tives: EMC, LVD, RoHs and EAC.
© Danfoss | 2021.09
AI360450046706en-010401 | 1
Data sheet Electronic Ignition Units EBI4 LP1P
Technical data
Dimensions and connections
Type EBI4 LP1P 230 V. Code no. 052F4253 120 V. Code no. 052F4270
Mains connection 230 V - 0.25 A - 50/60 Hz - 60 VA 120 V - 0.40 A - 50/60 Hz - 50 VA
Working range 187-255 V 102-132 V
ED % * 100% at 30°C 100% at 30°C
Secondary connection ** 12 kV 12 kV
Short circuit current (rms) 30 mA 30 mA
Secondary frequency 25 kHz 22 kHz
Ambient temperature * -10 to +50°C -10 to +50°C
Storage temperature -25 to +85°C -25 to +85°C
Enclosure IP 40 IP 40
Primary connection 3 × 0.5 mm2 cable with special
Secondary connections 1 × Ø4 mm plugs 1 × Ø4 mm plugs
Earthing Through the primary cable Through the primary cable
Weight 235 g 235 g
Packing format 40 pcs. Industry 40 pcs. Industry
* Any use above 30°C can potentially shorten the lifetime and reduce the performance of the EBI. ** Avoid use of divergent electrodes due to risk of electrical cable break down and too high ignition voltage.
EBI4 LP1P
b+c
plug
b: Right terminal c: Earth connection
3 × 0.5 mm2 cable with special plug
Primary plug
With secondary front connection
Additional documentation on burner components is available on http://danfoss.com/
Bush secondary
2 | © Danfoss | DCS-SGDPT/DK | 2021.09
AI360450046706en-010401