Danfoss EBI4 HP Data sheet

Data sheet
Electronic Ignition Units
EBI4 HP Series
Application
The EBI4 HP unit series is specially designed for applications where High Power ignition is required.
EBI4 HPM is a 2-pole version with secondary midpoint grounded. EBI HP1P is a 1-pole version for ignition between one electrode and frame.
The units are characterized by a very powerful spark, capable of igniting large capacit y oil and gas burners. They may also be used in applications where high ignition performance and reliability are required.
EBI4 HPM
Oil and gas burners requiring high power
ignition
• 33% ED at 60°C
Top or front connection for secondary cables
• 230 V
EBI4 HP1P
Oil and gas burners requiring high power
ignition
• 33% ED at 60°C
Top or front connection for secondary cables
• 230 V
Applications and Features
• 1- or 2-pole ignition
Low power consumption due to high
efficiency (new technology)
Earth connection through the primary cable
• Same dimensions and flexible mounting as the well-known EBI series
-
marking in accordance with the direc-
tives: EMC, LVD, RoHs
© Danfoss | 2019.08
VD.AY.Q2.02 | 1
Data sheet Electronic Ignition Units EBI4 HP Series
Technical data
Dimensions and connections
Type EBI4 HPM EBI4 HP1P
Mains connection 230 V - 0.4 A - 50/60 Hz - 90 VA
Working range 187-255 V
Main fuse 10 A
Secondary connection* Short circuit current (rms) Frequency
ED % in 3 min. 33% at 60°C
Ambient temperature -10 to +60°C
Storage temperature -25 to +85°C
Enclosure IP 40
Primary connection 3 × 0.5 mm2 cable with special plug
Secondary connections 2 × Ø4 mm plugs 1 × Ø4 mm plugs
Earthing Through the primary cable
Distance between electrodes Recommended 2.5 mm to 5 mm
Weight 300 g
* Avoid use of divergent electrodes due to risk of electrical cable break down and too high ignition voltage.
EBI4 HPM EBI4 HP1P a: Left terminal
a+b+c b+c
2 × 7.5 kV
48 mA 18 kHz
3 × 0.75 mm2 cable with standard AMP connection
b: Right terminal c: Earth connection
12 kV 48 mA 18 kHz
Primary plug
With secondary front connection
With secondary top connection
Additional documentation on burner components is available on http://heating.danfoss.com/
Bush, secondary
Primary plug
Bush, secondary
2 | © Danfoss | DHS-SDDT/DK | 2019.08
VD.AY.Q2.02
Loading...