Danfoss EBI4 C Data sheet

Data sheet

Electronic Ignition Units

EBI4 C Series

Application

The EBI4 C unit series is specially designed for applications where constant ignition is required.

EBI4 CM is a 2-pole version with secondary midpoint grounded. EBI4 C1P is a 1-pole version for ignition between 1 electrode and frame.

EBI4 CM

Oil/gas burners requiring constant ignition

2-pole ignition

Secondary mid-point connected to earth/ frame

100% ED at 35°C/70% ED at 60°C

Top or front connection for secondary cables

230 V

EBI4 C1P

Gas burners a.o. application requiring constant ignition

1-pole ignition between 1 electrode and frame

100% ED at 35°C/70% ED at 60°C

Top or front connection for secondary cables

230 V

Applications and Features

1- or 2-pole ignition

Low power consumption due to high efficiency (new technology)

Earth connection through the primary cable

Same dimensions and flexible mounting as the well-known EBI series

-marking in accordance with the directives: EMC, LVD, RoHs

© Danfoss | 2019.08

VD.AY.M2.02 | 1

Danfoss EBI4 C Data sheet

 

 

 

 

 

 

 

 

 

 

Data sheet

Electronic Ignition Units EBI4 C Series

 

 

Technical data

Dimensions and connections

Type

EBI4 CM

 

EBI4 C1P

 

 

 

Mains connection

230 V - 0.25 A - 50/60 Hz - 60 VA

 

 

 

Working range

 

187-255 V

 

 

 

Main fuse

 

10 A

 

 

ED % in 3 min.

100% at 35°C/70% at 60°C

 

 

 

 

Secondary connection*

2 × 7.5 kV

 

12 kV

Short circuit current (rms)

30 mA (rms)

 

30 mA (rms)

Frequency

25 kHz

 

25 kHz

 

 

 

 

Ambient temperature

 

-10 to +60°C

 

 

 

Storage temperature

 

-25 to +85°C

 

 

 

Enclosure

 

IP 40

 

 

Primary connection

3 × 0.5 mm2 cable with special plug

 

3 × 0.75 mm2 cable with standard AMP connection

Secondary connections

2 × Ø4 mm plugs

 

1 × Ø4 mm plugs

 

 

 

Earthing

Through the primary cable

 

 

Distance between electrodes

Recommended 2.5 mm to 5 mm

 

 

 

Weight

 

300 g

 

 

 

 

* Avoid use of divergent electrodes due to risk of electrical cable break down and too high ignition voltage.

EBI4 CM EBI4 C1P

EBI4 CM EBI4 C1P

a: Left terminal

 

 

b: Right terminal

a+b+c

b+c

c: Earth connection

 

 

 

 

Primary plug

With secondary front connection

Bush secondary

 

Primary plug

With secondary top connection

Bush secondary

Additional documentation on burner components is available on http://heating.danfoss.com/

2 | © Danfoss | DHS-SDDT/DK | 2019.08

VD.AY.M2.02

Loading...