Danfoss DV15-P5-24-FD Technical Information

Directional Control Valves Technical Information
4 Way, 2 Position Hydraulic Piloted DV15-P5-24-FD
OPERATION
APPLICATIONS
This valve is primarily used for reversing fan drive circuits where the open-transition design is important for smooth shifting and minimal pressure spikes during reversing. The valve can be piloted with many 2-way valves including solenoid, sequence, relief or manual valves with the internal pilot drain orice option. Alternatively, it can also be piloted with a 2-position, 3-way solenoid valve using the internal pilot drain plug option.
SPECIFICATIONS
Rated Pressure* 230 bar [3335 psi]
Rated Flow at 7 bar
[100 psi]
Maximum Rated Flow 80 l/min
Minimum pilot pressure 2 bar [29 psi]
Weight 0.44 kg [0.95 lbs]
Cavity NCS12/5
* Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles).
70 l/min [18.4 US gal/min]
[21.1 US gal/min]
PERFORMANCE CURVE
SCHEMATICS
DV - 39BC332375730110en-000101 • February 2020
DIMENSIONS
mm [in]
Directional Control Valves Technical Information
4 Way, 2 Position Hydraulic Piloted DV15-P5-24-FD
EXAMPLE CIRCUITS
Piloted with 2-way valve and internal pilot drain orice option
DV15-P5-24-FD
SVP08-NC
Reversing Fan Drive Circuits
ORDERING INFORMATION
Piloted with 3-way valve and internal pilot drain plug option
DV15-P5-24-FD
SV08-23-01
Loading...