Data Sheet
DEVIwet™ 230V room thermostats
for hydronic floor heating
Description
DEVIwet™ Dial DEVIwet™ Display/Programmable
DEVIwet™ is a range of room thermostats for
hydronic floor heating applications.
The thermostats are mains powered and can be
used as a stand-alone thermostats or in combination with wiring center 088H0016.
DEVIwet™ can control up to five thermal actuators
and comes in three versions:
• DEVIwet™ Dial: uses a relay output. The room
temperature is set with the dial in a range from
5 to 30 °C. The dial can be removed, allowing
limitation pins to be used to limit the setpoint
range.
• DEVIwet™ Display: uses a triac output. The
room temperature is set in a range from 5 to
35 °C via a “touch on glass” interface with a shine
through display. The display is “OFF” in normal
operation.
Features Dial Display Programmable
Neutral design and simple user interface x x x
Compatible with 3rd party wall frames x x x
Very high UV-resistance x x x
Can be used with 230 V NC or NO actuators x x x
Frost protection setting x x x
ON/OFF control x
Range limitation via pins x
Accurate PWM-control x x
Shine through display x x
Range limitation via user menu x x
Valve exercise feature x x
Can be optimized for different heatsources x x
Seven pre-defined schedules and forecast x
Can be used in systems with cooling x
Can be used with floor sensor (optional) x
• DEVIwet™ Programmable: uses a triac output.
The room temperature is set in a range from 5
to 35 °C via a “touch on glass” interface with a
shine through display. The display is “OFF” in
normal operation. The user can choose between
7 pre-defined heating schedules. A schedule
can be temporarily overrided by using the three
mode keys. The thermostat can also operate
without scheduling (constant room temperature
setpoint). The thermostat uses forecast (adaptive learning).
VDMBA202
© Danfoss | FHH | 2017.03 | 1
Data Sheet DEVIwet™ 230V room thermostats for hydronic floor heating
Ordering
Accessories
Technical specifications
Product Size For junction box Code no.
DEVIwet™ Dial 80 x 80 mm Euro, Ø68 mm 088U2000
DEVIwet™ Display 80 x 80 mm Euro, Ø68 mm 088U2001
DEVIwet™ Programmable 80 x 80 mm Euro, Ø68 mm 088U2002
Product Description Code no.
Danfoss FH-WC, 230V Wiring center, 8 channels, up to 16 outputs 088H0016
DEVIwet™ Floor Sensor 47 kΩ, 3 m, IP 67 0 88 U1110
Dial Display Programmable
User interface Dial Capacitive touch and shine through display
Heating icon, arrow
User interface features -
Display type -
Display features - Switches OFF after 10 sec. with no interaction
Automatic daylight saving time - -
Heating schedules - - 7 pre-defined
Change over, cooling - - Yes, via 230 V terminal
Global setback/Away - - Yes, via 230 V terminal
Temperature setting range 5 - 30 °C 5 - 35 °C
Frost protection setting 5 °C
Ambient temp., storage -20 to 60 °C
Ambient temp., in application 0 to + 40 °C
Controller, type On/Off Adjustable Pulse Width Modulation
Max. continuous load (output) < 50 mA /10 W (= 5 pcs. Danfoss TWA actuators)
Max. inrush current (actuator) 3 A ≤ 100 ms
Power consumption 0.4 W 0.2 W
Power supply (excl. actuators) 220-240 V, 50/60 Hz
Sensor, room 47 kΩ, NTC
Sensor, floor (optional) - - NTC 47 kΩ, 3 m, IP 68
Shell material White parts: PC ASA. Grey parts: PC, 10% glass
IP class 21
Protection class Class II
up/down, confirm
key, back key
Hybrid: red single LED’s and custom
Heating icon, arrow
up/down, confirm
key, back key, Home,
Away, Night, Settings
segment
Standard
(can be turned off)
2 | © Danfoss | FHH | 2017.03
ErP class
Approval CE, RohS, WEEE
Colour White RAL9010 / Dark Grey RAL7024
Dimensions 80 x 80 x 11 mm
(1%) (2%)
VDMBA202
Data Sheet DEVIwet™ 230V room thermostats for hydronic floor heating
Application examples,
DEVIwet™ Dial
Wiring without wiring center, neutral wire from main installation
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Dial 230V IW
Max. load: 10W/50mA 088N3485 V00
LoadNCLoad
N N L
NO
Min. 3G1.5 cable to thermostat
(not counting Protective earth)
M
Max. 5 actuators, type NC or NO, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
L
50-60 Hz
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Dial 230V IW
Max. load: 10W/50mA 088N3485 V00
LoadNCLoad
N N L
NO
L
50-60 Hz
Wiring with wiring center
Danfoss A/S
6430 Nordborg
Denmark
DEVIwet™ Dial 230V IW
Max. load: 10W/50mA 088N3485 V00
LoadNCLoad
N N L
NO
IP21
T30
Min. 4G1.5 cable to thermostat
(not counting Protective earth)
M
Max. 5 actuators, type NC or NO, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
N
N
L
LOAD
L
FH-WC
M
088H0016
1)
M
VDMBA202
Min. 3G1.5 cable to thermostat
(not counting Protective Earth)
1)
Note! Wiring center FH-WC 088H0016 only supports NC actuators.
Max. 5 actuators, type NC, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
© Danfoss | FHH | 2017.03 | 3
Data Sheet DEVIwet™ 230V room thermostats for hydronic floor heating
Application examples,
DEVIwet™ Display
Wiring without wiring center, neutral wire from main installation
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Display 230V IW
Max. load: 10W/50mA 088N3488 V00
Load
N LN
L
Min. 3G1.5 cable to thermostat
(not counting Protective earth)
M
Max. 5 actuators, type NC or NO, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
L
50-60 Hz
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Display 230V IW
Max. load: 10W/50mA 088N3488 V00
Load
N LN
L
L
50-60 Hz
Wiring with wiring center
Danfoss A/S
6430 Nordborg
Denmark
DEVIwet™ Display 230V IW
Max. load: 10W/50mA 088N3488 V00
Load
N LN
L
IP21
T30
Min. 4G1.5 cable to thermostat
(not counting Protective earth)
M
Max. 5 actuators, type NC or NO, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
N
N
L
LOAD
L
FH-WC
M
088H0016
1)
M
4 | © Danfoss | FHH | 2017.03
Min. 3G1.5 cable to thermostat
(not counting Protective Earth)
1)
Note! Wiring center FH-WC 088H0016 only supports NC actuators.
Max. 5 actuators, type NC, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
VDMBA202
Data Sheet DEVIwet™ 230V room thermostats for hydronic floor heating
Application examples,
DEVIwet™ Programmable
Wiring without wiring center, neutral wire from main installation
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Programmable 230V IW
Max. load: 10W/50mA 088N3491 V00
LN
Load
L
TC
Min. 3G1.5 cable to thermostat
(not counting Protective earth)
M
Max. 5 actuators, type NC or NO, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
L
50-60 Hz
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Programmable 230V IW
Max. load: 10W/50mA 088N3491 V00
LN
Load
L
TC
L
50-60 Hz
Wiring with wiring center
Danfoss A/S
6430 Nordborg
Denmark
DEVIwet™ Programmable 230V IW
Max. load: 10W/50mA 088N3491 V00
LNNN TC
Load
L
IP21
T30
Min. 4G1.5 cable to thermostat
(not counting Protective earth)
M
Max. 5 actuators, type NC or NO, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
N
N
L
LOAD
L
FH-WC
M
088H0016
1)
M
VDMBA202
Min. 3G1.5 cable to thermostat
(not counting Protective Earth)
1)
Note! Wiring center FH-WC 088H0016 only supports NC actuators, and does not support cooling change-over or global
setback.
Max. 5 actuators, type NC, 230V
Max. 10 W / Max. 50 mA continuous load
Max. 3 A inrush current ≤ 100 ms
© Danfoss | FHH | 2017.03 | 5
Data Sheet DEVIwet™ 230V room thermostats for hydronic floor heating
Application examples,
DEVIwet™ Programmable
How to set thermostats to cooling mode from external device
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Programmable 230V IW
Max. load: 10W/50mA 088N3491 V00
LNNN TC
Load
L
M
S
L
50-60 Hz
How to set thermostats to Away (global standby) from external device
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Programmable 230V IW
Max. load: 10W/50mA 088N3491 V00
LNNN TC
Load
L
M
S
L
50-60 Hz
S : Can be mechanical switch Sum-
mer / Winter or relay activated
by external device.
Use the same phase which
supplies the thermostat.
The thermostat/room remains
in cooling mode as long as
the phase is live onto the
terminal.
Note! Switch not in delivery.
S : Can be mechanical switch Home
/ Away or relay activated by
external device.
Use the same phase which
supplies the thermostat.
The thermostat/room remains in
Away mode as long as the phase
is live onto the
terminal.
Note! Switch not in delivery.
6 | © Danfoss | FHH | 2017.03
How to install a floor sensor
Danfoss A/S
6430 Nordborg
Denmark
IP21
T30
DEVIwet™ Programmable 230V IW
Max. load: 10W/50mA 088N3491 V00
LNNN TC
Load
L
M
L
50-60 Hz
Note!
Use DEVIwet™ 47 KΩ NTC floor sensor, code no.: 088U1110.
Always route external sensors in a suitable electrical pipe!
1. R > 5 cm.
2. Anchor electrical pipe firmly before laying concrete.
3. Concrete.
4. End of pipe must be closed / sealed.
1. 2. 3. 4.
VDMBA202
Data Sheet DEVIwet™ 230V room thermostats for hydronic floor heating
Dimensions
71
51
47
11
DEVIwet™ Dial 088U2000
71
47
23
71
71
80
80
80
51
23
11
DEVIwet™ Display 088U2001 & Programmable 088U2002
80
VDMBA202
© Danfoss | FHH | 2017.03 | 7
Danfoss A/S
Floor Heating Hydronics • Ulvehavevej 61 • DK-7100 Vejle • Denmark • Phone: +45 7488 8500 • Fax: +45 7488 8501
heating@danfoss.com • www.floorheating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.