Danfoss DEVIreg Opti Installation guide

Installation Guide

DEVIreg™ Opti

Electronic Timer Thermostat fulfilling

Eco Design Directive

www.DEVI.com

DEVIreg™ Opti

Table of Contents

1. Introduction   2

2. Technical Specifications   3

3. Safety Instructions   5

4. Mounting Instructions   7

5. Display Symbols   11

6. Configuring   15

7. Settings & Break out   22

8. Disposal Instruction   24

9. Warranty   25

1 Introduction

DEVIreg™ Opti is an electronic programmable timer thermostat used for controlling electrical floor heating elements. The thermostat is designed for fixed installation only and can be used for both direct heating of the entire room and for comfort heating of the floor. Among others, the thermostat has the following features:

2

Installation Guide

DEVIreg™ Opti

A screen display operated by buttons.

An easy-to-follow, menu driven programming and operation.

Pre-installed timer settings.

Offered with integrated frame.

Using DEVI standard NTC floor sensor (15 k Ohm at 25°C).

Open window detection.

Low stand-by energy consumption.

Weekly timer.

More information about this product can be found at: devi.com

2

Technical Specifications

 

 

Operation voltage

220-240 V~, 50Hz

Standby power consumption

Max. 0,5 W

Relay:

 

 

Resistive load

Max. 13 A / 2990 W @ 230 V

Inductive load

Max. 1 A cos = 0,3

 

 

 

Installation Guide

3

 

 

 

DEVIreg™ Opti

 

 

 

 

 

 

Sensing units (floor sensor)

NTC 15 kOhm at 25°C (Default)

Sensing values:

 

0°C

42 kOhm

20°C

18 kOhm

50°C

6 kOhm

 

 

Control

PWM (Pulse Width Modulation)

Cable specification max.

1x4 mm2 and 2x2,5 mm2

Ambient temperature

0° to +35°C

Frost protection temperature

5°C to +9°C (default 5°C)

 

 

Temperature range

Room temperature: 5-35°C.

 

 

 

Floor temperature: 5-45°C.

 

 

 

Max. floor: 20-35°C (if unrecover-

 

 

 

able seal is broken then up to 45°C).

 

 

 

Min. floor: 10-34,5°C, only with

 

 

 

combination of room and floor

 

 

 

sensor.

Sensor failure monitoring

The thermostat has a built-in

 

 

 

monitoring circuit, which

 

 

 

will switch off the heating if

 

 

 

the floor sensor is disconnected

 

 

 

or short-circuited

 

 

Ball pressure test temperature

75°C

Pollution degree

2 (domestic use)

 

 

 

 

 

 

 

 

4

 

 

Installation Guide

DEVIreg™ Opti

Controller type

1B

Software class

A

 

 

Storage temperature

-25°C to +60°C

IP class

21

 

 

Protection class

Class II -

 

 

Dimensions

85 x 85 x 44 mm

 

(in-wall depth: 24 mm)

Weight

138 g

Electrical safety and Electro-Magnetic Compatibility for this product is covered by the compliance with the EN/IEC Standard “Automatic electrical controls for household and similar use”:

EN/IEC 60730-1 (general)

EN/IEC 60730-2-9 (thermostat)

3 Safety Instructions

Important: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.

Installation Guide

5

DEVIreg™ Opti

Make sure the mains supply to the thermostat is turned off before installation.

Please also note the following:

The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.

The thermostat must be connected to a power supply via an all-pole disconnection switch.

Always connect the thermostat to continuous power supply.

Do not expose the thermostat to moisture, water, dust, and excessive heat.

This thermostat can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a

6

Installation Guide

DEVIreg™ Opti

safe way and understand the hazards involved, by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the thermostat.

Cleaning and user maintenance shall not be made by children without supervision.

4 Mounting Instructions

Please observe the following placement guidelines:

Place the thermostat at a suitable height on the wall (typically 80-170 cm.).

The thermostat should not be placed in wet rooms. Thermostat must be placed outside zone 2. Place it in an adjacent room and use floor sensor only. Always place the thermostat according to local regulation on IP classes.

Do not place the thermostat on the inner side of a poorly insulated exterior wall.

Installation Guide

7

Danfoss DEVIreg Opti Installation guide

DEVIreg™ Opti

Always install the thermostat at least 50 cm from windows and doors, due to draft, when using regulation in: floor and room mode or room alone mode.

Do not place the thermostat in a way that it will be exposed to direct sunlight.

Note: A floor sensor is recommended in all floor heating applications and mandatory to thin matsand under wooden floors to reduce the risk of overheating the floor.

• Place the floor sensor

 

 

in a protecting plastic

1

2

conduit in the floor

 

 

construction in an ap-

 

 

propriate place, where

 

 

the floor is not exposed

 

to sunlight or draft

 

 

from door openings.

 

 

Equally distant and >2 cm from the heating cables on both sides.

8

Installation Guide

DEVIreg™ Opti

The conduit should be flush with the floor surface, countersink the conduit if necessary and possible.

Route the conduit to the connection box.

The bending radius of the conduit must be min 50 mm.

Follow the steps below to mount the thermostat:

1.Unpack thermostat

2.Remove the front cover as showed on Pic. 1.

3.Connect the thermostat according to the connection diagram.

The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.

 

 

 

 

 

 

 

 

Pic. 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S2

S1

 

L

L

N

 

N

 

 

LOAD

LOAD

 

 

 

 

 

 

Max Load

Mains 220-240V~

Sensor

 

13(1) A

 

 

 

50Hz

Made in P.R.C. Danfoss A/S, 6430 Nordborg, Denmark

IP21

0T35

Ambient Temperature: 0-35°C

Standby maximum 0.5W

DEVIreg™ Opti

Pic. 2

Note: Always install the floor sensor in a conduit in the floor.

Installation Guide