Danfoss DEVIreg Opti Installation guide

Installation Guide
DEVIreg™ Opti
Electronic Timer Thermostat fulfilling
Eco Design Directive
www.DEVI.com
DEVIreg™ Opti
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5. Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6. Configuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Settings & Break out . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8. Disposal Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1 Introduction
Installation Guide2
DEVIreg™ Opti
A screen display operated by buttons.
An easy-to-follow, menu driven programming and operation.
Pre-installed timer settings.
Offered with integrated frame.
Using DEVI standard NTC floor sensor (15 k Ohm at 25°C).
Open window detection.
Low stand-by energy consumption.
Weekly timer.
More information about this product can be found at: devi.com
2 Technical Specifications
Operation voltage 220-240 V~, 50Hz
Standby power consumption Max. 0,5 W
Relay: Resistive load Inductive load
Max. 13 A / 2990 W @ 230 V Max. 1 A cos = 0,3
3Installation Guide
DEVIreg™ Opti
Sensing units (floor sensor) NTC 15 kOhm at 25°C (Default)
Sensing values: 0°C 20°C 50°C
Control PWM (Pulse Width Modulation)
Cable specification max. 1x4 mm2 and 2x2,5 mm
Ambient temperature 0° to +35°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Sensor failure monitoring The thermostat has a built-in
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
42 kOhm 18 kOhm 6 kOhm
2
Floor temperature: 5-45°C. Max. floor: 20-35°C (if unrecover­able seal is broken then up to 45°C). Min. floor: 10-34,5°C, only with combination of room and floor sensor.
monitoring circuit, which will switch off the heating if the floor sensor is disconnected or short-circuited
Installation Guide4
DEVIreg™ Opti
Controller type 1B
Software class A
Storage temperature -25°C to +60°C
IP class 21
Protection class
Dimensions 85 x 85 x 44 mm
Weight 138 g
Class II -
(in-wall depth: 24 mm)
Electrical safety and Electro-Magnetic Compatibility for this product is covered by the compliance with the EN/IEC Standard “Automatic electrical controls for household and similar use”:
EN/IEC 60730-1 (general)
EN/IEC 60730-2-9 (thermostat)
3 Safety Instructions
Important: When the thermostat is used to control a
floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.
5Installation Guide
DEVIreg™ Opti
Make sure the mains supply to the thermostat is turned off before installation.
Please also note the following:
The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.
The thermostat must be connected to a power supply via an all-pole disconnection switch.
Always connect the thermostat to continuous power supply.
Do not expose the thermostat to moisture, water, dust, and excessive heat.
This thermostat can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a
Installation Guide6
DEVIreg™ Opti
safe way and understand the hazards involved, by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the thermostat.
Cleaning and user maintenance shall not be made by children without supervision.
4 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the wall (typically 80-170 cm.).
The thermostat should not be placed in wet rooms. Thermostat must be placed outside zone
2. Place it in an adjacent room and use floor sen­sor only. Always place the thermostat according to local regulation on IP classes.
Do not place the thermostat on the inner side of a poorly insulated exterior wall.
7Installation Guide
DEVIreg™ Opti
12
Always install the thermostat at least 50 cm from windows and doors, due to draft, when using regulation in: floor and room mode or room alone mode.
Do not place the thermostat in a way that it will be exposed to direct sunlight.
Note: A floor sensor is recommended in all floor heating applications and mandatory to thin matsand under wooden floors to reduce the risk of overheating the floor.
• Place the floor sensor
in a protecting plastic conduit in the floor construction in an ap­propriate place, where the floor is not exposed to sunlight or draft from door openings.
• Equally distant and >2 cm from the heating cables on
both sides.
Installation Guide8
DEVIreg™ Opti
• The conduit should be flush with the floor surface, coun-
tersink the conduit if necessary and possible.
• Route the conduit to the connection box.
• The bending radius of the conduit must be min 50 mm.
Follow the steps below to mount the thermostat:
1. Unpack thermostat
2. Remove the front cover as showed
on Pic. 1.
3. Connect the thermostat accor-
ding to the connection diagram.
The screen of the heating cable must be connected to the earth
Made in P.R.C.
conductor of the power supply cable by using a separate con­nector.
Note: Always install the floor sensor in a conduit in the floor.
S2 S1 L
Max Load
13(1) ASensor
Danfoss A/S, 6430 Nordborg, Denmark
IP21
0T35
Ambient Temperature: 0-35°C Standby maximum 0.5W
DEVIreg™ Opti
Pic. 2
Pic. 1
N
N
LOADLLOAD
Mains 220-240V~
50Hz
9Installation Guide
DEVIreg™ Opti
4. Fasten the thermostats back part
firmly to a flush mounted wall box or an exterior wall box by driving the screws through the holes in each side of the thermostat.
5. Click the front part module in
place. Pay attention, in relation to the female header, in not to bend­ing the connectors. Press carefully until the frame is fixed firmly.
When mounting and reassembling the thermostat.
Pic. 3
Pic. 4
Important: Do NOT press in the center of the display
screen.
Battery:
The current time and day is kept for min. 60 days if mains supply is off. All other settings are stored permanently.
Installation Guide10
DEVIreg™ Opti
5 Display Symbols
Top part main functionalities are to support user interface through display and hold all the controller logic.
Display main functionalities are to show the current status of the Thermostat and recognize the user actions from the buttons. Display consists of different buttons, numbers and symbols.
Nr. Type Description
ON/OFF button
Arrow Up / Down button
1
2
3 Mode button
4 Timer button
11Installation Guide
DEVIreg™ Opti
Symbol indications
Symbol Description Symbol Description
Week Day Heating is ON
Time Display,
24 Hour
Floor
Temperature
Room
Temperature
Away Mode
Timer Mode
Manual Mode Alarm/Error
Frost Protec-
tion Mode
Periode Symbol
at timer mode
Safety Lock
Open Window
Current Tem-
Comfort Tem-
Temperature
The shorter line
indicates the
current period.
Installation Guide12
indication
perature
perature
Economy
DEVIreg™ Opti
Interaction directly on thermostat
Function Button Description
Turn thermo-
stat on / off
Setting of
different
modes
Adjust
temperature
Activate button:
Hold for 2 sec.
Activate button:
Up: activation button
Down: activation
button
Thermostat switch on and display current temperature and other settings
Display cycles through following modes: Timer / Manual / Away / Frost protection
Increases active mode/ temporary set point
Decreases active mode/ temporary set point
Floor tem-
perature
Activate simultane-
ously buttons
Hold 8 sec.: Display shows current floor temperature. Floor temp. icon appears. From timer, manual, frost mode
13Installation Guide
DEVIreg™ Opti
Safety lock
Factory
restore
Setting timer
mode
Activate simultane-
ously buttons
Activate simultane-
ously buttons
Activate button
To Activate/Deactivate safety lock, hold for 8 sec. Safety lock icon appears.
Turn thermostat OFF, hold for 10 sec. 5 sec. count down appears.
Display cycles through timer setting modes. Activates in all modes.
To save energy, when no interaction from user for >20 sec., thermostat will go into a stand by mode, where currently measured temperature is displayed continuously. Interaction from user, by pushing any of the buttons, will reactivate the display (On/Off button, push and hold for 2 sec.).
Error codes
When the error occurs, the heating is turned off. When error is resolved the thermostat, in some cases, will require a restart to start heating again.
Installation Guide14
DEVIreg™ Opti
Error type N r. Description Solution
Floor Sensor
short circuited
Floor Sensor
disconnect
Room or Floor
Sensor short
circuited
Room or Floor
Sensor
disconnect
Battery
missing
Floor sensor is measuring
E1
E2
E3
E4
very high temperature
Floor sensor is measuring
very low temperature
Sensor is measuring too
high temperature (>50°C).
Sensor is measuring too low temperature (<0°C).
Battery is missing or needs
values.
values.
a replacement
Contact service
Is floor sensor
connected?
Contact service
Turn Off. Cool down. If persist, contact service.
Turn Off and
On. If persist,
contact service.
Contact
service
6 Configuring - Start up
Setting time
When the thermostat is connected first time, it will open a start up wizard (for further description see following pages).
15Installation Guide
DEVIreg™ Opti
When unit is On (any of the modes) press Timer button (once), "hh:mm" will start to blink.
Adjust the "hh" value with Up & Down buttons, than when reached the desired value press
Timer button to move to "mm" (minutes).
Set the "mm" value with Up & Down buttons, than when reached the desired value press Timer button to move to Weekday.
Adjust the Weekday with Up & Down buttons.
Press the Timer button again, to confirm.
Timer programming
The thermostat comes with 3 preset programs (P1, P2 and P3). Default is set to program P3. Programs can be changed with Up and Down arrows (P3->P2->P1).
The values in the programs (time and temperature) can be adjusted, see the following page. For preset program settings, see the following table:
Installation Guide16
DEVIreg™ Opti
Programs
Days
Day
06:00-
08:00
08:00-
16:00
16:00-
22:30
22:30-
06:00
Morning
Evening
Night
Comfort default temperature 21°C 27°C
Economy default temperature 17°C 20°C
P1
Working
day
MON to
SUN
Comfort Comfort Comfort Comfort
Economy Comfort Economy Comfort
Comfort Comfort Comfort Comfort
Economy Economy Economy Economy
P2
Days at
home
MON to
SUN
Room & Floor Floor only
Mon-Fri: P1
Sat - Sun: P2
MON to
FRI
P3
SAT to
SUN
Adjusting timer programming:
When in timer mode, to adjust current program, press and
hold timer button for 2 sec. When timer program name
(i.e. P3) appears, press timer button again, to change the
17Installation Guide
DEVIreg™ Opti
settings of this program. First, hour and minute settings for all periods (for preset values see table on previous page), than temperatures for comfort and economy periods can
be adjusted, with help of up and down buttons.
Push timer button , for going to next value/period. When programming is finished, operating screen will appear.
Period indicator:
P3:
- Comfort
- Economy
P2:
- Comfort
- Economy
Installation Guide18
DEVIreg™ Opti
The shorter line indicates, the current period (comfort or economy), corresponding to the time setting of the watch.
Note:
The floor and room takes time to heat up. Start comfort heating period before the time, you need them warm.
Away mode:
Is set by pushing mode button , until
away icon appears. Push the timer
button , for 2 sec., to choose the number of away days (between 0-99 days), with up
/ down buttons . Start is at "0" days and it can be
increased by pushing the Up arrow button.
Push timer button again to adjust the away temperature,
can be set between 5-20°C, with up or down arrows. The last set value is used. No confirmation needed. Mode will end if user is pushing any button (Off button, turns the unit
off). Away icon will disappear from screen.
19Installation Guide
DEVIreg™ Opti
Frost protection:
Is set by pushing until frost protection icon appears.
Desired temperature for frost protection can be set in installer menu. Value is between 5-9°C.
If the current room temperature is below the set frost protec-
tion temperature, the heating ON icon will appear, and the thermostat will start heating.
Installer menu:
Settings described in next point (Start up wizard) will be available, uppon accessing this menu.
It's strongly advised: ONLY for the trained installer, to access this menu, as changes of settings can lead into damage of a floor surface.
It can be accessed from OFF state (thermostat is turned off),
by holding the timer button for 10 sec.
The mode button is used for cycling through the
parameters (starting at 1), up & down buttons, for
Installation Guide20
DEVIreg™ Opti
setting the desired value. Push and hold button, for 2 sec., to exit this menu at any time, into a manual operation mode.
Start up wizard:
When first time connecting the thermostat to power, or by accessing installer menu, following parameters can be adjusted:
No. Parameter settings Settings range Default
P01 Set time (Set Hour) 0 - 24 00:
P02 Set time (Set Minute) 0 - 60 :00
P03 Set weekday Monday to Sunday MON
P04 Temperature control mode
P05 Max. floor temperature
P06 Window open function 0: Disable; 1: Enable; 1
P07 Frost protection funciton 0: Disable; 1: Enable; 1
P08 Set frost protection temp. 5-9° C 5
P09 Set minimum floor temperature 0: Disable; 1: Enable; 0
P10 Minimum floor temperature 18-29° C 23
P11 Startup wizard 0: Disable; 1: Enable; 0
01: Room and floor temp. 02: Only floor temp. 03: Only room temp*
20-35° C
(only for 01 & 02 in P04)
2
33
21Installation Guide
DEVIreg™ Opti
1. Insert
P09 and P10 are only accessible if Room and Floor is chosen in P04 (temperature control mode).
* Only room temperate, possible only after break-out (see next page). ** Max. temperature is 0,5°C below value set in P05.
7 Settings & Break out
Room sensor or floor temperature higher than max. 35°C
A “room only” option is also available, but requires that you have to break the small plastic seal on the the back of the display module, e.g. using a
2. Twist
Installation Guide22
DEVIreg™ Opti
screw driver (insert all the way in and twist). It will be possi­ble to set the maximum floor temperature up to 45°. Further­more, it will be possible to use only a room sensor. However, this option is not recommendable due to an increased risk of overheating the floor.
Note: Please contact the floor supplier before changing the maximum floor temperature and be aware of the following:
The floor temperature is measured there, where the sensor is placed.
The temperature of the bottom of a wooden floor can be up to 10˚C higher than the top.
Floor manufactures often specify the max. tempera­ture on the top surface of the floor.
23Installation Guide
DEVIreg™ Opti
Thermal
resist-
ance
Examples of
flooring
[m2K/ W]
0,05
0,10
0,13
8 mm HDF based
laminate
14 mm beech
parquet
22 mm solid oak
plank
Max. carpet thick-
< 0,17
ness suitable for
floor heating
0,18
22 mm solid fir
planks
8 Disposal Instruction
Details
kg/m
3
setting for
25°C floor
temperature
> 800 28°C
650 – 800 31°C
> 800 32°C
Approximate
acc. to EN
1307
34°C
450 – 650 35°C
Installation Guide24
DEVIreg™ Opti
9 Warranty
YEAR
WARR AN TY
The products will, in the event of a fault that can be tracked back to a manufacturing defect in the DEVI product, be re­paired or replaced free of charge. To apply for this warranty the installation must be performed by an authorized installer and the warranty certificate has to be stamped, signed and provid­ed. For more details read our warranty terms and conditions.
25Installation Guide
DEVIreg™ Opti
Installation Guide26
DEVIreg™ Opti
27Installation Guide
DEVIreg™ Opti
Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: EH@DEVI.com www.DEVI.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed. All trade­marks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Produced by Danfoss © 06/201908096400 & VIJWM102