Danfoss DEVIreg Opti Installation guide

Installation Guide
DEVIreg™ Opti
Electronic Timer Thermostat fulfilling
Eco Design Directive
www.DEVI.com
DEVIreg™ Opti
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5. Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6. Configuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Settings & Break out . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8. Disposal Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1 Introduction
Installation Guide2
DEVIreg™ Opti
A screen display operated by buttons.
An easy-to-follow, menu driven programming and operation.
Pre-installed timer settings.
Offered with integrated frame.
Using DEVI standard NTC floor sensor (15 k Ohm at 25°C).
Open window detection.
Low stand-by energy consumption.
Weekly timer.
More information about this product can be found at: devi.com
2 Technical Specifications
Operation voltage 220-240 V~, 50Hz
Standby power consumption Max. 0,5 W
Relay: Resistive load Inductive load
Max. 13 A / 2990 W @ 230 V Max. 1 A cos = 0,3
3Installation Guide
DEVIreg™ Opti
Sensing units (floor sensor) NTC 15 kOhm at 25°C (Default)
Sensing values: 0°C 20°C 50°C
Control PWM (Pulse Width Modulation)
Cable specification max. 1x4 mm2 and 2x2,5 mm
Ambient temperature 0° to +35°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Sensor failure monitoring The thermostat has a built-in
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
42 kOhm 18 kOhm 6 kOhm
2
Floor temperature: 5-45°C. Max. floor: 20-35°C (if unrecover­able seal is broken then up to 45°C). Min. floor: 10-34,5°C, only with combination of room and floor sensor.
monitoring circuit, which will switch off the heating if the floor sensor is disconnected or short-circuited
Installation Guide4
DEVIreg™ Opti
Controller type 1B
Software class A
Storage temperature -25°C to +60°C
IP class 21
Protection class
Dimensions 85 x 85 x 44 mm
Weight 138 g
Class II -
(in-wall depth: 24 mm)
Electrical safety and Electro-Magnetic Compatibility for this product is covered by the compliance with the EN/IEC Standard “Automatic electrical controls for household and similar use”:
EN/IEC 60730-1 (general)
EN/IEC 60730-2-9 (thermostat)
3 Safety Instructions
Important: When the thermostat is used to control a
floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.
5Installation Guide
DEVIreg™ Opti
Make sure the mains supply to the thermostat is turned off before installation.
Please also note the following:
The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.
The thermostat must be connected to a power supply via an all-pole disconnection switch.
Always connect the thermostat to continuous power supply.
Do not expose the thermostat to moisture, water, dust, and excessive heat.
This thermostat can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a
Installation Guide6
DEVIreg™ Opti
safe way and understand the hazards involved, by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the thermostat.
Cleaning and user maintenance shall not be made by children without supervision.
4 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the wall (typically 80-170 cm.).
The thermostat should not be placed in wet rooms. Thermostat must be placed outside zone
2. Place it in an adjacent room and use floor sen­sor only. Always place the thermostat according to local regulation on IP classes.
Do not place the thermostat on the inner side of a poorly insulated exterior wall.
7Installation Guide
DEVIreg™ Opti
12
Always install the thermostat at least 50 cm from windows and doors, due to draft, when using regulation in: floor and room mode or room alone mode.
Do not place the thermostat in a way that it will be exposed to direct sunlight.
Note: A floor sensor is recommended in all floor heating applications and mandatory to thin matsand under wooden floors to reduce the risk of overheating the floor.
• Place the floor sensor
in a protecting plastic conduit in the floor construction in an ap­propriate place, where the floor is not exposed to sunlight or draft from door openings.
• Equally distant and >2 cm from the heating cables on
both sides.
Installation Guide8
DEVIreg™ Opti
• The conduit should be flush with the floor surface, coun-
tersink the conduit if necessary and possible.
• Route the conduit to the connection box.
• The bending radius of the conduit must be min 50 mm.
Follow the steps below to mount the thermostat:
1. Unpack thermostat
2. Remove the front cover as showed
on Pic. 1.
3. Connect the thermostat accor-
ding to the connection diagram.
The screen of the heating cable must be connected to the earth
Made in P.R.C.
conductor of the power supply cable by using a separate con­nector.
Note: Always install the floor sensor in a conduit in the floor.
S2 S1 L
Max Load
13(1) ASensor
Danfoss A/S, 6430 Nordborg, Denmark
IP21
0T35
Ambient Temperature: 0-35°C Standby maximum 0.5W
DEVIreg™ Opti
Pic. 2
Pic. 1
N
N
LOADLLOAD
Mains 220-240V~