Devireg 550
Setting up your Devireg 550 programmable thermostat with
your devimat system
If the thermostat is displaying ‘CODE’,
initially you will ONLY be presented with
step 1 and step 4, set these as described
below.
Once you have either completed steps 1 and 4, or the
controller is displaying something other than ‘CODE’,
you must press and hold the button until the word
‘CODE’ is displayed and follow the steps below:
STEP 1 - Setup code
Rotate button to select code 0044 and
then press button once
STEP 6 - O periods
‘LO’ should be displayed, you should
rotate dial to select -30°C, then press
button
STEP 2 - Operating mode
Rotate button to select code ALO and
then press button once
STEP 3 - Adaptive function
Rotate button to select ‘AdAP’ and then
press button once
STEP 4 - Sensor selection
Rotate button to select ‘FS’ to activate the
oor sensor, then press button
(not rFs or rs)
STEP 5 - Maximum oor temp. selection
At ‘nt’ rotate button to select either of
the following temperature selection
maximum oor temperatures, then press
button
STEP 7 - Save settings
Save Settings - Press button once
(if the controller is now displaying ‘CODE’, disconnect
the power to the controller and then reconnect)
Now you can set the time and day on the controller.
If any steps are skipped, hold button until word ‘CODE’
is displayed to reset controller and start again at step 1
Press and hold button until is displayed in bottom
left corner. The display now shows the time and day
(number 1 represents Monday, number 7 is Sunday).
Rotate the dial to show the correct time and day of the
week and then press the button to save the correct time
setting and press button once.
Finally you can now set how you wish the controller to
operate.
Tiles on timber based oor 29°C
Tiles on concrete based oor 40°C
Timber covered oors (parquet etc.) 27°C
You can operate the controller in either Manual or Timer
Mode, by pressing the button you can toggle between
these two modes.

Manual Mode
In this mode the temperature set on the
display is maintained 24 hours a day,
i.e. no timing facility and therefore no
displayed. Whilst in manual mode, if you
rotate the dial to level 1.0 then turn the
dial vigorously further anti-clockwise,
the thermostat will switch o and display
‘OFF’.
Enter timer mode
Press and hold button until is
displayed in bottom right corner.
Select rst day
Rotate button to display the rst day you
wish to program and press button.
Continue
Rotate button to indicate next warm oor
start time. Press the button, rotate to the
end of the period and press button again.
Continue this through the whole week.
Save programme
To save programs, press and hold the
button to return to the normal display.
By pressing the button once you can
now toggle between manual and timer
modes.
Set oor level
The button now controls the heat level
of your Devimat system. The controller
can be adjusted to the required heat level
on a range from 1-10, level 10 being the
maximum oor heat. The displayed heat
level is what the controller will provide
at the times programmed. It is recommended that you initially set to level 5,
then adjust to suit.
First start time
Rotate button to indicate the start of the
rst time period when you want a warm
oor (i.e. 06:00) and then press the button
First end time
Rotate the button to highlight duration of
rst warm oor period, then press button
to indicate the end of rst time period (i.e.
07:30)
If you multiply the level number by 5 it
will give you the temperature in °C.
Do not set this higher than the maximum
oor temperature.
Part no. 890v01 07.04.2011