Danfoss Devireg 550 User guide

Devireg 550
Setting up your Devireg 550 programmable thermostat with your devimat system
If the thermostat is displaying ‘CODE’, initially you will ONLY be presented with step 1 and step 4, set these as described below.
Once you have either completed steps 1 and 4, or the controller is displaying something other than ‘CODE’, you must press and hold the button until the word ‘CODE’ is displayed and follow the steps below:
STEP 1 - Setup code
Rotate button to select code 0044 and then press button once
STEP 6 - O periods
‘LO’ should be displayed, you should rotate dial to select -30°C, then press button
STEP 2 - Operating mode
Rotate button to select code ALO and then press button once
STEP 3 - Adaptive function
Rotate button to select ‘AdAP’ and then press button once
STEP 4 - Sensor selection
Rotate button to select ‘FS’ to activate the oor sensor, then press button (not rFs or rs)
STEP 5 - Maximum oor temp. selection
At ‘nt’ rotate button to select either of the following temperature selection maximum oor temperatures, then press button
STEP 7 - Save settings
Save Settings - Press button once
(if the controller is now displaying ‘CODE’, disconnect the power to the controller and then reconnect)
Now you can set the time and day on the controller.
If any steps are skipped, hold button until word ‘CODE’ is displayed to reset controller and start again at step 1
Press and hold button until is displayed in bottom left corner. The display now shows the time and day (number 1 represents Monday, number 7 is Sunday). Rotate the dial to show the correct time and day of the week and then press the button to save the correct time setting and press button once.
Finally you can now set how you wish the controller to operate.
Tiles on timber based oor 29°C Tiles on concrete based oor 40°C Timber covered oors (parquet etc.) 27°C
You can operate the controller in either Manual or Timer Mode, by pressing the button you can toggle between these two modes.
Manual Mode
In this mode the temperature set on the display is maintained 24 hours a day, i.e. no timing facility and therefore no displayed. Whilst in manual mode, if you rotate the dial to level 1.0 then turn the dial vigorously further anti-clockwise, the thermostat will switch o and display ‘OFF’.
Enter timer mode
Press and hold button until is displayed in bottom right corner.
Select rst day
Rotate button to display the rst day you wish to program and press button.
Continue
Rotate button to indicate next warm oor start time. Press the button, rotate to the end of the period and press button again. Continue this through the whole week.
Save programme
To save programs, press and hold the button to return to the normal display. By pressing the button once you can now toggle between manual and timer modes.
Set oor level
The button now controls the heat level of your Devimat system. The controller can be adjusted to the required heat level on a range from 1-10, level 10 being the maximum oor heat. The displayed heat level is what the controller will provide at the times programmed. It is recom­mended that you initially set to level 5, then adjust to suit.
First start time
Rotate button to indicate the start of the rst time period when you want a warm oor (i.e. 06:00) and then press the button
First end time
Rotate the button to highlight duration of rst warm oor period, then press button to indicate the end of rst time period (i.e. 07:30)
If you multiply the level number by 5 it will give you the temperature in °C. Do not set this higher than the maximum oor temperature.
Part no. 890v01 07.04.2011