Danfoss DEVIreg 330 Operating guide

Installation Guide
DEVIreg™ 330 (-10 to +10°C)
Electronic Thermostat
EN
www.DEVI.com
DEVIreg™ 330 (-10 to +10°C)
Table of Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Technical Specications . . . . . . . . . . . . . . . . . . . . 4
1.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 Disposal Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1 Introduction
The thermostat has a button to adjust the temperature set­ting, with a scale from -10° to +10°C. An LED indicator shows standby periods (green light) and heating periods (red light).
More information on this product can also be found at: devireg.devi.com
3Installation Guide
DEVIreg™ 330 (-10 to +10°C)
1.1 Technical Specications
Operation voltage 220-240 V~, 50 Hz
Standby power consumption Max 0,25 W
Relay:
Resistive load Inductive load
Max 16 A / 3680 W @ 230 V cos φ= 0,3 max1A
Sensing units NTC 15 kOhm at 25 °C
Sensing values: 0 °C 25 °C 50 °C
42 kOhm 15 kOhm 6 kOhm
Hysteresis ± 0,2 °C
Ambient temperature 10 °C to +50 °C
Lowering in economy periods -5 °C
Temperature range -10 °C to +10 °C
Cable specication max 1x4 mm2 or 2x2,5 mm
Ball pressure temperature 75 °C
Pollution degree 2 (domestic use)
Type 1C
Storage temperature -20 °C to +65 °C
IP class 20
2
Installation Guide4
DEVIreg™ 330 (-10 to +10°C)
Protection class Class II
Dimensions 86 x 36 x 58 mm
Weight 83 g
The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use”:
• EN/IEC 60730-1 (general)
• EN/IEC 60730-2-9 (thermostat)
1.2 Safety Instructions
Make sure the mains supply to the thermostat is turned o before installation.
Please also note the following:
• The installation of the thermostat must be done by an authorized and qualied installer according to local regulations.
• The thermostat must be connected to a power supply via an all-pole disconnection switch.
• The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended.
• Always connect the thermostat to continuous power supply.
• Do not expose the thermostat to moisture, water, dust, and excessive heat.
5Installation Guide
DEVIreg™ 330 (-10 to +10°C)
2 Mounting Instructions
Please observe the following placement guidelines:
• Install the thermostat in an electric cabinet with DIN rail attachment or a separate DIN attachment accord­ing to local regulation on IP classes.
• Do not place the thermostat in a way that it will be exposed to direct sunlight.
Follow the steps below to mount the thermostat:
1. Click the thermostat on to the DIN rail attachment.
2. Connect the thermostat according to the connection diagram.
-10°C to
+10°C
Installation Guide6
DEVIreg™ 330 (-10 to +10°C)
N
L
PE
The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
Note: When you use the wire sensor for oor heating, always install the sensor in a conduit.
3. Turn on the power supply.
7Installation Guide
DEVIreg™ 330 (-10 to +10°C)
3 Warranty
4 Disposal Instruction
Installation Guide8
DEVIreg™ 330 (-10 to +10°C)
9Installation Guide
DEVIreg™ 330 (-10 to +10°C)
Installation Guide10
DEVIreg™ 330 (-10 to +10°C)
Danfoss A/S
Nordborgvej 81 6430 Nordborg, Syddanmark Denmark
Produced by Danfoss © 02/202108095476 & AQ087986468554en-020302
Product Documentation
5 703466 209219
DK EL 7224215302
SE EL 8581184
NO EL 5402659
FI SSTL 3531030
DK EL 7224215328
SE EL 8581188
NO EL 5402664
FI SSTL 3531034
220-240V~
50-60Hz~
+60 to +160˚C
DEVIreg 330 +60<>+160˚
140F1073
DEVIreg™ 330 (-10 °С to +10 °C)
140F1070
220-240V~
50-60Hz~
-10 to +10°C
16A/3680W@230V~
16A/3680W@230V~
570 3466209233
Designed in Denmark for Danfoss A/S