Installation Guide
DEVIreg™ 330 (-10 to +10°C)
Electronic Thermostat
EN
www.DEVI.com

DEVIreg™ 330 (-10 to +10°C)
Table of Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Technical Specications . . . . . . . . . . . . . . . . . . . . 4
1.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 Disposal Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1 Introduction
DEVIreg™ 330 is an electronic thermostat to be installed in
electric cabinets with DIN rail attachment. Used primarily for
controlling a lower temperature range as by frost protection.
The thermostat must be installed via an all-pole disconnection
switch. Either a wire sensor or an external air sensor must be
used to measure and control the desired temperature.
The thermostat has a button to adjust the temperature setting, with a scale from -10° to +10°C. An LED indicator shows
standby periods (green light) and heating periods (red light).
More information on this product can also be found at:
devireg.devi.com
3Installation Guide

DEVIreg™ 330 (-10 to +10°C)
1.1 Technical Specications
Operation voltage 220-240 V~, 50 Hz
Standby power consumption Max 0,25 W
Relay:
Resistive load
Inductive load
Max 16 A / 3680 W @ 230 V
cos φ= 0,3 max1A
Sensing units NTC 15 kOhm at 25 °C
Sensing values:
0 °C
25 °C
50 °C
42 kOhm
15 kOhm
6 kOhm
Hysteresis ± 0,2 °C
Ambient temperature 10 °C to +50 °C
Lowering in economy periods -5 °C
Temperature range -10 °C to +10 °C
Cable specication max 1x4 mm2 or 2x2,5 mm
Ball pressure temperature 75 °C
Pollution degree 2 (domestic use)
Type 1C
Storage temperature -20 °C to +65 °C
IP class 20
2