This material is to be used for research purposes only under the supervision of a technically qualified individual. The toxicological properties may have not been completely characterized. To determine your responsibilities under the EC Seventh amendment Directive 92 /32/EEC, please see the Regulatory Information Section. If this material has been supplied to you under the terms of a secrecy or non-analysis agreement, the information included in this MSDS is hereby identified as "Confidential Information."

Prepared according to Commission Regulation (EU) No 453/2010.

Section 1

Identification of substance/mixture and of the company/undertaking

1.1 Product Identifier

CPI(R)-2933F (IBC)- 160MPZ5402036P01B

Synonyms None.

1.2Relevant identified uses of the substance or mixture and (uses advised against) Relevant identified uses (see section 7.3 for information on REACH registered uses)

Refrigeration Lubricants.

1.3Details of the supplier of the safety data sheet

CPI Fluid Engineering

2300 James Savage Rd.

Midland, MI 48642

Phone: 989-496-3780

Fax: 989-496-0316

E-mail contact

EUSDS@lubrizol.com (Lubrizol Safety Data Sheets can be obtained at www.mylubrizol.com)

1.4 Emergency Telephone number

FOR TRANSPORT EMERGENCY call CHEMTREC: (+1) 703-527-3887 (outside the U.S.), 1-800-424-9300 (in the U.S.)

Section 2

Hazards Identification

2.1 Classification of the substance or mixture (EC) No 1272/2008

This product does not meet the classification requirements of the current European legislation.

67/548/EC or 1999/45/EC

This product does not meet the classification requirements of the current European legislation.

For a full text of R- and H- phrases: See section 16

2.2 Label elements (EC) No 1272/2008

Avoid release to the environment.

All disposal practices must be in accordance with local, national and international regulations.

Supplemental label information

None.

2.3Other hazards

None identified.

Section 3

Composition/Information on Ingredients

 

 

3.2 Mixtures

 

 

 

 

(EC) No 1272/2008

 

 

 

EC No.

Registration Number

Percentage (by wt.)

Name

Classification

204-881-4

01-2119565113-46

From 0 to 10.0 percent

2,6-Di-tert-butyl-p-cresol

Aquatic Acute 1; H400

Page 1 / 7

Danfoss CPI(R)-2933F Safety guide

CPI(R)-2933F (IBC) 5402036P01B [2014/7/21]

 

 

 

 

 

 

 

Aquatic Chronic 1; H410

67/548/EC or 1999/45/EC

 

 

 

EC No.

Registration Number

Percentage (by wt.)

Name

Classification

 

 

 

 

67/548/EC

204-881-4

01-2119565113-46

From 0 to 10.0 percent

2,6-Di-tert-butyl-p-cresol

N

 

 

 

 

R50/53

600, 700, 800 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only.

Section 4

First Aid Measures

4.1 Description of first aid measures

Skin

Wash with soap and water. Get medical attention if irritation develops. Launder contaminated clothing before reuse.

Eyes

Flush with water at least 30 minutes. Get medical attention if eye irritation develops or persists.

Inhaled

Remove exposed person to fresh air if adverse effects are observed.

Swallowed

DO NOT INDUCE VOMITING. Get immediate medical attention.

Advice for first-aid providers

When providing first aid always protect yourself against exposure to chemicals or blood born diseases by wearing gloves, masks and eye protection. After providing first aid wash your exposed skin with soap and water.

4.2Most important symptoms and effects, both acute and delayed

See section 11.

4.3Indication of any immediate medical attention and special treatment needed

Note to physician: Treat symptomatically.

Section 5

Fire Fighting Measures

5.1 Extinguishing Media

CO2, dry chemical, or foam. Water can be used to cool and protect exposed material.

5.2Special hazards arising from substance or mixture

See section 10 for additional information.

5.3Advice for firefighters

Recommend wearing self-contained breathing apparatus.

Section 6 Accidental Release Measures

6.1 Personal precautions, protective equipment and emergency procedures

Personal protective equipment must be worn. Ventilate area if spilled in a confined space or other poorly ventilated area.

6.2 Environmental precautions

Take precautions to avoid release to the environment. Prevent from entering into soil, ditches, sewers, waterways and/or groundwater.

6.3 Methods and material for containment and cleaning up

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

6.4 Reference to other sections

See sections 8 and 13 for additional information.

Section 7

Handling and Storage

7.1 Precautions for safe handling

Keep containers closed when not in use. Do not discharge into drains or the environment, dispose to an authorized waste collection point. Use appropriate containment to avoid environmental contamination. Wash thoroughly after handling. Launder contaminated clothing before reuse. Empty container contains product residue which may exhibit hazards of product. Dispose of packaging or containers in accordance with local, regional, national and international regulations.

Page 2 / 7

CPI(R)-2933F (IBC) 5402036P01B [2014/7/21]

Pumping Temperature

Not determined.

Maximum Handling Temperature

Not determined.

Maximum Loading Temperature

Not determined.

7.2 Conditions for safe storage, including any incompatibilites

Take precautions to avoid release to the environment. See section 10 for incompatible materials.

Maximum Storage Temperature

Not determined.

7.3 Specific end use(s)

End uses are listed in an attached exposure scenario when one is required.

Section 8

Exposure Controls/Personal Protection

 

 

8.1 Control parameters

 

 

 

Country

Substance

Long Term (8 Hours T.W.A.)

Short Term (15 mins.)

Austria

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

N/E

Denmark

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

N/E

Finland

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

20 mg/cu. M

France

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

N/E

Greece

Butyl-hydroxyl-toluene

10 mg/cu. M

N/E

Ireland

2,6-Ditertiary-butyl-para-cresol

10 mg/cu. M

N/E

Portugal

2,6-Di-tert-butyl-p-cresol

2 mg/cu. M

N/E

Slovenia

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

N/E

Switzerland

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

40 mg/cu. M

Germany (TRGS 900)

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

N/E

UK

2,6-Di-tert-butyl-p-cresol

10 mg/cu. M

30 mg/cu. M

Other Exposure Limits

Contains synthetic basestock. Under conditions which may generate mists, observe the OSHA PEL of 5 mg per cubic meter, ACGIH TWA of 5 mg per cubic meter for mineral oil mists.

8.2 Exposure controls

Use with adequate ventilation.

Eye/face protection

Safety Glasses.

Skin protection

Neoprene.

Long sleeve shirt is recommended. Launder contaminated clothing before reuse.

Respiratory Protection

Use respirator with a combination organic vapor and high efficiency filter cartridge if recommended exposure limit is exceeded. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites.

Hygiene Measures

Wash thoroughly after handling this product.

Environmental exposure controls

See section 6 for details.

Section 9

Physical and Chemical Properties

9.1 Information on basic physical and chemical properties

Appearance

Clear to yellow liquid.

Odour

Mild

Odour Threshold

Not determined.

pH

Not determined.

Melting / Freezing

Not determined.

Point

 

Boiling Point

Not determined.

Boiling Point Range

Not determined.

Page 3 / 7