Danfoss CP702-2 Technical Information

Logic Elements Technical Information
11
14
17
20
3
2
1
Spool Type CP702-2
OPERATION
The CP702-2 is a 16-size, normally closed, vent-to-open, spring­biased dierential-sensing logic element. It will modulate ow from 1 to 2 based on the spring control pressure, inlet pressure at port 1, and pilot pressure at port 3.
APPLICATION
Common applications include: pump unloading, pilot-operated relief valve (mechanical or proportional), sequence valve and selector circuit. Eective use of logic elements is a key to designing cost-eective circuits, and is limited only by the imagination of the designer.
SPECIFICATION
Rated pressure 210 bar [3045 psi]
Rated ow at 7 bar
[100 psi]
Weight 0.38 kg [0.83 lb]
Cavity SDC16-3S
190 l/min
[50 US gal/min]
SCHEMATIC
Theoretical performance
PERFORMANCE CURVE
psi bar
3
4
5
6
87
58
29
14
12
10
8
6
Press ure drop
4
2
Fully opened
BC332375783111en-000101 • February 2020
0
80L/min
160 240 320 400
21.1US gal/min
Flow
42.3 63.4 84.5 105.7
LE - 37
DIMENSION
Logic Elements Technical Information
Spool Type CP702-2
Cross-sectional viewmm [in]
h 1.50 in
122-136 N.m
1
23
1-5/16-12 UN
54.6
[2.15]
39.6
[1.56]
t
[90-100 lbf.ft]
EXAMPLE CIRCUITS
ORDERING INFORMATION
CP702-2-B-16S -080
Seals
B=Buna-N 120033 V=Viton 120034
Housing and ports
0= No housing No housing 6B = AL, 3/4 BSP CP16-3S-6B/2B 8B = AL, 1 BSP CP16-3S-8B/2B =
12S = AL, #12 SAE CP16-3S-12S/4S = #4 SAE 16S =#16 SAE CP16-3S-12S/4S = #4 SAE
Other housings available
AL,
Seal kit
Housing P/N Pilot port
= 1/4 BSP
1/4 BSP
Differential Control Pressure
bar[psi] 040=2.8[40] 080=5.5[80] 110=7.6[110] 150=10.3 [150] 170=11.7 [170]
BC332375783111en-000101 • February 2020
LE - 38