Danfoss CF-RS, CF-RP, CF-RD, CF-RF Data sheet

Data Sheet
CF2+ Wireless Floor Heating Control System
CF-Rx Room Thermostats
Application
CF-RS CF-RP CF-RD CF-RF
CF-Rx thermostats communicate with the CF-MC Master Controller via 2-way wireless transmission. All thermostats includes a Link Test function for easy status indication of the wireless signal and a LED warning for low battery.
The room thermostats are available in 4 versions:
CF-RS Standard Thermostat
• Easy wireless assignment with Link Test to Master Controller CF-MC.
• Min. and max. limitation of temperature set­tings.
• Powered by 2 x AA Alkaline 1.5V batteries.
• LED indication for low battery.
CF-RP Public (tamperproof) Thermostat
• Easy wireless assignment with Link Test to Master Controller CF-MC.
• Min. and max. limitation of temperature set­tings.
• Powered by 2 x AA Alkaline 1.5V batteries.
• LED indication for low battery.
• Hidden set point adjustment for use in child­rens rooms, schools, oce buildings etc.
• Powered by 2 x AA Alkaline 1.5V batteries.
• LED indication for low battery.
• Digital display showing actual or set room temperature.
CF-RF Display Thermostat with InfraRed oor sensor
• Easy wireless assignment with Link Test to Master Controller CF-MC.
• Min. and max. limitation of temperature set­tings.
• Powered by 2 x AA Alkaline 1.5V batteries.
• LED indication for low battery.
• Digital display showing actual or set room temperature.
• InfraRed oor sensor for minimum and maxi­mum oor surface temperature limitation.
CF-RF
VDSPL202
CF-RD Display Thermostat
• Easy wireless assignment with Link Test to Master Controller CF-MC.
• Min. and max. limitation of temperature set­tings.
© Danfoss | FHH | 2015.09 | 1
Ordering
ErP
4
111 mm
66 mm
21 mm
Product Typ e Code no.
Standard room thermostat CF-RS 088U0210
Public (tamperproof) room thermostat CF-RP 088U0211
Room thermostat with digital display CF-RD 088U0214
Room thermostat with digital display and InfraRed oor sensor CF-RF 088U0215
Technical specications
Supply voltage 2 x 1.5 Alkaline batteries AA
Battery life
Transmission frequency 868.42 MHz
Transmission range up to 30 m (in normal buildings)
Transmission power < 1 mW
Temperature setting range 5-35° C
Approvals CE
Standard EN 60730
Directives R&T TE, EMC
IP class 21
ErP class
Weight 120 g
CF-RS & CF-RP: 3-4 years CF-RD & CF-RF: 1-3 years
(2%)
Dimensions
Danfoss A/S
Floor Heating Hydronics • Ulvehavevej 61 • DK-7100 Vejle • Denmark • Phone: +45 7488 8500 • Fax: +45 7488 8501 heating@danfoss.com • www.oorheating.danfoss.com
Danfoss ca n accept no respons ibility for pos sible errors in ca talogues, bro chures and other pr inted material. Da nfoss reserves t he right to alter its p roducts with out notice. This als o applies to produ cts already o n order provided t hat such alteratio ns can be made with out subsequenti al changes being n ecessary in spe cications alr eady agreed. All trade marks in this mate rial are proper ty of the respec tive companies . Danfoss and the Dan foss logotyp e are trademark s of Danfoss A/S. Al l rights reserv ed.
2 | © Danfoss | Danfoss | FHH | 2015.09
VDSPL202