Instrukcja montażu
Sterownik CCR2+
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sterownik nadrzędny |
Jednostka podrzędna |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
POLSKI |
CCR2+ Sterownik dezynfekcji termicznej oraz rejestrator temperatur |
www.ogrzewanie.danfoss.com |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
© Danfoss | 2018.11 |
VI.D3.C1.49 | 1 |
Sterownik CCR2+
|
|
|
|
|
|
|
1 |
2 |
7 |
8 |
9 |
10 |
19 |
20 |
|
||||||||||||||
|
|
LBus |
C |
C |
C |
C |
C |
C |
24VDC |
RS485 |
A1-4 |
V1-4 |
V5-8 |
V9-12 |
V13-16 |
V17-20 |
S0
CCR2+ Controller
B1-3 S0 |
S1-4 |
S5-8 |
S9-12 |
S13-16 |
S17-20 |
G |
G |
G |
G |
G |
G |
TCP/IP
RJ45
S1 |
S2 |
S7 |
S8 |
S9 |
S10 |
S19 |
S20 |
V1 |
V2 |
V7 |
V8 |
V9 |
V10 |
V19 |
V20 |
TWA |
TWA |
TWA |
TWA |
TWA |
TWA |
TWA |
TWA |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
24 VDC
Rys. 1 CCR2+ & ESMC |
Rys. 2 Instalacja ze sterownikiem CCR2+ (do 20 pionów/obiegów) |
|
ECL...
M |
S |
M
S
S |
S |
S |
S |
1 |
2 |
19 |
20 |
21 |
... |
35 |
36 |
S1 |
S2 |
S19 |
S20 |
S21 |
S... |
S35 |
S36 |
V1 |
V2 |
V19 |
V20 |
V21 |
V... |
V35 |
V36 |
TWA |
TWA |
TWA |
TWA |
TWA |
TWA |
TWA |
TWA |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
MTCV |
24 VDC |
24 VDC |
Rys. 3a Instalacja ze sterownikiem CCR2+ (jednostka nadrzędna) oraz jednoską podrzędną CCR+ (więcej niż 21 pionów)
|
TVM |
1 |
TVM |
2 |
TVM |
7 |
TVM |
8 |
TVM |
9 |
TVM |
... |
TVM |
19 |
TVM |
20 |
ECL... |
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
TVM |
|
|
S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S1 |
|
S2 |
|
S7 |
|
S8 |
|
S9 |
S... |
|
S19 |
|
S20 |
|
S |
|
V1 |
|
V2 |
|
V7 |
|
V8 |
|
V9 |
|
V... |
|
V19 |
V20 |
|
|
TWA |
|
TWA |
|
TWA |
|
TWA |
|
TWA |
|
TWA |
|
TWA |
TWA |
|
M |
|
|
MTCV |
|
MTCV |
|
MTCV |
|
MTCV |
|
MTCV |
MTCV |
|
MTCV |
|
MTCV |
|
|
|
|
|
|
|
|
|
||||||||
S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24 VDC |
|
|
|
Rys. 3b
2 | © Danfoss | 2018.11 |
VI.D3.C1.49 |
Sterownik CCR2+
G 24VDC
<![if ! IE]> <![endif]>POWER |
<![if ! IE]> <![endif]>Master |
G
Lbus
G
B
A
<![endif]>Module 0
C
O4
O3
O2
O1
<![endif]>Module 1
C
V4
V3
V2
V1
<![endif]>Module 2
C
V8
V7
V6
V5
<![endif]>Module 3
C
V12
V11
V10
V9
<![endif]>Module 4
C
V16
V15
V14
V13
<![endif]>Module 5
C
V20
V19
V18
V17
|
|
105 mm |
|
|
|
|
|
|
|
|
60 mm |
|
|||
|
|
|
|
|
|
|
|
|
|
|
50 mm |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
0V |
LBus |
C |
C |
C |
C |
C |
C |
|
|
|
|
|
|
|
|
24VDC |
RS485 |
O1- 4 |
V1- 4 |
V5-8 |
V9-12 |
V13-16 |
V17-20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>122mm |
|
|
<![if ! IE]> <![endif]>MADEIN POLAND |
|
<![if ! IE]> <![endif]>Danfoss A/S |
<![if ! IE]> <![endif]>Nordborg, Denmark |
|
CCR2+ Controller |
|
|
|
|
|
<![if ! IE]> <![endif]>90mm |
<![if ! IE]> <![endif]>45mm |
<![if ! IE]> <![endif]>Disinfection ProcessController |
<![if ! IE]> <![endif]>CCR2+ |
<![if ! IE]> <![endif]>20171213V2.40 |
<![if ! IE]> <![endif]>003Z3851 24VDCSupply RoHS |
<![if ! IE]> <![endif]>6430 |
<![if ! IE]> <![endif]>36mm |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
TCP/IP |
B1-B3 S0 |
S1-4 |
S5-8 |
S9-12 |
S13-16 |
S17-20 |
|
|
|
|
|
|
|
|
|
LAN |
G |
G |
G |
G |
G |
G |
|
|
|
|
|
|
|
|
|
TCP/IP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RJ45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rys. 4a Schemat okablowania - sterownik nadrzędny CCR2+
<![endif]>POWER
<![endif]>Master
TCP/IP
RJ45
<![endif]>Module 0
B1
B2
B3
S0
G
<![endif]>Module 1
S1
S2
S3
S4
G
<![endif]>Module 2
S5
S6
S7
S8
G
<![endif]>Module 3
S9
S10
S11
S12
G
<![endif]>Module 4
S13
S14
S15
S16
G
<![endif]>Module 5
S17
S18
S19
S20
G
Złącze / port |
Opis |
||
|
|
|
|
0V |
0V |
– masa (-) zasilanie |
|
24VDC |
24 VDC(+) zasilanie |
||
|
G – masa portu Lbus (do rozbudowy systemu) |
||
Lbus |
Lbus – port Lbus (do rozbudowy systemu) |
||
G – masa (Modbus RS 485) |
|||
RS485 |
|||
B – port B (Modbus RS 485) |
|||
|
|||
|
A - port A (Modbus RS 485) |
||
C |
C – wspólny port dedykowany wyjściom O1-O4 |
||
O1,..,O4 |
O1 |
- trwająca dezynfekcja |
|
|
O2 |
- start dezynfekcji następnego CCR2+/jednostki podrzędnej |
|
|
O3 |
- zakończona dezynfekcja |
|
|
O4 |
- alarm |
|
C |
C – wspólny port dedykowany napędom V1-4 |
||
V1-4 |
V1..V4 – wyjścia do napędów |
||
C |
C – wspólny port dedykowany napędom V5-8 |
||
V5-8 |
V5..V8 – wyjścia do napędów |
||
C |
C – wspólny port dedykowany napędom V9-12 |
||
V9-12 |
V9..V12 – wyjścia do napędów |
Złącze / port |
Opis |
|
|
|
|
C |
C – wspólny port dedykowany napędom V13-16 |
|
V13-16 |
V13..V16 – wyjścia do napędów |
|
C |
C – wspólny port dedykowany napędom V17-20 |
|
V17-20 |
V17..V20 –wyjścia do napędów |
|
TCP/IP, LAN |
Port TCP/IP lub Modbus IP |
|
|
|
|
B1-3, S0 |
B1,B2, B3 - zdefiniowane wejścia |
|
S0 – czujnik temperatury zasilania instalacji |
||
G |
||
G – wspólna masa dla wejść lub czujników temperatury |
||
|
||
S1-4 |
S1..S4 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury S1-4 |
|
S5-8 |
S5..S8 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury S5-8 |
|
S9-12 |
S9..S12 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury S9-12 |
|
S13-16 |
S13..S16 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury S13-16 |
|
S17-20 |
S17..S20 –wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury S17-20 |
VI.D3.C1.49 |
© Danfoss | 2018.11 | 3 |
Sterownik CCR2+
<![if ! IE]> <![endif]>ZASILANIE |
|
<![if ! IE]> <![endif]>CCR+ |
|
|
|
<![if ! IE]> <![endif]>BMS |
<![if ! IE]> <![endif]>Jednostka podrzędna |
|
|
KO3 |
|
|
|
|
|
|
KO4 |
|
|
|
Alarm |
|
|
|
|
|
Zakończona dezynfekcja |
|
|
|
|
Start dezynfekcji następnego |
KO2 |
|
|
|
|
|
|
||
|
|
CCR2+/jednostki podrzędnej KO1 |
|
|
|
|
|
|
Trwająca dezynfekcja |
|
|
|
|
|
24VDC |
|
|
|
|
|
0V |
|
|
Napędy zaworów zamontowanych na pionach V1...V20
Wyjścia otwartego kolektora podłączyć do 0V
V2 |
V4 |
V6 |
V8 |
|
V10 |
V12 |
V14 |
V16 |
V18 |
V20 |
||
V1 |
V3 |
V5 |
V7 |
V9 |
V11 |
V13 |
V15 |
V17 |
V19 |
24VDC0VDC
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>B G G |
|||||||
<![if ! IE]> <![endif]>A |
|
|
<![if ! IE]> <![endif]>Lbus |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>O3 |
<![if ! IE]> <![endif]>C |
<![if ! IE]> <![endif]>V1 |
<![if ! IE]> <![endif]>V3 |
<![if ! IE]> <![endif]>C |
<![if ! IE]> <![endif]>V5 |
<![if ! IE]> <![endif]>V8 |
|
<![if ! IE]> <![endif]>V10 V11 V12 |
<![if ! IE]> <![endif]>V13 V14 V15 V16 |
<![if ! IE]> <![endif]>V17 V18 V19 V20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||
<![if ! IE]> <![endif]>O1 O2 |
<![if ! IE]> <![endif]>O4 |
|
<![if ! IE]> <![endif]>V2 |
<![if ! IE]> <![endif]>V4 |
|
<![if ! IE]> <![endif]>V6 V7 |
<![if ! IE]> <![endif]>C |
<![if ! IE]> <![endif]>V9 |
<![if ! IE]> <![endif]>C |
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>C |
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>C |
Moduł |
Moduł |
Pusty |
Moduł 0 |
Moduł 1 |
Moduł 2 |
Moduł 3 |
Moduł 4 |
Moduł 5 |
zasilania |
sterownika |
socket |
Wejść / Wyjść |
Wejść / Wyjść |
Wejść / Wyjść |
Wejść / Wyjść |
Wejść / Wyjść |
Wejść / Wyjść |
|
głównego |
|
|
|
|
|
|
|
TCP/IP - LAN
<![endif]>B1 B2 B3 S0 G S1 S2 S3 S4 G S5 S6 S7 S8 G S9 S10 S11 S12 G S13 S14 S15 S16 G S17 S18 S19 S20 G
WEB SERVER BMS TCP/IP ETHERNET INTERNET
<![endif]>S0
<![if ! IE]><![endif]>B3
<![if ! IE]><![endif]>B2
<![if ! IE]><![endif]>B1
B1 - start dez. |
S0 - główny |
Czujniki temperatury pionów S1...S20 |
B2 - stop dez. |
czujnik temp. |
Typ - PT1000 |
B3 - alarm zew. |
PT1000 |
|
Rys. 4b Schemat okablowania sterownika nadrzędnego CCR2+ (Master Controller)
4 | © Danfoss | 2018.11 |
VI.D3.C1.49 |
Sterownik CCR2+
G 24VDC
<![if ! IE]><![endif]>Power
<![endif]>Module 6
C
V24
V23
V22
V21
<![endif]>Module 7
C
V28
V27
V26
V25
<![endif]>Module 8
C
V32
V31
V30
V29
<![endif]>Module 9
C
V36
V35
V34
V33
|
105 mm |
|
|
|
|
|
|
60 mm |
|
|||
|
|
|
|
|
|
|
|
50 mm |
|
|||
|
|
|
|
|
|
|
|
|
|
|
||
OV |
C |
C |
C |
C |
|
|
|
|
|
|
|
|
24VDC |
V21-24 |
V25-28 |
V29-32 |
V33-36 |
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>122mm |
|
|
<![if ! IE]> <![endif]>MADEINPOLAND |
|
<![if ! IE]> <![endif]>DanfossA/S |
<![if ! IE]> <![endif]>Nordborg,Denmark |
|
CCR+ Slave |
|
|
|
<![if ! IE]> <![endif]>90mm |
<![if ! IE]> <![endif]>45mm |
<![if ! IE]> <![endif]>CCR+SlaveUnit |
<![if ! IE]> <![endif]>SlaveCCR+Unit |
<![if ! IE]> <![endif]>20171212VS.12 |
003Z3852 Supply24VDC RoHS |
<![if ! IE]> <![endif]>6430 |
<![if ! IE]> <![endif]>36mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G |
S21-24 |
S25-28 |
S29-32 |
S33-36 |
|
|
|
|
|
|
|
|
LBus |
G |
G |
G |
G |
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>Slave |
G |
Lbus |
Rys. 5 Schemat okablowania - jednostki podrzędnej CCR+
Złącze / port |
Opis |
0V |
0V – masa zasilania (-) |
24VDC |
24 VDC(+) zasilanie |
CC – wspólny port dedykowany napędom
V21-24 |
V21..V24 – wyjścia do napędów |
CC – wspólny port dedykowany napędom
V24-28 |
V24..V28 – wyjścia do napędów |
CC – wspólny port dedykowany napędom
V29-32 |
V29..V32 – wyjścia do napędów |
CC – wspólny port dedykowany napędom
V30-36 |
V33..V36 – wyjścia do napędów |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>0 |
S21 |
<![if ! IE]> <![endif]>0 |
S25 |
S29 |
<![if ! IE]> <![endif]>2 |
S33 |
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||
|
|
|
|
<![if ! IE]> <![endif]>1 |
|
|
|
|
S35 |
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||
<![if ! IE]> <![endif]>Module |
S23Module |
S27Module |
S31Module |
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||
|
|
S22 |
|
|
|
S26 |
S30 |
|
|
|
S34 |
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
S24 |
|
|
|
S28 |
S32 |
|
|
|
S36 |
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
G |
|
|
|
G |
G |
|
|
|
G |
|
|
|
|
|
|
|
|
|
|
Złącze / port |
Opis |
|
|
|
|
Lbus |
G – masa portu Lbus (do rozbudowy systemu) |
|
Lbus – port Lbus (do rozbudowy systemu) |
||
|
||
S21-24 |
S21..S24 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury |
|
S25-28 |
S25..S28 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury |
|
S29-32 |
S29..S32 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury |
|
S33-36 |
S33..S36 – wejścia czujników temperatury |
|
G |
G – wspólna masa dla czujników temperatury |
VI.D3.C1.49 |
© Danfoss | 2018.11 | 5 |