Danfoss C118-C Data sheet

MAKING MODERN LIVING POSSIBLE
Save $120
20%
C118-C Condenser
For increased chiller prots
Innovative | Optimised | Low hold-up volume | High heat transfer | Compact
reduction in refrigerant
reduction in refrigerant
charge compared with a traditional BPHE. This new condenser is the ideal solution to help you meet the world`s climate and energy aspirations.
per heat exchanger
per heat exchanger
on refrigerant because of the C118-C’s low hold-up volume.
www.danfoss.com
C118 - C
Micro Plate Heat Exchanger
INTRODUCTION
KEY FEATURES
Q4 Q1
Q4 Q1
519/ 2 0.4”
613/ 2 4.1”
Q3 Q2
Q3 Q2
98/ 3.9”
18 6/ 7. 3”
11.5+1.74 x n
0.45+0.07 x n
H1 H4
H1 H4
H2 H3
H2 H3
29/4 8 (1.1”/1.9 ”)
The C118-C is a condenser optimised for R407C for use in high-eciency chillers with capacities of 40-200 kW/10-55 Rt. The heat exchanger
features innovative Micro Plate technology that improves heat transfer and reduces the amount of material used.
To meet demands for higher seasonal eciency, the C118-C is designed to work eciently and increase comfort in modern buildings with­out increasing the carbon footprint. Helping chillers perform more eciently, it reduces both energy costs and environmental impact.
The low hold-up volume reduces the system refrigerant charge and offers valuable savings.
• Minimal hold-up volume: Less refrigerant charge.
• High heat transfer: For more ecient chillers.
• Smaller footprint: Enabling more compact chillers.
• Reduced CO
footprint: Environmentally friendly with high heat transfer and minimal refrigerant charge.
2
TECHNICAL DATA
n = NUMBER O F PLATES
Min. working temperature: -196°C/-320°F Max. working temperature: 200°C/390°F Max. working pressure: 30 bar/435 psi Hold-up volume: Q1-Q2/ Q3-Q4 (l): 0.151×n/2 / 0.151×(n-2)/2 (ft
3
): 0.005×n/2 / 0.005×(n-2)/2
Weight: 5.95kg+0.26×n (13.13lb+0.57×n) Max. no. of plates: 200
STANDARD MATERIALS
Cover plates: AISI 304 Connections: AISI 304
Plates: AISI 316 Brazing filler: Pure copper
Other material combinations are available on request. Please contact your Danfoss sales representative for more information.
STANDARD CONNECTIONS
Standard connections as per below are optimised for this product as condenser in chiller system. For other connections, please contact your Danfoss representative.
Q3 (Refrigerant outlet): soldering 5/8”, 3/4”, 7/8” or 1 1/8” Q4 (Refrigerant inlet): soldering 1 1/8”, 1 3/8”, 1 5/8” or 2 1/8” Q1-Q2 (Water side): External threaded 1 1/2”, 2” or Victaulic 2”
THIRD PART APPROVALS
ACCESSORIES – STUD BOLTS
ACCESSIBILITY
CORRESPONDING
Europe: Pressure Equipment Directive (PED). America: Underwriters Laboratory Inc (UL). The third party approvals stated are standard for all our products. For details of other existing approvals or to discuss how we can meet your local needs, please contact your Danfoss representative.
Stud bolts on front and/or back cover plates for mounting support are available upon request. Contact your Danfoss sales representative for further information.
We will help you set up a logistics solution that will meet your needs.
A corresponding Micro Plate heat exchanger for evaporator duties (C118-E) is also available.
EVAPORATORS
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reser ves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without consequent changes being necessar y in specifications already agreed. All trademarks in this material are the property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A /S. All rights reser ved.
520H7053 DKQB.PD.310.N3.22
produced by M almøresund, ww w.malmoresund.se, p hoto by Lars Owesson, w ww.owesson.s e, November 2012
Loading...