BD250/250GH
Direct Current Twin Compressor
R134a
12 - 24V
General
Code number (without electronic units) 101Z0500
Electronic unit 101N0290, 28 pcs: 101N0291
Remote kit (2 pcs. required) 105N9210
Approved compressor - electronic unit combinations refer to Instructions for 101N0290
Additional approvals e4, C-Tick
Compressors on pallet 40
Application
Application LBP/MBP/HBP
Evaporating temperature °C -25 to 15
Voltage/max. voltage VDC 12-24/31.5
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S S S
38°C S S S
43°C S S S
Remarks on application:
Motor
Motor type Variable speed
Resistance, all 3 windings (25°C) Ω 1.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 600
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 8.8/2 x 0.3
°C 60 (70)
3
3
3
2 x 2.50
400 (polyolester)
2 x 870
S = Static cooling normally suffi cient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally suffi cent
– = not applicable in this area
Standard battery protection settings
Voltage 12V 24V
Cut out VDC 10.4 22.8
Cut in VDC 11.7 24.2
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.2 | 41.5°
Process connector location/I.D. mm | angle D 6.2 | 45°
Discharge connector location/I.D. mm | angle E 5.0 | 21°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks
June 2011 DEHC.ED.100.B7.02 / 520N0956 1/2
(refer to 101N0290 Instructions for optional settings)
B 135
B1 128
B2 73
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
rpm \ °C -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15
2,500 76.0 85.1 105 139 181 213 231 290 358 392 438 529
3,100 92.5 103 126 168 217 255 277 347 429 469 524 633
3,800 112 125 153 203 262 308 333 417 514 562 627 757
4,400 126 141 174 231 299 349 378 471 580 633 705 849
Capacity (ASHRAE LBP) 12V DC, static cooling watt
rpm \ °C -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15
2,500 94.0 105 129 172 224 264 286 359 444 486 544 658
3,100 114 128 156 207 269 316 343 430 532 582 651 787
3,800 138 155 189 251 325 381 413 517 638 698 779 942
4,400 156 175 216 286 370 433 468 584 719 785 876 1057
Power consumption 12V DC, static cooling watt
rpm \ °C -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15
2,500 81.5 86.9 97.8 115 134 146 152 171 189 197 207 224
3,100 102 108 121 141 163 179 187 211 237 248 263 291
3,800 126 134 150 176 203 222 233 265 300 316 338 380
4,400 145 155 175 206 239 263 275 314 358 379 406* 460*
Current consumption (for 24V applications the following must be halfed) A
rpm \ °C -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15
2,500 6.79 7.24 8.15 9.61 11.12 12.15 12.68 14.24 15.79 16.45 17.28 18.69
3,100 8.46 8.99 10.07 11.79 13.61 14.88 15.54 17.58 19.71 20.68 21.93 24.25
3,800 10.51 11.18 12.52 14.65 16.94 18.54 19.40 22.07 24.99 26.35 28.17 31.66
4,400 12.11 12.95 14.60 17.19 19.94 21.88 22.93 26.20 29.82 31.54 33.85 38.35
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °C -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15
2,500 0.93 0.98 1.07 1.21 1.36 1.46 1.52 1.69 1.89 1.98 2.11 2.36
3,100 0.91 0.96 1.05 1.18 1.33 1.43 1.48 1.64 1.81 1.89 1.99 2.17
3,800 0.89 0.93 1.02 1.15 1.29 1.38 1.43 1.57 1.72 1.78 1.86 1.99
4,400 0.87 0.91 0.99 1.12 1.25 1.33 1.37 1.50 1.62 1.67 1.74 1.85
COP (ASHRAE LBP) 12V DC, static cooling W/W
rpm \ °C -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15
2,500 1.16 1.21 1.33 1.50 1.68 1.82 1.89 2.11 2.36 2.48 2.64 2.96
3,100 1.13 1.18 1.30 1.47 1.65 1.78 1.85 2.05 2.26 2.36 2.49 2.73
3,800 1.10 1.15 1.26 1.43 1.60 1.72 1.78 1.96 2.14 2.22 2.32 2.50
4,400 1.07 1.13 1.23 1.39 1.55 1.65 1.71 1.87 2.02 2.09 2.17 2.31
* Possible thermal cut-out of electronic unit due to heavy loaded refrigeration system.
Test conditions EN 12900/CECOMAF ASHRAE LBP
Condensing temperature 55°C 54.4°C
Ambient temperature 32°C 32°C
Suction gas temperature 32°C 32°C
Liquid temperature no subcooling 32°C
Operational errors errors shown by LED (optional)
Error
code
5
Thermal cut-out of electronic unit
(If the refrigeration system has been too hea vi ly
loaded, or if the ambient tem pe ra ture is high, the
electronic unit will run too hot).
4
Minimum motor speed error
(If the refrigeration system is too heavily loaded,
the motor cannot maintain minimum speed at
approximately 2,450 rpm).
3
Motor start error
(The rotor is blocked or the differential pres-sure in
the refrigeration system is too high (>5 bar)).
2
Fan over-current cut-out
(The fan loads the electronic unit with more than
1A
).
1
peak
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
Compressor speed
Electronit unit
Code number
Resistor
(R1) [Ω]
calculated
values [rpm]
Motor
speed
Control
circuit
current
[mA]
0 AEO 6
101N0290
with AEO
203 2,500 5
451 3,100 4
867 3,800 3
1700 4,400 2
In AEO (Adaptive Energy Optimizing) speed mode the BD comressor will always adapt its speed to the actual cooling demand.
Wire Dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
[mm2] [Gauge] [m] [ft.] [m] [ft.]
2 wires
8 8 2.5 8 5 16
1 wire with terminal block
8 8 1 3 2 7
*Length between battery an electronic unit
2 wires
Accessories for BD250/250GH Code number
Bolt joint for one compressor Ø :16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø:1 6 m m 118-1919
Remote kit (without cable) 105N9210
1 wire with terminal block
Standard automoblie fuse 12V: 30A
DIN 7258
Main switch
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifi cations already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
24V: 15A
min. 30A
Not
deliverable
from Secop
2/2 Manufactured by Secop for DANFOSS - DEHC.ED.100.B7.02 / 520N0956 June 2011