Danfoss BD220CL Data sheet

BD220CL

Direct Current Compressor R404A/R507

12V DC - with 101N08xx Series Controllers

General

Code number (without electronic units)

 

 

102Z3020

 

Compressor module

 

 

101N0800, 30 pcs: 101N0801

Application module

 

 

101N0820, 24 pcs: 101N0821

Alternative (one interface only):

 

101N0830, 30 pcs: 101N0831

Electronic Unit (no fan connection/no twin option)

 

 

 

 

 

 

 

 

 

 

Approvals

 

 

 

 

 

Compressors on pallet

 

 

 

125

 

Application

 

 

 

 

 

 

Application

 

 

 

 

LBP

 

Evaporating temperature

 

°C

 

-45 to -5

 

Voltage range

 

 

VDC

 

9.6 - 17

 

Max. condensing temperature continuous (short) °C

 

50 (60)

 

Max. winding temperature continuous (short)

°C

 

125 (135)

 

Cooling requirements

 

 

 

 

 

Application

 

 

 

LBP

MBP

HBP

32°C

 

 

 

F1

38°C

 

 

 

F1

43°C

 

 

 

F1

Remarks on application:

 

 

 

 

 

- evaporator fan max. 200W

 

 

 

 

 

- condenser fan max. 100W

 

 

 

 

 

Motor

 

 

 

 

 

 

Motor type

 

 

 

variable speed

Resistance, all 3 windings (25°C)

 

0.1

 

Design

 

 

 

 

 

 

Displacement

 

 

cm3

 

3.86

 

Oil quantity (type)

 

cm3

280 (polyolester)

Maximum refrigerant charge

 

g

 

400

 

Free gas volume in compressor

cm3

 

1690

 

Weight - Compressor/Electronic unit

kg

7.9 / 0.33 / 0.28 (101N820)

Battery protection settings

 

 

 

 

 

Voltage

 

 

 

Min. value

Default

Max. value

Cut out

(0.1 steps)

 

VDC

9.6

10.4

17

Cut in diff.

(0.1 steps)

 

VDC

0.5

1.3

10

Dimensions

 

 

 

 

 

 

Height

 

 

mm

A

173

 

 

 

 

 

B

169

 

 

 

 

 

B1

 

 

 

 

 

B2

 

Suction connector

location/I.D. mm | angle

C

6.2 | 90°

 

 

 

material | comment

Cu-plated steel | Al cap

Process connector

location/I.D. mm | angle

D

6.2 | 31.5°

 

 

 

material | comment

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

5.0 | 28°

 

 

 

material | comment

Cu-plated steel | Al cap

Connector tolerance

 

I.D. mm

±0.09, on 5.0 +0.12/+0.20

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

July 2013

Manufactured by Secop for Danfoss - DEHC.ED.100.X2.02 / 520N1484

1/2

Danfoss BD220CL Data sheet

Capacity (EN 12900 Household/CECOMAF)

 

12V DC, fan cooling F1

watt

Operational errors

 

 

rpm \ °C

-45 -40 -35

-30

-25 -23.3 -20

-15

-10

-6.7

-5

0

Error

 

 

Error type

 

2,500

26,4

47,1

71,9

101

136

149

177

224

278

318

340

 

code

Can be read out in the software TOOL4COOL®

3,000

31,4

56,0

85,5

121

162

178

210

266

331

379

405

 

6

Thermostat failure

 

 

3,500

36,3

64,9

99,2

140

188

206

244

309

384

439

470

 

 

(If the NTC thermistor is short-circuit or has no connection,

4,000

40,8

73,1

112

158

212

232

275

349

433

495

530

 

5

the electronic unit will enter manual mode).

Capacity (ASHRAE LBP)

 

 

 

 

12V DC, fan cooling F1

watt

Thermal cut-out of electronic unit

 

 

 

 

 

(If the refrigeration system has been too hea­vily­ loaded,

rpm \ °C

-45

-40

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

 

 

or if the ambient tempe­ra­ture­ is high, the electronic unit

2,500

31

55

83

117

158

173

205

260

323

370

396

 

 

 

 

will run too hot).

 

 

3,000

36

65

99

140

188

206

244

310

385

441

472

 

4

Minimum motor speed error

 

3,500

42

75

115

162

218

239

284

360

447

512

547

 

 

(If the refrigeration system is too heavily loaded, the

4,000

47

85

130

183

246

270

320

405

504

577

617

 

 

motor cannot maintain minimum speed at approximately

Power consumption

 

 

 

 

 

12V DC, fan cooling F1

watt

 

1,850 rpm).

 

 

-35

-30

-25

-23.3

-20

3

Motor start error

 

 

rpm \ °C

-45

-40

-15

-10

-6.7

-5

0

 

(The rotor is blocked or the differential pressure in the

2,500

65.2

82.8

98.9

114

129

133

143

158

174

185

191

 

 

 

 

refrigeration system is too high).

 

3,000

75.2

96.0

115

134

152

158

170

190

210

225

233

 

2

Fan over-current cut-out

 

3,500

84.3

108

131

152

174

181

196

219

245

263

272

 

 

 

 

(The fan loads the electronic unit with too high current).

4,000

94.3

121

147

172

197

206

223

251

281

303

314

 

1

Battery protection cut-out

 

Current consumption

 

 

 

 

12V DC, fan cooling F1

A

 

-30

-25

-23.3

-20

 

(The voltage is outside the cut-out setting).

rpm \ °C

-45

-40

-35

-15

-10

-6.7

-5

0

Accessories for BD220CL

 

2,500

5.43

6.90

8.24

9.50

10.71 11.12 11.92 13.16 14.48 15.40 15.90

 

 

 

Mounting

 

 

 

Code number

3,000

6.27

8.00

9.62

11.16 12.67 13.19 14.20 15.81 17.53 18.75 19.42

 

 

 

 

 

Bolt joint for one compressor

Ø: 16 mm

118-1917

3,500

7.03

9.02

10.89 12.69 14.48 15.10 16.32 18.27 20.38 21.89 22.71

 

 

Bolt joint in quantities

Ø: 16 mm

118-1918

4,000

7.86

10.12 12.26 14.34 16.43 17.15 18.59 20.90 23.41 25.22 26.20

 

 

Snap-on in quantities

Ø: 16 mm

118-1919

COP (EN 12900 Household/CECOMAF)

 

12V DC, fan cooling F1

W/W

rpm \ °C

-45

-40

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

Electrical

 

 

Code number

(cables, sensors, etc.)

Single pack

I - Pack

2,500

0.41

0.57

0.73

0.89

1.06

1.12

1.23

1.42

1.60

1.72

1.78

 

 

One Wire/LIN gateway

105N9501

3,000

0.42

0.58

0.74

0.90

1.07

1.12

1.23

1.40

1.57

1.68

1.74

 

 

communication cable

105N9524

3,500

0.43

0.60

0.76

0.92

1.08

1.14

1.25

1.41

1.57

1.67

1.72

 

 

Bluetooth® gateway

105N9502

4,000

0.43

0.60

0.76

0.92

1.08

1.13

1.23

1.39

1.54

1.64

1.68

 

 

communication cable

105N9525

COP (ASHRAE LBP)

 

 

 

 

 

12V DC, fan cooling F1

W/W

 

 

 

 

 

Temperature sensor 470 mm

105N9612

105N9613, 200 pcs.

rpm \ °C

-45 -40 -35

-30

-25 -23.3 -20

-15

-10

-6.7

-5

0

Temperature sensor 1000 mm

105N9614

105N9615, 100 pcs.

2,500

0.47

0.66

0.84

1.03

1.23

1.30

1.43

1.65

1.86

2.00

2.07

 

Temperature sensor 1500 mm

105N9616

105N9617, 100 pcs.

3,000

0.48

0.68

0.86

1.05

1.24

1.30

1.43

1.63

1.83

1.96

2.02

 

Comm. cable, 1500 mm

105N9553, 80 pcs.

3,500

0.50

0.69

0.88

1.07

1.26

1.32

1.45

1.64

1.83

1.95

2.01

 

Comm. cable, 3000 mm

105N9554, 45 pcs.

4,000

0.50

0.70

0.88

1.06

1.25

1.31

1.43

1.62

1.79

1.91

1.96

 

Display cable, 1500 mm

105N9557, 65 pcs.

Test conditions

 

 

EN 12900/CECOMAF

 

ASHRAE LBP

 

Display cable, 3000 mm

105N9558, 35 pcs.

 

 

 

 

 

 

 

 

 

Condensing temperature

 

 

45°C

 

 

45°C

 

Not deliverable from Secop

 

 

Ambient temperature

 

 

 

32°C

 

 

32°C

 

Slow-blow fuse compressor module

60A

Suction gas temperature

 

 

32°C

 

 

32°C

 

Slow-blow fuse application module

30A

Liquid temperature

 

 

 

no subcooling

 

 

32°C

 

Main switch

 

 

rated to min. 100A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Legend, see Intructions for details.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A)

Application module 101N0820

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B)

Compressor module 101N0800, 12 V DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C)

Supply cables

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D)

Compressor communication cable assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E) Electronic unit 101N0830 (alternative)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

Mounting screws

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2)

Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3)

Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4)

Main switch

 

5) Evaporator fan

6) Condenser fan

7) Mechanical thermostat

8) NTC temperature sensor

9) NTC auxiliary temperature sensor

10)Compressor(s)

11) One Wire/LIN gateway comm. interface

12)Modbus-compatible device

13)Bluetooth® gateway comm. interface

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.100.X2.02 / 520N1484