BD1.4F-VSD-HD
Heavy Duty
Direct Current Compressor
R134a, 12-24V DC
General
Code number (without electronic units) 109Z0251
Electronic unit - Variable Speed 101N2100, 30 pcs: 101N2101
Approvals –
Compressors on pallet 180
Application
Application LBP/MBP/HBP
Evaporating temperature °F -20 to 59
Voltage range VDC 9.6 - 17 / 19 - 34
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Application LBP MBP HBP
32°C S S S
38°C S S S
43°C S S S
Remarks on application:
HD (Heavy Duty) version of the BD1.4F-VSD which can handle extreme vibrations.
For more info please contact: mobile@secop.com.
°F 140 (158)
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Motor
Motor type permanet magnet, brushless DC
Speed variable speed
Resistance, all 3 windings (25°C) mΩ 210
Design
Displacement cu.in. 0.086
Oil quantity (type) .oz. 2.64 (polyolester)
Maximum refrigerant charge oz. 5.29
Free gas volume in compressor .oz. 17.60
Weight - Compressor/Electronic unit lbs. 4.63/0.24
Standard battery protection settings
Voltage (0.1 steps) Min. value Default Max. value
± 0.3V DC,
12V
all values
± 0.3V DC,
24V
all values
Dimensions
Height inch A 3.79
Suction connector location/I.D. inch | angle C 0.252-0259 | 25°
Process connector location/I.D. inch | angle D 0.252-0259 | 25°
Discharge connector location/I.D. inch | angle E 0.202-0.205 | 0°
Remarks: inch connectors
Cut out VDC 9.6 10.4 17
Cut in diff. VDC 0.5 1.3 10
Cut out VDC 19 21.3 27
Cut in diff. VDC 0.5 1.3 10
(refer to 101N2100 Instructions for optional settings)
B 3.59
B1 3.46
B2 0.99
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
September 2013 Manufactured by Secop for Danfoss - DEHC.ED.100.X8.22 / 520N1504 1/2

Capacity (ASHRAE LBP) 12V DC, static cooling BTU/h
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2,000 41 48 78 115 133 162 218 294 325 366 450
2,500 32 57 67 107 154 175 210 278 370 409 461 569
3,000 52 80 92 138 192 216 257 337 447 493 556 685
3,500 51 89 106 164 229 258 306 400 528 582 656 809
4,000 67 105 122 185 260 295 352 462 611 673 757 928
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2,000 10 12 19 28 32 39 52 70 77 87 107
2,500 9 16 19 31 45 51 61 80 105 116 130 159
3,000 14 22 26 39 55 62 74 97 127 140 157 192
3,500 11 24 30 48 68 76 90 116 149 163 181 219
4,000 21 32 36 54 75 85 100 130 170 186 209 253
Power consumption 12V DC, static cooling watt
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2,000 14 15 19 24 26 29 35 40 41 43 44
2,500 19 21 22 25 29 31 34 38 42 43 44 45
3,000 22 24 26 30 36 38 41 46 51 52 53 54
3,500 25 29 31 37 44 46 50 55 60 62 63 65
4,000 31 36 38 45 51 53 57 63 69 71 74 79
Current consumption
(for 24V applications the following must be halfed) A
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2,000 1.31 1.39 1.65 1.90 2.00 2.15 2.41 2.71 2.82 2.96 3.23
2,500 1.51 1.62 1.68 1.95 2.28 2.42 2.63 2.96 3.25 3.33 3.40 3.45
3,000 1.78 1.97 2.06 2.40 2.76 2.91 3.14 3.49 3.82 3.92 4.03 4.17
3,500 1.95 2.25 2.38 2.85 3.32 3.51 3.78 4.20 4.58 4.69 4.81 4.95
4,000 3.17 3.24 3.29 3.56 3.93 4.11 4.38 4.86 5.37 5.55 5.75 6.05
EER (ASHRAE LBP) 12V DC, static cooling BTU/h
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2.000 2.88 3.19 4.06 4.78 5.06 5.49 6.29 7.39 7.88 8.58 10.17
2.500 1.88 2.95 3.33 4.32 5.09 5.38 5.83 6.66 7.79 8.29 9.00 10.57
3.000 2.73 3.55 3.82 4.54 5.16 5.42 5.84 6.68 7.89 8.43 9.19 10.90
3.500 2.09 3.14 3.49 4.42 5.18 5.49 5.96 6.84 8.01 8.50 9.18 10.60
4.000 2.36 3.09 3.36 4.19 5.00 5.34 5.87 6.83 8.03 8.51 9.15 10.40
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °F -20 -13 -10 0 10 14 20 30 41 45 50 59
2.000 0.69 0.77 0.97 1.14 1.21 1.31 1.50 1.76 1.88 2.04 2.42
2.500 0.45 0.77 0.89 1.23 1.52 1.62 1.79 2.09 2.50 2.68 2.94 3.53
3.000 0.62 0.90 1.00 1.29 1.54 1.64 1.80 2.10 2.52 2.70 2.96 3.55
3.500 0.46 0.83 0.96 1.29 1.56 1.66 1.81 2.10 2.48 2.64 2.87 3.35
4.000 0.67 0.88 0.96 1.21 1.48 1.58 1.76 2.07 2.46 2.61 2.82 3.22
Operational errors (TOOL4COOL® or LED ashes)
Error code
or LED
ashes
6
5
4
3
2
1
Can be read out in the software TOOL4COOL®
Thermostat failure
(If the NTC thermistor is short-circuit or has no connection,
the electronic unit will enter manual mode).
Thermal cut-out of electronic unit
(If the refrigeration system has been too hea vi ly loaded,
or if the ambient tem pe ra ture is high, the electronic unit
will run too hot).
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the
motor cannot maintain minimum speed at approximately
1,850 rpm).
Motor start error
(The rotor is blocked or the differential pressure in the
refrigeration system is too high (>5 bar)).
Fan over-current cut-out
(The fan loads the electronic unit with more than
0.65A
).
peak
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
Wire Dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
[mm
] [Gauge] [m] [ft.] [m] [ft.]
2.5 12 2.5 8 5 16
4 12 4 13 8 26
6 10 6 20 12 39
10 8 10 33 20 66
*Length between battery and electronic unit
Accessories for BD1.4F-VSD-HD Code number
Bolt joint for one compressor Ø: 16 m m 118-1917
Bolt joint in quantities Ø:16 mm 118-1918
Snap-on in quantities Ø:16 m m 118-1919
Terminal cover for electronic unit 105N9120
Automoblie fuse
DIN 7258
Main switch
Test conditions EN 12900
Condensing temperature 131°F 130°F
Ambient temperature 90°F 90°F
Suction gas temperature 90°F 90°F
Liquid temperature no subcooling 90°F
12V: 15A
24V: 15A
min. 20A
CECOMAF
Not
deliverable
from Secop
ASHRAE
LBP
refer to 101N2100 Instructions for details
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.100.X8.22 / 520N1504 September 2013