Danfoss BD1.4F-VSD-HD Data sheet

Danfoss BD1.4F-VSD-HD Data sheet

BD1.4F-VSD-HD

Heavy Duty

Direct Current Compressor

R134a, 12-24V DC

General

Code number (without electronic units)

 

109Z0251

Electronic unit - Variable Speed

 

101N2100, 30 pcs: 101N2101

Approvals

 

Compressors on pallet

 

180

Application

 

 

Application

 

LBP/MBP/HBP

Evaporating temperature

°F

-20 to 59

Voltage range

VDC

9.6 - 17 / 19 - 34

Max. condensing temperature continuous (short)

°F

140 (158)

Max. winding temperature continuous (short)

°F

257 (275)

Cooling requirements

Application

 

LBP

 

MBP

 

HBP

32°C

 

S

 

S

 

S

38°C

 

S

 

S

 

S

43°C

 

S

 

S

 

S

Remarks on application:

 

 

 

 

 

 

HD (Heavy Duty) version of the BD1.4F-VSD which can handle extreme vibrations.

For more info please contact: mobile@secop.com.

 

 

 

 

 

Motor

 

 

 

 

 

 

Motor type

 

permanet magnet, brushless DC

Speed

 

 

variable speed

 

Resistance, all 3 windings (25°C)

mΩ

 

210

 

 

Design

 

 

 

 

 

 

Displacement

cu.in.

 

0.086

 

 

Oil quantity (type)

fl.oz.

 

2.64 (polyolester)

 

Maximum refrigerant charge

oz.

 

5.29

 

 

Free gas volume in compressor

fl.oz.

 

17.60

 

 

Weight - Compressor/Electronic unit

lbs.

 

4.63/0.24

 

 

Standard battery protection settings (refer to 101N2100 Instructions for optional settings)

Voltage (0.1 steps)

 

 

Min. value

Default

Max. value

12V

± 0.3V DC,

Cut out

VDC

 

9.6

10.4

17

all values

Cut in diff.

VDC

 

0.5

1.3

10

 

 

24V

± 0.3V DC,

Cut out

VDC

 

19

21.3

27

all values

Cut in diff.

VDC

 

0.5

1.3

10

 

 

Dimensions

 

 

 

 

 

 

Height

 

 

inch

A

 

3.79

 

 

 

 

 

B

 

3.59

 

 

 

 

 

B1

 

3.46

 

 

 

 

 

B2

 

0.99

 

Suction connector

location/I.D. inch | angle

C

0.252-0259 | 25°

 

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location/I.D. inch | angle

D

0.252-0259 | 25°

 

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. inch | angle

E

0.202-0.205 | 0°

 

 

material | comment

 

Cu-plated steel | Al cap

Remarks: inch connectors

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

September 2013

Manufactured by Secop for Danfoss - DEHC.ED.100.X8.22 / 520N1504

1/2

Capacity (ASHRAE LBP)

 

 

 

 

 

 

 

 

 

12V DC, static cooling

 

 

 

 

 

BTU/h

Operational errors (TOOL4COOL® or LED flashes)

rpm \ °F

-20

-13

-10

0

 

10

 

 

14

 

20

 

30

 

41

45

 

 

50

 

 

 

59

 

 

 

 

Error code

 

 

 

 

Error type

 

 

 

 

 

2,000

 

41

48

78

 

115

 

 

133

162

 

218

294

325

366

 

 

450

 

 

 

 

or LED

Can be read out in the software TOOL4COOL®

 

 

 

 

 

 

 

 

 

 

 

flashes

2,500

32

57

67

107

 

154

 

 

175

210

 

278

370

409

461

 

 

569

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Thermostat failure

 

 

 

 

 

 

 

 

 

 

 

3,000

52

80

92

138

 

192

 

 

216

257

 

337

447

493

556

 

 

685

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(If the NTC thermistor is short-circuit or has no connection,

3,500

51

89

106

164

 

229

 

 

258

306

 

400

528

582

656

 

 

809

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the electronic unit will enter manual mode).

4,000

67

105

122

185

 

260

 

 

295

352

 

462

611

673

757

 

 

928

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Thermal cut-out of electronic unit

 

 

Capacity

(EN

12900 Household/CECOMAF)

 

12V DC, static cooling

 

 

 

 

 

 

watt

 

 

 

(If the refrigeration system has been too hea­vily­ loaded,

 

 

 

 

 

 

 

 

 

 

or if the ambient tempe­ra­ture­ is high, the electronic unit

rpm \ °F

-20

-13

-10

0

 

10

 

 

14

 

20

 

30

 

41

45

 

 

50

 

 

59

 

 

 

 

 

 

 

will run too hot).

 

 

 

 

 

 

 

 

 

 

 

2,000

 

10

12

19

 

28

 

 

32

 

39

 

52

 

70

77

 

 

87

 

 

107

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

Minimum motor speed error

 

 

 

 

 

2,500

9

16

19

31

 

45

 

 

51

 

61

 

80

 

105

116

 

130

 

 

159

 

 

 

 

 

 

 

(If the refrigeration system is too heavily loaded, the

3,000

14

22

26

39

 

55

 

 

62

 

74

 

97

 

127

140

157

 

 

192

 

 

 

 

 

 

 

motor cannot maintain minimum speed at approximately

3,500

11

24

30

48

 

68

 

 

76

 

90

 

116

149

163

181

 

 

219

 

 

 

 

 

 

 

1,850 rpm).

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Motor start error

 

 

 

 

 

 

 

 

 

 

 

4,000

21

32

36

54

 

75

 

 

85

 

100

130

170

186

209

 

 

253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

12V DC, static cooling

 

 

 

 

 

 

watt

 

 

 

(The rotor is blocked or the differential pressure in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

refrigeration system is too high (>5 bar)).

 

 

rpm \ °F

-20

-13

-10

0

 

10

 

 

14

 

20

 

30

 

41

45

 

50

 

 

59

 

 

 

 

2

 

Fan over-current cut-out

 

 

 

 

 

2,000

 

14

15

19

 

24

 

 

26

 

29

 

35

 

40

41

 

43

 

 

44

 

 

 

 

 

 

 

(The fan loads the electronic unit with more than

2,500

19

21

22

25

 

29

 

 

31

 

34

 

38

 

42

43

 

44

 

 

45

 

 

 

 

 

 

 

0.65Apeak).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Battery protection cut-out

 

 

 

 

 

3,000

22

24

26

30

 

36

 

 

38

 

41

 

46

 

51

52

 

53

 

 

54

 

 

 

 

 

 

 

 

 

 

3,500

25

29

31

37

 

44

 

 

46

 

50

 

55

 

60

62

 

63

 

 

65

 

 

 

 

 

 

 

(The voltage is outside the cut-out setting).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4,000

31

36

38

45

 

51

 

 

53

 

57

 

63

 

69

71

 

74

 

 

79

 

 

 

 

Wire Dimensions DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

consumption (for 24V applications the following must be halfed)

 

 

 

 

 

 

 

 

A

 

 

Size

 

Max. length*

 

 

Max. length*

rpm \ °F

-20

-13

-10

0

 

10

 

 

14

 

20

 

30

 

41

45

 

 

50

 

 

 

59

 

 

 

 

Cross

AWG

 

12V operation

 

 

24V operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,000

 

1.31

1.39

1.65

 

1.90

 

2.00

2.15

2.41

2.71

2.82

2.96

 

3.23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[mm2]

[Gauge]

 

[m]

 

[ft.]

 

 

[m]

 

[ft.]

2,500

1.51

1.62

1.68

1.95

 

2.28

 

2.42

2.63

2.96

3.25

3.33

3.40

 

3.45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

 

12

 

2.5

8

 

 

 

5

 

16

3,000

1.78

1.97

2.06

2.40

 

2.76

 

2.91

3.14

3.49

3.82

3.92

4.03

 

4.17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

12

 

4

13

 

 

 

8

 

26

3,500

1.95

2.25

2.38

2.85

 

3.32

 

3.51

3.78

4.20

4.58

4.69

4.81

 

4.95

 

 

6

 

10

 

6

20

 

 

 

12

 

39

4,000

3.17

3.24

3.29

3.56

 

3.93

 

4.11

4.38

4.86

5.37

5.55

5.75

 

6.05

 

 

10

 

8

 

10

33

 

 

 

20

 

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Length between battery and electronic unit

EER (ASHRAE LBP)

 

 

 

 

 

 

 

 

 

 

 

 

 

12V DC, static cooling

 

 

 

 

 

 

BTU/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rpm \ °F

-20

-13

-10

0

 

10

 

 

14

 

20

 

30

 

41

45

 

 

50

 

 

59

 

 

 

 

Accessories for BD1.4F-VSD-HD

 

Code number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bolt joint for one compressor

 

Ø:16 mm

 

 

 

118-1917

2.000

 

2.88

3.19

4.06

 

4.78

 

5.06

5.49

6.29

7.39

7.88

8.58

 

10.17

 

 

 

 

 

 

 

 

Bolt joint in quantities

 

 

Ø:16 mm

 

 

 

118-1918

2.500

1.88

2.95

3.33

4.32

 

5.09

 

5.38

5.83

6.66

7.79

8.29

9.00

 

10.57

 

 

 

 

 

 

 

 

Snap-on in quantities

 

 

Ø:16 mm

 

 

 

118-1919

3.000

2.73

3.55

3.82

4.54

 

5.16

 

5.42

5.84

6.68

7.89

8.43

9.19

 

10.90

 

 

 

 

 

 

 

 

Terminal cover for electronic unit

 

 

 

105N9120

3.500

2.09

3.14

3.49

4.42

 

5.18

 

5.49

5.96

6.84

8.01

8.50

9.18

 

10.60

 

 

 

 

 

 

Automoblie fuse

 

 

 

12V: 15A

 

 

 

 

Not

4.000

2.36

3.09

3.36

4.19

 

5.00

 

5.34

5.87

6.83

8.03

8.51

9.15

 

10.40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIN 7258

 

 

 

 

 

 

24V: 15A

 

 

 

deliverable

COP (EN 12900 Household/CECOMAF)

 

 

 

12V DC, static cooling

 

 

 

 

 

 

W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main switch

 

 

 

min. 20A

 

 

from Secop

rpm \ °F

-20

-13

-10

0

 

10

 

 

14

 

20

 

30

 

41

45

 

 

50

 

 

 

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.000

 

0.69

0.77

0.97

 

1.14

 

1.21

1.31

1.50

1.76

1.88

2.04

 

2.42

 

 

 

 

Test conditions

 

EN 12900

 

 

 

ASHRAE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CECOMAF

 

 

LBP

2.500

0.45

0.77

0.89

1.23

 

1.52

 

1.62

1.79

2.09

2.50

2.68

2.94

 

3.53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensing temperature

 

 

131°F

 

 

 

130°F

3.000

0.62

0.90

1.00

1.29

 

1.54

 

1.64

1.80

2.10

2.52

2.70

2.96

 

3.55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature

 

 

 

90°F

 

 

 

 

90°F

3.500

0.46

0.83

0.96

1.29

 

1.56

 

1.66

1.81

2.10

2.48

2.64

2.87

 

3.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction gas temperature

 

 

90°F

 

 

 

 

90°F

4.000

0.67

0.88

0.96

1.21

 

1.48

 

1.58

1.76

2.07

2.46

2.61

2.82

 

3.22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid temperature

 

no subcooling

 

 

90°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

refer to 101N2100 Instructions for details

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.100.X8.22 / 520N1504

September 2013

Loading...