BD1.4F-VSD
Direct Current Compressor
R134a
12-24V
General
Code number (without electronic unit) 109Z0200
Electronic unit 101N2100, 30 pcs: 101N2101
Approvals –
Compressors on pallet 180
Application
Application LBP/MBP
Evaporating temperature °C -30 to 0
Voltage range VDC 12 (9.6 - 17) / 24 (19 - 34)
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S S –
38°C S S –
43°C S S –
Remarks on application:
Motor
Motor type permanet magnet, brushless DC
Speed rpm variable speed
Resistance, all 3 windings (25°C) mΩ 50
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 2.1/0.17
°C 60 (70)
3
3
3
1.41
75 (polyolester)
500
S = Static cooling normally suffi cient
O = Oil cooling
= Fan cooling 1.5 m/s
F
1
(compressor compartment temperature
equal to ambient temperature)
F
= Fan cooling 3.0 m/s necessary
2
SG = Suction gas cooling normally suffi cent
– = not applicable in this area
Standard battery protection settings
Voltage (0.1 steps) Min. value Default Max. value
± 0.3V DC,
12V
all values
± 0.3V DC,
24V
all values
Dimensions
Height mm A 96.25
Suction connector location/I.D. mm | angle C 6.2 | 15°
Process connector location/I.D. mm | angle D 6.2 | 25°
Discharge connector location/I.D. mm | angle E 5.0 | 15°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks
July 2012 DEHC.ED.100.W3.02 1/2
Cut out VDC 9.6 10.4 17
Cut in diff. VDC 0.5 1.3 10
Cut out VDC 19 21.3 27
Cut in diff. VDC 0.5 1.3 10
(refer to 101N2100 Instructions for optional settings)
B 91.25
B1 81.00
B2 38.50
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
2,000 9.3 11.0 15.0 22.4 31.4 38.2 42.0 54.3
2,500 6.9 12.7 15.1 20.4 29.9 41.3 49.9 54.6 69.8
3,000 8.7 16.1 19.2 25.7 37.4 51.2 61.5 67.1 85.2
3,500 10.4 19.5 23.1 31.0 44.8 61.0 73.0 79.6 100.6
4,000 12.1 22.8 27.1 36.2 52.2 70.8 84.5 92.1 115.9
Capacity (ASHRAE LBP) 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
2,000 11.6 13.8 18.7 27.9 39.1 47.6 52.4 67.7
2,500 8.6 15.8 18.8 25.3 37.1 51.3 61.9 67.8 86.8
3,000 11.0 20.2 23.9 32.0 46.5 63.6 76.4 83.5 106.0
3,500 13.1 24.3 28.8 38.5 55.6 75.7 90.6 98.8 124.9
4,000 15.4 28.6 33.9 45.1 64.9 88.0 105.0 114.3 144.0
Power consumption 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
2,000 15.7 16.6 18.5 21.7 25.3 28.0 29.4 33.8
2,500 16.2 19.7 21.0 23.6 27.7 32.2 35.2 36.9 41.9
3,000 19.3 24.1 25.7 29.0 34.1 39.3 42.9 44.7 50.3
3,500 22.8 28.7 30.8 34.7 40.8 46.8 50.8 52.9 59.0
4,000 26.6 33.8 36.2 40.8 47.8 54.7 59.1 61.4 68.1
Current consumption
(for 24V applications the following must be halfed) A
rpm \ °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
2,000 1.25 1.33 1.48 1.74 2.02 2.22 2.32 2.65
2,500 1.25 1.53 1.63 1.83 2.15 2.48 2.72 2.84 3.22
3,000 1.49 1.84 1.96 2.20 2.59 2.98 3.25 3.40 3.82
3,500 1.77 2.19 2.34 2.63 3.07 3.53 3.84 4.00 4.47
4,000 2.08 2.58 2.75 3.08 3.59 4.10 4.45 4.63 5.16
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
2,000 0.59 0.66 0.81 1.03 1.24 1.37 1.43 1.60
2,500 0.43 0.64 0.72 0.86 1.08 1.29 1.42 1.48 1.67
3,000 0.45 0.67 0.74 0.89 1.10 1.30 1.43 1.50 1.69
3,500 0.46 0.68 0.75 0.89 1.10 1.30 1.44 1.51 1.70
4,000 0.45 0.68 0.75 0.89 1.09 1.30 1.43 1.50 1.70
COP (ASHRAE LBP) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
2,000 0.74 0.83 1.01 1.29 1.55 1.71 1.79 2.01
2,500 0.54 0.80 0.89 1.07 1.34 1.60 1.76 1.84 2.08
3,000 0.57 0.84 0.93 1.11 1.37 1.62 1.79 1.87 2.11
3,500 0.58 0.85 0.94 1.11 1.36 1.62 1.79 1.87 2.12
4,000 0.58 0.85 0.94 1.11 1.36 1.61 1.78 1.87 2.12
Operational errors (TOOL4COOL® or LED fl ashes)
Error code
or LED
fl ashes
6
5
4
3
2
1
Can be read out in the software TOOL4COOL®
Thermostat failure
(If the NTC thermistor is short-circuit or has no connection,
the electronic unit will enter manual mode).
Thermal cut-out of electronic unit
(If the refrigeration system has been too hea vi ly loaded,
or if the ambient tem pe ra ture is high, the electronic unit
will run too hot).
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the
motor cannot maintain minimum speed at approximately
1,850 rpm).
Motor start error
(The rotor is blocked or the differential pressure in the
refrigeration system is too high (>5 bar)).
Fan over-current cut-out
(The fan loads the electronic unit with more than
0.65A
).
peak
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
Wire Dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
[mm2] [Gauge] [m] [ft.] [m] [ft.]
2.5 12 2.5 8 5 16
412413826
6 10 6 20 12 39
10 8 10332066
*Length between battery and electronic unit
Accessories for BD1.4F-VSD Code number
Bolt joint for one compressor Ø:16 mm 118-1917
Bolt joint in quantities Ø:16 mm 118-1918
Snap-on in quantities Ø:16 mm 118-1919
Terminal cover for electronic unit 105N9120
Automoblie fuse
DIN 7258
Main switch
Test conditions EN 12900
Condensing temperature 55°C 54.4°C
Ambient temperature 32°C 32°C
Suction gas temperature 32°C 32°C
Liquid temperature no subcooling 32°C
12V: 15A
24V: 15A
min. 20A
CECOMAF
Not
deliverable
from Secop
ASHRAE
LBP
refer to 101N2100 Instructions for details
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifi cations already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Designed by Secop for Danfoss - DEHC.ED.100.W3.02 July 2012