BD1.4F-FSD
Direct Current Compressor
R134a, 12-24V DC
& 100-240V AC 50/60Hz
General
Code number (without electronic unit) |
|
|
|
109Z0305 |
|
|
Electronic unit - Fixed Speed |
|
101N2600, 30 pcs: 101N2601 |
||||
Electronic unit - Fixed Speed w. AC/DC converter |
101N5200, 30 pcs: 101N5201 |
|||||
Approvals |
|
VDE, UL, CCC, C-Tick |
||||
Compressors on pallet |
|
|
180 |
|
|
|
Application |
|
|
|
|
|
|
Application |
|
|
|
LBP/MBP |
|
|
Evaporating temperature |
°C |
|
|
-30 to 0 |
|
|
Voltage range DC |
VDC |
|
9.6 - 17 / 19 - 34 |
|
||
Voltage range AC |
V/Hz |
|
100 - 240 / 50 - 60 |
|||
Max. condensing temperature continuous (short) |
°C |
|
60 (70) |
|
|
|
Max. winding temperature continuous (short) |
°C |
|
125 (135) |
|
|
|
Cooling requirements |
|
|
|
|
|
|
Application |
|
LBP |
|
MBP |
|
HBP |
32°C |
|
S |
|
S |
|
– |
38°C |
|
S |
|
S |
|
– |
43°C |
|
S |
|
S |
|
– |
Remarks on application: |
|
|
|
|
|
|
Motor |
|
|
|
|
|
|
Motor type |
|
permanent magnet, brushless DC |
||||
Speed |
rpm |
|
3000 |
|
|
|
Resistance, all 3 windings (25°C) |
mΩ |
|
210 |
|
|
|
Design |
|
|
|
|
|
|
Displacement |
cm3 |
|
1.41 |
|
|
|
Oil quantity (type) |
cm3 |
|
75 (polyolester) |
|
||
Maximum refrigerant charge |
g |
|
150 |
|
|
|
Free gas volume in compressor |
cm3 |
|
500 |
|
|
|
Weight - Compressor/Electronic unit |
kg |
2.1 / 0.11 (DC) / 0.29 (AC/DC) |
Standard battery protection settings (refer to 101N2600/5200 Instructions for optional settings)
Voltage (0.1 steps) |
|
|
Min. value |
Default |
Max. value |
||
12V |
± 0.3V DC, |
Cut out |
VDC |
|
9.6 |
10.4 |
17 |
all values |
Cut in diff. |
VDC |
|
0.5 |
1.3 |
10 |
|
|
|
||||||
24V |
± 0.3V DC, |
Cut out |
VDC |
|
19 |
21.3 |
27 |
all values |
Cut in diff. |
VDC |
|
0.5 |
1.3 |
10 |
|
|
|
||||||
Dimensions |
|
|
|
|
|
|
|
Height |
|
|
mm |
A |
|
96.25 |
|
|
|
|
|
B |
|
91.25 |
|
|
|
|
|
B1 |
|
88.00 |
|
|
|
|
|
B2 |
|
25.20 |
|
Suction connector |
location/I.D. mm | angle |
C |
|
6.2 | 25° |
|
||
|
|
material | comment |
|
Cu-plated steel | Al cap |
|||
Process connector |
location/I.D. mm | angle |
D |
|
6.2 | 25° |
|
||
|
|
material | comment |
|
Cu-plated steel | Al cap |
|||
Discharge connector |
location/I.D. mm | angle |
E |
|
5.0 | 0° |
|
||
|
|
material | comment |
|
Cu-plated steel | Al cap |
|||
Connector tolerance |
|
I.D. mm |
|
±0.09, on 5.0 +0.12/+0.20 |
S = Static cooling normally sufficient
O= Oil cooling
F1 |
= Fan cooling 1.5 m/s |
|
(compressor compartment temperature |
|
equal to ambient temperature) |
F2 |
= Fan cooling 3.0 m/s necessary |
SG |
= Suction gas cooling normally sufficent |
–= not applicable in this area
September 2013 |
Manufactured by Secop for Danfoss - DEHC.ED.100.X4.02 / 520N1500 |
1/2 |
EN 12900 Household (CECOMAF) |
|
|
|
|
|
|
|
|
||||
Evap. temp. in °C |
|
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
|
-6.7 |
-5 |
0 |
|
Capacity in W |
|
4.7 |
13.2 |
|
16.4 |
23.3 |
35.2 |
49.4 |
|
60.1 |
66.0 |
85.4 |
Power cons. in W |
|
15.7 |
22.6 |
|
24.8 |
28.8 |
34.5 |
39.6 |
|
42.8 |
44.4 |
48.7 |
Current cons. in A |
|
1.30 |
1.73 |
|
1.88 |
2.16 |
2.57 |
2.98 |
|
3.24 |
3.37 |
3.76 |
COP in W/W |
|
0.30 |
0.58 |
|
0.66 |
0.81 |
1.02 |
1.25 |
|
1.40 |
1.49 |
1.75 |
EN 12900 Household (CECOMAF) |
|
|
|
|
|
|
|
|
||||
Evap. temp. in °F |
|
-20 |
-13 |
|
-10 |
0 |
10 |
14 |
|
20 |
30 |
32 |
Capacity in W |
|
6.5 |
13.2 |
|
16.4 |
28.3 |
42.8 |
49.4 |
|
60.2 |
80.9 |
85.4 |
Power cons. in W |
|
17.3 |
22.6 |
|
24.7 |
31.4 |
37.4 |
39.6 |
|
42.8 |
47.8 |
48.7 |
Current cons. in A |
|
1.40 |
1.73 |
|
1.88 |
2.34 |
2.80 |
2.98 |
|
3.24 |
3.68 |
3.76 |
COP in W/W |
|
0.38 |
0.58 |
|
0.66 |
0.90 |
1.14 |
1.25 |
|
1.41 |
1.69 |
1.75 |
ASHRAE LBP |
|
|
|
|
|
|
|
|
|
|
|
|
Evap. temp. in °F |
|
-20 |
-13 |
|
-10 |
0 |
10 |
14 |
|
20 |
30 |
32 |
Capacity in BTU/h |
|
29.1 |
57.3 |
|
70.7 |
121.1 |
182.1 |
210 |
|
256 |
343 |
362 |
Power cons. in W |
|
17.5 |
22.8 |
|
24.9 |
31.4 |
37.3 |
39.5 |
|
42.7 |
47.5 |
48.4 |
Current cons. in A |
|
1.41 |
1.75 |
|
1.89 |
2.35 |
2.80 |
2.97 |
|
3.24 |
3.66 |
3.75 |
ERR in BTU/h |
|
1.66 |
2.52 |
|
2.84 |
3.85 |
4.88 |
5.31 |
|
5.99 |
7.22 |
7.48 |
ASHRAE LBP |
|
|
|
|
|
|
|
|
|
|
|
|
Evap. temp. in °C |
|
-30 |
-25 |
-23.3 |
-20 |
-15 |
-10 |
|
-6.7 |
-5 |
0 |
|
Capacity in W |
|
6.4 |
16.8 |
|
20.8 |
29.2 |
44.0 |
61.5 |
|
74.8 |
82.2 |
106 |
Power cons. in W |
|
16.0 |
22.8 |
|
24.9 |
28.9 |
34.5 |
39.5 |
|
42.6 |
44.2 |
48.4 |
Current cons. in A |
|
1.32 |
1.75 |
|
1.89 |
2.16 |
2.57 |
2.97 |
|
3.23 |
3.37 |
3.75 |
COP in W/W |
|
0.40 |
0.74 |
|
0.83 |
1.01 |
1.28 |
1.56 |
|
1.75 |
1.86 |
2.19 |
|
|
|
|
|
|
|||||||
Test conditions |
|
EN 12900/CECOMAF |
|
ASHRAE LBP |
|
|||||||
Condensing temperature |
|
|
55°C |
|
|
|
54.4°C |
|
||||
Ambient temperature |
|
|
|
32°C |
|
|
|
32°C |
|
|||
Suction gas temperature |
|
|
32°C |
|
|
|
32°C |
|
||||
Liquid temperature |
|
|
no subcooling |
|
|
|
32°C |
|
Operational errors (TOOL4COOL® or LED flashes)
Error code |
Error type |
or LED |
Can be read out in the software TOOL4COOL® |
flashes |
|
6 |
Thermostat failure |
|
(If the NTC thermistor is short-circuit or has no connection, |
|
the electronic unit will enter manual mode). |
5 |
Thermal cut-out of electronic unit |
|
(If the refrigeration system has been too heavily loaded, |
|
or if the ambient temperature is high, the electronic unit |
|
will run too hot). |
4 |
Minimum motor speed error |
|
(If the refrigeration system is too heavily loaded, the |
|
motor cannot maintain minimum speed at approximately |
|
1,850 rpm). |
3 |
Motor start error |
|
(The rotor is blocked or the differential pressure in the |
|
refrigeration system is too high (>5 bar)). |
2 |
Fan over-current cut-out |
|
(The fan loads the electronic unit with more than |
|
0.65Apeak). |
1 |
Battery protection cut-out |
|
(The voltage is outside the cut-out setting). |
Wire Dimensions DC
|
Size |
Max. length* |
Max. length* |
|||
Cross |
|
AWG |
12V operation |
24V operation |
||
section |
|
|
|
|
|
|
[mm2] |
|
[Gauge] |
[m] |
[ft.] |
[m] |
[ft.] |
2.5 |
|
12 |
2.5 |
8 |
5 |
16 |
4 |
|
12 |
4 |
13 |
8 |
26 |
6 |
|
10 |
6 |
20 |
12 |
39 |
10 |
|
8 |
10 |
33 |
20 |
66 |
*Length between battery and electronic unit
Accessories for BD1.4F-FSD |
|
Code number |
Bolt joint for one compressor |
Ø:16 mm |
118-1917 |
Bolt joint in quantities |
Ø:16 mm |
118-1918 |
Snap-on in quantities |
Ø:16 mm |
118-1919 |
Terminal cover for electronic unit |
|
105N9120 |
Automoblie fuse |
12V: 15A |
Not |
DIN 7258 |
24V: 15A |
deliverable |
Main switch |
min. 20A |
from Secop |
101N2600 |
101N5200 |
refer to 101N2600 and 101N5200 Instructions for details |
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 |
Manufactured by Secop for Danfoss - DEHC.ED.100.X4.02 / 520N1500 |
September 2013 |