Danfoss BD1.4F-FSD Data sheet

BD1.4F-FSD

Direct Current Compressor

R134a, 12-24V DC

& 100-240V AC 50/60Hz

General

Code number (without electronic unit)

 

 

 

109Z0305

 

Electronic unit - Fixed Speed

 

101N2600, 30 pcs: 101N2601

Electronic unit - Fixed Speed w. AC/DC converter

101N5200, 30 pcs: 101N5201

Approvals

 

VDE, UL, CCC, C-Tick

Compressors on pallet

 

 

180

 

 

Application

 

 

 

 

 

 

Application

 

 

 

LBP/MBP

 

Evaporating temperature

°C

 

 

-30 to 0

 

Voltage range DC

VDC

 

9.6 - 17 / 19 - 34

 

Voltage range AC

V/Hz

 

100 - 240 / 50 - 60

Max. condensing temperature continuous (short)

°C

 

60 (70)

 

 

Max. winding temperature continuous (short)

°C

 

125 (135)

 

 

Cooling requirements

 

 

 

 

 

 

Application

 

LBP

 

MBP

 

HBP

32°C

 

S

 

S

 

38°C

 

S

 

S

 

43°C

 

S

 

S

 

Remarks on application:

 

 

 

 

 

 

Motor

 

 

 

 

 

 

Motor type

 

permanent magnet, brushless DC

Speed

rpm

 

3000

 

 

Resistance, all 3 windings (25°C)

mΩ

 

210

 

 

Design

 

 

 

 

 

 

Displacement

cm3

 

1.41

 

 

Oil quantity (type)

cm3

 

75 (polyolester)

 

Maximum refrigerant charge

g

 

150

 

 

Free gas volume in compressor

cm3

 

500

 

 

Weight - Compressor/Electronic unit

kg

2.1 / 0.11 (DC) / 0.29 (AC/DC)

Standard battery protection settings (refer to 101N2600/5200 Instructions for optional settings)

Voltage (0.1 steps)

 

 

Min. value

Default

Max. value

12V

± 0.3V DC,

Cut out

VDC

 

9.6

10.4

17

all values

Cut in diff.

VDC

 

0.5

1.3

10

 

 

24V

± 0.3V DC,

Cut out

VDC

 

19

21.3

27

all values

Cut in diff.

VDC

 

0.5

1.3

10

 

 

Dimensions

 

 

 

 

 

 

Height

 

 

mm

A

 

96.25

 

 

 

 

 

B

 

91.25

 

 

 

 

 

B1

 

88.00

 

 

 

 

 

B2

 

25.20

 

Suction connector

location/I.D. mm | angle

C

 

6.2 | 25°

 

 

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location/I.D. mm | angle

D

 

6.2 | 25°

 

 

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location/I.D. mm | angle

E

 

5.0 | 0°

 

 

 

material | comment

 

Cu-plated steel | Al cap

Connector tolerance

 

I.D. mm

 

±0.09, on 5.0 +0.12/+0.20

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

September 2013

Manufactured by Secop for Danfoss - DEHC.ED.100.X4.02 / 520N1500

1/2

Danfoss BD1.4F-FSD Data sheet

EN 12900 Household (CECOMAF)

 

 

 

 

 

 

 

 

Evap. temp. in °C

 

-30

-25

-23.3

-20

-15

-10

 

-6.7

-5

0

Capacity in W

 

4.7

13.2

 

16.4

23.3

35.2

49.4

 

60.1

66.0

85.4

Power cons. in W

 

15.7

22.6

 

24.8

28.8

34.5

39.6

 

42.8

44.4

48.7

Current cons. in A

 

1.30

1.73

 

1.88

2.16

2.57

2.98

 

3.24

3.37

3.76

COP in W/W

 

0.30

0.58

 

0.66

0.81

1.02

1.25

 

1.40

1.49

1.75

EN 12900 Household (CECOMAF)

 

 

 

 

 

 

 

 

Evap. temp. in °F

 

-20

-13

 

-10

0

10

14

 

20

30

32

Capacity in W

 

6.5

13.2

 

16.4

28.3

42.8

49.4

 

60.2

80.9

85.4

Power cons. in W

 

17.3

22.6

 

24.7

31.4

37.4

39.6

 

42.8

47.8

48.7

Current cons. in A

 

1.40

1.73

 

1.88

2.34

2.80

2.98

 

3.24

3.68

3.76

COP in W/W

 

0.38

0.58

 

0.66

0.90

1.14

1.25

 

1.41

1.69

1.75

ASHRAE LBP

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

 

-20

-13

 

-10

0

10

14

 

20

30

32

Capacity in BTU/h

 

29.1

57.3

 

70.7

121.1

182.1

210

 

256

343

362

Power cons. in W

 

17.5

22.8

 

24.9

31.4

37.3

39.5

 

42.7

47.5

48.4

Current cons. in A

 

1.41

1.75

 

1.89

2.35

2.80

2.97

 

3.24

3.66

3.75

ERR in BTU/h

 

1.66

2.52

 

2.84

3.85

4.88

5.31

 

5.99

7.22

7.48

ASHRAE LBP

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

 

-30

-25

-23.3

-20

-15

-10

 

-6.7

-5

0

Capacity in W

 

6.4

16.8

 

20.8

29.2

44.0

61.5

 

74.8

82.2

106

Power cons. in W

 

16.0

22.8

 

24.9

28.9

34.5

39.5

 

42.6

44.2

48.4

Current cons. in A

 

1.32

1.75

 

1.89

2.16

2.57

2.97

 

3.23

3.37

3.75

COP in W/W

 

0.40

0.74

 

0.83

1.01

1.28

1.56

 

1.75

1.86

2.19

 

 

 

 

 

 

Test conditions

 

EN 12900/CECOMAF

 

ASHRAE LBP

 

Condensing temperature

 

 

55°C

 

 

 

54.4°C

 

Ambient temperature

 

 

 

32°C

 

 

 

32°C

 

Suction gas temperature

 

 

32°C

 

 

 

32°C

 

Liquid temperature

 

 

no subcooling

 

 

 

32°C

 

Operational errors (TOOL4COOL® or LED flashes)

Error code

Error type

or LED

Can be read out in the software TOOL4COOL®

flashes

6

Thermostat failure

 

(If the NTC thermistor is short-circuit or has no connection,

 

the electronic unit will enter manual mode).

5

Thermal cut-out of electronic unit

 

(If the refrigeration system has been too hea­vily­ loaded,

 

or if the ambient tempe­ra­ture­ is high, the electronic unit

 

will run too hot).

4

Minimum motor speed error

 

(If the refrigeration system is too heavily loaded, the

 

motor cannot maintain minimum speed at approximately

 

1,850 rpm).

3

Motor start error

 

(The rotor is blocked or the differential pressure in the

 

refrigeration system is too high (>5 bar)).

2

Fan over-current cut-out

 

(The fan loads the electronic unit with more than

 

0.65Apeak).

1

Battery protection cut-out

 

(The voltage is outside the cut-out setting).

Wire Dimensions DC

 

Size

Max. length*

Max. length*

Cross

 

AWG

12V operation

24V operation

section

 

 

 

 

 

[mm2]

 

[Gauge]

[m]

[ft.]

[m]

[ft.]

2.5

 

12

2.5

8

5

16

4

 

12

4

13

8

26

6

 

10

6

20

12

39

10

 

8

10

33

20

66

*Length between battery and electronic unit

Accessories for BD1.4F-FSD

 

Code number

Bolt joint for one compressor

Ø:16 mm

118-1917

Bolt joint in quantities

Ø:16 mm

118-1918

Snap-on in quantities

Ø:16 mm

118-1919

Terminal cover for electronic unit

 

105N9120

Automoblie fuse

12V: 15A

Not

DIN 7258

24V: 15A

deliverable

Main switch

min. 20A

from Secop

101N2600

101N5200

refer to 101N2600 and 101N5200 Instructions for details

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.100.X4.02 / 520N1500

September 2013