BD1.4F-FSD
Direct Current Compressor
R134a, 12-24V DC
& 100-240V AC 50/60Hz
General
Code number (without electronic unit) 109Z0305
Electronic unit - Fixed Speed 101N2600, 30 pcs: 101N2601
Electronic unit - Fixed Speed w. AC/DC converter 101N5200, 30 pcs: 101N5201
Approvals VDE, UL, CCC, C-Tick
Compressors on pallet 180
Application
Application LBP/MBP
Evaporating temperature °C -30 to 0
Voltage range DC VDC 9.6 - 17 / 19 - 34
Voltage range AC V/Hz 100 - 240 / 50 - 60
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S S –
38°C S S –
43°C S S –
Remarks on application:
°C 60 (70)
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
Motor
Motor type permanent magnet, brushless DC
Speed rpm 3000
Resistance, all 3 windings (25°C) mΩ 210
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 2.1 / 0.11 (DC) / 0.29 (AC/DC)
Standard battery protection settings
Voltage (0.1 steps) Min. value Default Max. value
± 0.3V DC,
12V
all values
± 0.3V DC,
24V
all values
Dimensions
Height mm A 96.25
Suction connector location/I.D. mm | angle C 6.2 | 25°
Process connector location/I.D. mm | angle D 6.2 | 25°
Discharge connector location/I.D. mm | angle E 5.0 | 0°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Cut out VDC 9.6 10.4 17
Cut in diff. VDC 0.5 1.3 10
Cut out VDC 19 21.3 27
Cut in diff. VDC 0.5 1.3 10
(refer to 101N2600/5200 Instructions for optional settings)
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
3
3
3
B 91.25
B1 88.00
B2 25.20
75 (polyolester)
1.41
500
September 2013 Manufactured by Secop for Danfoss - DEHC.ED.100.X4.02 / 520N1500 1/2
EN 12900 Household (CECOMAF)
Evap. temp. in °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
Capacity in W 4.7 13.2 16.4 23.3 35.2 49.4 60.1 66.0 85.4
Power cons. in W 15.7 22.6 24.8 28.8 34.5 39.6 42.8 44.4 48.7
Current cons. in A 1.30 1.73 1.88 2.16 2.57 2.98 3.24 3.37 3.76
COP in W/W 0.30 0.58 0.66 0.81 1.02 1.25 1.40 1.49 1.75
EN 12900 Household (CECOMAF)
Evap. temp. in °F -20 -13 -10 0 10 14 20 30 32
Capacity in W 6.5 13.2 16.4 28.3 42.8 49.4 60.2 80.9 85.4
Power cons. in W 17.3 22.6 24.7 31.4 37.4 39.6 42.8 47.8 48.7
Current cons. in A 1.40 1.73 1.88 2.34 2.80 2.98 3.24 3.68 3.76
COP in W/W 0.38 0.58 0.66 0.90 1.14 1.25 1.41 1.69 1.75
ASHRAE LBP
Evap. temp. in °F -20 -13 -10 0 10 14 20 30 32
Capacity in BTU/h 29.1 57.3 70.7 121.1 182.1 210 256 343 362
Power cons. in W 17.5 22.8 24.9 31.4 37.3 39.5 42.7 47.5 48.4
Current cons. in A 1.41 1.75 1.89 2.35 2.80 2.97 3.24 3.66 3.75
ERR in BTU/h 1.66 2.52 2.84 3.85 4.88 5.31 5.99 7.22 7.48
Operational errors (TOOL4COOL® or LED ashes)
Error code
or LED
ashes
6
5
4
3
2
1
Can be read out in the software TOOL4COOL®
Thermostat failure
(If the NTC thermistor is short-circuit or has no connection,
the electronic unit will enter manual mode).
Thermal cut-out of electronic unit
(If the refrigeration system has been too hea vi ly loaded,
or if the ambient tem pe ra ture is high, the electronic unit
will run too hot).
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the
motor cannot maintain minimum speed at approximately
1,850 rpm).
Motor start error
(The rotor is blocked or the differential pressure in the
refrigeration system is too high (>5 bar)).
Fan over-current cut-out
(The fan loads the electronic unit with more than
0.65A
).
peak
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
ASHRAE LBP
Evap. temp. in °C -30 -25 -23.3 -20 -15 -10 -6.7 -5 0
Capacity in W 6.4 16.8 20.8 29.2 44.0 61.5 74.8 82.2 106
Power cons. in W 16.0 22.8 24.9 28.9 34.5 39.5 42.6 44.2 48.4
Current cons. in A 1.32 1.75 1.89 2.16 2.57 2.97 3.23 3.37 3.75
COP in W/W 0.40 0.74 0.83 1.01 1.28 1.56 1.75 1.86 2.19
Test conditions EN 12900/CECOMAF ASHRAE LBP
Condensing temperature 55°C 54.4°C
Ambient temperature 32°C 32°C
Suction gas temperature 32°C 32°C
Liquid temperature no subcooling 32°C
101N2600
Wire Dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
[mm
] [Gauge] [m] [ft.] [m] [ft.]
2.5 12 2.5 8 5 16
4 12 4 13 8 26
6 10 6 20 12 39
10 8 10 33 20 66
*Length between battery and electronic unit
Accessories for BD1.4F-FSD Code number
Bolt joint for one compressor Ø: 16 m m 118-1917
Bolt joint in quantities Ø :16 m m 118-1918
Snap-on in quantities Ø:16 m m 118-1919
Terminal cover for electronic unit 105N9120
Automoblie fuse
DIN 7258
Main switch
12V: 15A
24V: 15A
min. 20A
Not
deliverable
from Secop
101N5200
refer to 101N2600 and 101N5200 Instructions for details
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.100.X4.02 / 520N1500 September 2013