Danfoss BD100CN Data sheet

BD100CN Direct Current Compressor R290 12-24V DC
General
Code number (without electronic units) 101Z0401
Electronic unit - High Speed 101N0290, 28 pcs: 101N0291
Additional approvals e4, C-Tick
Compressors on pallet 150
Application
Application LBP
Evaporating temperature °C -40 to -10
Voltage/max. voltage VDC 9.6 - 17 / 21.3 - 31.5
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S
38°C S
43°C S – Remarks on application: for stationary use only
°C 55 (65)
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
Motor
Motor type Variable speed
Resistance, all 3 windings (25°C) 1.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 120
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 4.3/0.32
Standard battery protection settings
Voltage 12V 24V
Cut out VDC 10.4 22.8
Cut in VDC 11.7 24.2
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.2 | 40°
Process connector location/I.D. mm | angle D 6.2 | 45°
Discharge connector location/I.D. mm | angle E 5.0 | 21°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks
(refer to 101N0290 Instructions for optional settings)
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
3
3
3
150 (polyolester)
B 135
B1 128
B2 73
2.00
870
July 2013 Manufactured by Secop for Danfoss - DEHC.ED.100.H7.02 / 520N1482 1/2
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
rpm \ °C -40 -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 2,500 30.6 40.2 51.9 66.0 71.4 82.9 103 126 3,100 36.0 49.0 64.6 83.0 90.0 105 130 160 3,800 40.5 56.6 75.6 98.0 106 124 154 189 4,400 44.6 62.4 83.4 108 117 137 170 209
Capacity (ASHRAE LBP) 12V DC, static cooling watt
rpm \ °C -40 -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 2,500 34.1 44.8 57.9 73.6 79.7 92.5 115 141 3,100 40.1 54.6 72.0 92.6 100 117 145 178 3,800 45.1 63.1 84.3 109 119 138 172 211 4,400 49.7 69.6 93.0 121 131 153 190 233
Power consumption 12V DC, static cooling watt
rpm \ °C -40 -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 2,500 35.7 39.8 44.8 50.5 52.5 56.4 62.3 67.8 3,100 41.9 48.9 56.3 64.0 66.7 71.8 79.4 86.5 3,800 48.7 58.6 68.6 78.5 81.8 88.1 97.5 106 4,400 57.4 69.1 80.8 92.5 96.4 104 115 125
Current consumption
(for 24V applications the following must be halfed) A
rpm \ °C -40 -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 2,500 2.97 3.32 3.74 4.21 4.38 4.70 5.19 5.65 3,100 3.49 4.07 4.69 5.34 5.56 5.98 6.61 7.20 3,800 4.06 4.88 5.71 6.54 6.82 7.35 8.12 8.86 4,400 4.78 5.76 6.74 7.71 8.04 8.66 9.58 10.44
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °C -40 -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 2,500 0.86 1.01 1.16 1.31 1.36 1.47 1.65 1.86 3,100 0.86 1.00 1.15 1.30 1.35 1.46 1.64 1.85 3,800 0.83 0.97 1.10 1.25 1.30 1.41 1.58 1.78 4,400 0.78 0.90 1.03 1.17 1.22 1.32 1.48 1.66
COP (ASHRAE LBP) 12V DC, static cooling W/W
rpm \ °C -40 -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 2,500 0.96 1.13 1.29 1.46 1.52 1.64 1.84 2.08 3,100 0.96 1.12 1.28 1.45 1.51 1.63 1.83 2.06 3,800 0.93 1.08 1.23 1.39 1.45 1.57 1.77 1.99 4,400 0.87 1.01 1.15 1.30 1.36 1.47 1.65 1.86
Test conditions EN 12900/CECOMAF* ASHRAE LBP*
Condensing temperature 45°C 45°C Ambient temperature 32°C 32°C Suction gas temperature 32°C 32°C Liquid temperature no subcooling 32°C
Operational errors errors shown by LED (optional)
Error code
5
Thermal cut-out of electronic unit
(If the refrigeration system has been too hea vi ly loaded, or if the ambient tem pe ra ture is high, the electronic unit will run too hot).
4
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 2,450 rpm).
3
Motor start error
(The rotor is blocked or the differential pres-sure in the refrigeration system is too high (>5 bar)).
2
Fan over-current cut-out
(The fan loads the electronic unit with more than 1A
).
1
peak
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
Compressor speed
Electronit unit Resistor
(R1) [Ω]
Code number
calculated
values [rpm]
Motor
speed
Control
circuit
current
[mA]
0 AEO 6
101N0290 with AEO
203 2,500 5 451 3,100 4 867 3,800 3
1700 4,400 2
In AEO (Adaptive Energy Optimizing) speed mode the BD com­ressor will always adapt its speed to the actual cooling demand.
Wire Dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
] [Gauge] [m] [ft.] [m] [ft.]
[mm
6 10 2.5 8 5 16
*Length between battery and electronic unit
Accessories for BD100CN Code number
Bolt joint for one compressor Ø :16 mm 118-1917 Bolt joint in quantities Ø: 16 mm 118-1918 Snap-on in quantities Ø:16 m m 118-1919 Remote kit (without cable) 105N9210
Standard automoblie fuse 12V: 30A DIN 7258 Main switch
24V: 15A
min. 30A
Not
deliverable
from Secop
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.100.H7.02 / 520N1482 July 2013