APP W HC pump instruction
APP W HC pumps
APP W HC 15 - 30
APP W HC 21-43
hpp.danfoss.com
ro-solutions.com
Table of Contents
1. Identification ...........................................................................2
2. System design ..........................................................................3
2.1 Open-ended systems with direct water supply...........................................3
2.2 Preferred RO system design and P&ID ...................................................3
2.3 Reversible pumps .......................................................................4
2.4 General comments......................................................................4
3. Building up the pump unit ..............................................................4
3.1 Mounting...............................................................................4
3.2 Direction of rotation ....................................................................5
3.3 Orientation .............................................................................5
3.4 Protection from too high pressures ......................................................5
3.5 Connections ............................................................................6
4. Initial start-up ...........................................................................7
5. Operation...............................................................................7
5.1 Temperature............................................................................7
5.2 Pressure ................................................................................8
5.3 Dry running.............................................................................8
5.4 Disconnection ..........................................................................8
5.5 Storage .................................................................................8
6. Service..................................................................................8
6.1 Warranty................................................................................8
6.2 Maintenance............................................................................8
6.3 Repair ..................................................................................8
1. Identification
PUMP
Type APP W HC 15 Code no. 180B5000
Serial no. XXXXXX02-XXX
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
2
AN283148361728en-000 402 | 10.2019
Instruction | APP W HC 15 - 30 pumps
2. System design
The design of the system must ensure that self-emptying of the pump during standstill is avoided.
The inlet pressure of the pump must never exceed the outlet pressure. This may typically occur in boosted or open-ended systems with direct water supply.
2.1 Open-ended systems with direct water supply
The pump is supplied with water directly from a feed pump.
The inlet pressure for APP W HC 15-30 must be at least 2 barg (29 psig).
To protect the pump from being damaged by peaks of high-pressure in case the pump stops momentarily, it is required to mount a low­pressure relief valve on the inlet line.
2.2 Preferred system design and P&ID
1. Dimension the inlet line to obtain mini­mum pressure loss (large flow, minimum pipe length, minimum number of bends/ connections, and fittings with small pressure losses).
2. Place an inlet filter (1) in front of the
APP W HC pump (2). Please consult Danfoss filter data sheet for guidance on how to select the right filter. Thoroughly clean pipes and flush system prior to start-up.
3. Place a monitoring pressure switch (3) set at min. inlet pressure between filter and pump inlet. The monitoring switch must stop the pump at pressures lower than minimum pressure.
4. Use flexible hoses (4) to minimize vibrations and noise.
5. In order to eliminate the risk of damage and cavitation, a positive pressure at the inlet (5) is always to be maintained at min. inlet pressure and max. inlet pressure.
Inlet
Outlet
It is recommend to install safety valve or a pressure relief valve (9) in order to avoid high-pressure peaks in case the pump stops momentarilly or is spinning backwards.
6. For easy system bleeding and flushing, a bypass non-return valve (6) is integrated in the APP W HC pump.
7. A non-return valve (7) in outlet can be installed in order to avoid backspin of the pump. The volume of water in the mem­brane vessel works as an accumulator and will send flow backwards in case of the pump stops momentarily.
8. A safety valve or a pressure relief valve (8) can be installed in order to avoid system damage as the Danfoss APP W HC pump creates pressure and flow immediately after start-up, regardless of any counter pressure.
Note: If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required between non-return valve and pump as protection against high-pressure peaks.
Feed
Media filter
PI
PI
PI PI
1 1
Fresh water
permeat flush
AN283148361728en-000 402 | 10.2019
M
9
3
PT
2
7
5
6
8
PI
Permeate
4
PI
Brine
3
3-5 mm [0.12-0.20 inch]
2.3 Reversible pumps
If exposed to high-pressure in the outlet while the electric motor is not energized, the pumps will start spinning backwards. This will not harm the pumps as long as the pressure in the inlet does not exceed the max. pressure peak of 10 barg (145 psig).
If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required as protection against high-pressure pulses and high-pressure in general.
Alternatively a high-pressure check valve can be mounted in the pump discharge line to prevent the pump from reversing.
The dotted setup ensures that the inlet pressure does not exceed 10 barg (145 psig), when a non­return valve is mounted in the inlet.
In order to avoid the risk of cavitation, the inlet pressure for APP W HC 15-30 must be min. 2 barg (29 psig).
The inlet line connection must be properly tightened, as possible entrance of air will cause cavitation.
2.4 General comments
Filtrat ion
A good filtration is vital to ensure a long and trouble-free life of the pump.
As water has very low viscosity, the APP W HC pumps have been designed with very narrow clearance in order to control internal leakage rates and improve component performance. Therefore it is important that the inlet water is filtered properly to minimize the wear of the pump.
The main filter must have a filtration efficiency of
99.98% at 10 μm. We recommend to use precision depth filter cartridges rated 10 μm abs. β10 ≥ 5000 (equivalent to a filtration efficiency of
99.98%). Bag filters and string wounded filter cartridges typically have only 50% filtration efficiency. This means that for each 100,000 parti­cles reaching the filter, 50,000 particles pass through it compared to only 20 particles in a filter with an efficiency of 99.98%.
For more information on the importance of proper filtration, please consult our publication “Filtration” (code number 521B1009), which also will provide you with an explanation of filtration definitions and a guidance on how to select the right filter.
Monitoring
It is recommended to continuously monitor the following conditions:
Filter clogging
Pressure (inlet- and outlet side of the pump)
3. Building up the pump unit
D
A: Elastic coupling B: Bell housing C: Motor shaft D: Pump flange
3.1 Mounting
1. Mount the coupling flush or maximum 1 mm offset from the pump shaft end. Ensure an air gap between coupling parts of 3-5 mm (0.12-0.2 inch).
2. Mount the bell housing on pump. Secure nuts with the right torque.
3. Measure the longest distance “A” from top of bell housing to the button of coupling claw.
4. Mount the coupling on motor shaft. Ensure the coupling and motor flange are not in contact with each other.
5. Measure from motor flange to the top of the coupling. That measurement “B” shall be 3-5 mm (0.12-0.2 inch) shorter than the measurement “A”.
(“A” and “B” can be found on the next
page).
4
AN283148361728en-000 402 | 10.2019
Instruction | APP W HC 15 - 30 pumps
6. Adjust respectively, verify the measure­ment, and secure both couplings with the right torques on the locking screws (see coupling operation & mounting instruction).
7. Mount the elastic gear ring and mount the bell housing/pump on the motor. After mounting it must be possible to move the elastic gear ring 3-5 mm (0.12 - 0.2 inch) axial “C”. The check can be done through the inspection hole of bell housing. Secure flange bolts with the right torque.
1: Bolts: torque 100 Nm ±10 Nm 2: Nuts: torque 40 Nm ±4 Nm 3: Torque see table below
1
3
2
2
C
1
If alternative mounting is desired, please contact Danfoss High Pressure Pumps.
Choose proper tolerances to ensure an easy mounting of the elastic coupling without use of tools.
Please take care to observe the recommended length tolerances of the chosen coupling, as an axial force on the pump will damage the pump.
(“C” can be found on the drawing below).
Thread size
Torque (Nm)
3.2 Direction of rotation
Is indicated by an arrow on the pump label.
PUMP
Type APP W HC 15 Code no. 180B5000
Serial no. XXXXXX02-XXX
3.3 Orientation
The pump can be mounted/orientated in any horizontal direction with the inlet and the outlet pointing upwards, downwards or to either side.
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
M5 M6 M8 M10
2 4.8 10 17
3.4 Protection from too high pressures
The pump should be protected against too high pressure by means of a safety valve or a pressure relief valve.
The valve should be placed as close to the pump as possible.
The opening characteristics of the valve must not result in peak pressures higher than 132 barg (1914 psig).
We recommend the use of flexible soft hoses both in the inlet and in the outlet lines.
AN283148361728en-000 402 | 10.2019
5
The valve outlet must not be connected directly to the pump suction line. It must be connected directly to the drain.
Inlet
3.5 Connections
I: Inlet O: Outlet C: Bleeding D: Parallel key
Outlet
Inlet
Outlet
C
I
O
C
C
D
Description APP W HC 15 - 30
E Parallel key,
DIN 6885
F Bleeding G ¼”, Hexagon AF = 6 mm
I Inlet port M60 x 1.5; depth 24 mm
O Outlet port M60 x 1.5; depth 24 mm
Mounting flange ISO 3019-2 180B4TW
mm 12 × 8 × 70
in 0.47 × 0.31 × 2.76
For more details on the accessories, please contact Danfoss High Pressure Pumps. Possible extension see next page.
6
AN283148361728en-000 402 | 10.2019
C
Accessories Typ e Code no.
3” inlet hose kit - 2m (79”) 3 Victaulic 180Z014 4
2½” outlet high pressure hose 120 bar
2½” outlet high pressure hose 120 bar
3” inlet connector M60 - 3” Victaulic
Non-return valve (outlet) Super Duplex M60 - 2 ½” Victaulic
1)
The installation instuction for Style 77DX is located in the Victaulic document
2 ½” Victaulic 1 m Style 77DX
2 ½” Victaulic 1.78 m Style 77DX
Style 77DX
1)
1)
1)
I-100 Field Installation Handbook (htpp://static.victaulic.com)
180Z100 9
180Z100 8
180B3208
180H0055
Instruction | APP W HC 15 - 30 pumps
4. Initial start-up
5. Operation 5.1 Tempe ratu re
1. Flush inlet line before connecting the pump, to remove possible impurities from pipes, hoses etc.
2. Connect pump inlet to inlet line and flush the pump for 5 min. by means of the internal flushing valve, to remove possible impurities from pipes, hoses etc.
3. Loosen top bleeding plug “C” (see item 3.5) using an allen key (only plugs with internal hexagan sockets). Retighten the plug, when water APP W HC appears from the bleeding plug.
4. Make sure that the direction of rotation of the electric motor corresponds to the direc­tion of rotation of the pump (see label on pump).
5. Now the pump is ready for start-up.
WARNING Make sure that the direction of rotation of the electric motor corresponds to the direction of rotation of the pump (see label on pump). Otherwise the pump will be damaged if a check valve is placed between pump and feed pump.
O
I
Internal flushing valve
Fluid temperature: Min. +2°C to max. +50°C (Min. +35.6°F to max. +122°F)
Ambient temperature: Min. +2°C to max. +50°C (Min. +35.6°F to max. +122°F)
In case of lower operating temperatures, please contact Danfoss High Pressure Pumps.
NaCl vs. temperature
º
80
C
Duplex
70
60
50
316L
40
30
The chart below illustrates the corrosive resistance of different types of stainless steel related to NaCl concentration and temperature.
The APP W HC water pump is made of Duplex and Super Duplex.
If the water pump is operated above the Super Duplex line, always flush water pump with fresh water at operation stop in order to minimize the risk of crevice corrosion.
Super Duplex
20
100
160 1600
AN283148361728en-000 402 | 10.2019
1000
10 000
16000
100 000
160000
CI ppm
NaCI ppm
-
7
5.2 Pressure
The inlet pressure for APP W HC 15-30 must be min. 2 barg (29 psig) and max. 5 barg (72.5 psig). At lower pressures the pump will cavitate, resulting in damage of the pump.
Max. inlet pressure peak (e.g. in case the pump stops momentarily) up to 10 barg (145 psig) are acceptable.
Max. pressure on the pump’s outlet line should be limited at 120 barg (1750 psig) continuously,
Note: The pump unit should include a pressure gauge on the high-pressure side.
5.3 Dry running
When running, the pump must always be connected to the water supply in order to avoid damage if it should run dry.
5.4 Disconnection
If the inlet line is disconnected from the water supply, the pump will be emptied of water through the disconnected inlet line.
When starting up again, follow the bleeding procedure described under section 4: Initial start up.
5.5 Storage
Storage temperature: Min. -40°C to max. +70°C (Min. -40°F to max. +158°F)
When preparing the pump for long-term storage or for temperatures below the freezing point, flush the pump with an anti-freeze medium type monopropylene glycol to prevent internal corrosion or frost in the pump.
For further information on anti-freeze media, please contact Danfoss High Pressure Pumps.
Recommended procedure:
1. Disconnect the water supply to the pump.
2. Through the lower bleeding plug, empty the pump housing of water and close it again.
3. Connect the pump to a tank containing anti-freeze additive. Connect a hose to the inlet port of the pump and via another hose return the flow from the outlet port to the tank with antifreeze additives.
4. Quickly start and stop the pump. Make sure that the pump does not run dry.
The pump is now protected against
internal corrosion and frost.
Storage of pump that have been in operation:
For shorter periods of storage flush the pump with permeate rotating the pump for 10 sec., empty permeate and store. For long term storage (more than 2 months) Danfoss recom­mends servicing the product and clean any biological growth of the surfaces. Store the pump dry without water inside.
6. Service
8
6.1 Warranty
Danfoss APP W HC pumps are designed for long operation, low maintenance and reduced lifecycle costs.
Provided that the pump has been running according to the Danfoss specifications, Danfoss guarantees 8,000 hours service-free operation, however, max 18 months from date of produc­tion.
All pumps comes with NBR seals and shaft seal, ideal for water. When pumping water mixed with chemicals, we recommend assessing or testing the impact from the chemicals on the pump materials (see Part List for full overview of materials). Danfoss product warranty doesn´t cover cases where chemicals are the root cause of the failure or claim. Additionally, use of certain chemicals may lead to increase wear and require part replacement more often than the Recom­mended Service Intervals, which are based on water.
AN283148361728en-000 402 | 10.2019
If Danfoss recommendations concerning system-design are not followed, it will strongly influence the life of the APP W HC pumps.
Other factors that affect pump performance and lifetime include:
- Running the pump at speed outside
specifications.
- Supplying the pump with water at
temperature higher than recommended.
- Running the pump at inlet pressure outside
specifications.
- Running the pump at outlet pressure
outside the specifications.
Instruction | APP W HC 15 - 30 pumps
6.2 Maintenance
After 8,000 hours of operation, it is strongly recommended to inspect the pump and change
any worn parts, e.g. pistons and shaft seal. This is done in order to prevent a potential breakdown of the pump. If the parts are not replaced, more frequent inspection is recom­mended according to our guidelines.
Standstill:
The APP W HC pumps are made of Duplex/Super Duplex materials with excellent corrosion properties. It is however, always recommended
to flush the pump with fresh water when the system is shut down.
When stopping the pump for more than 1 day flush the ppump with permeate be rotating the pump for 10 sec. Flushing through the flashing valve of the pump without rotating the pump is not enought for cleaning the inside of the pump. The pump can be flushed with biocicde like the membranes. The biocide must be compatible with the materials used in our pump (materials can be found in the parts list in the Operating Guide.
6.3 Repair
In case of irregular function of the APP W HC, please contact Danfoss High Pressure Pumps sales organisation.
AN283148361728en-000 402 | 10.2019
9
Danfoss A/S High Pressure Pumps Nordborgvej 81 DK-6430 Nordborg Denmark
© Danfoss | DCS (im) | 2019.10