Danfoss AK-XM 205B Installation guide

Instructions
AK-XM 205B
080Z0017
-20°< t
-0°F < t 0 - 95% RH, non condensing IP10 / VBG4 UL: E357029
AI x 8 DO x 8
< 55°C17
amb
< 130°F
amb
AK-XM 205B
max. 10 V
RI8HM602 09-2018
Keep the safety distance Low and high voltage must not be connected to the same output group
Max. 230 V
AC-1: max. 4 A (ohmic) AC-15: max. 3 A (Inductive)
Point
Override (off / Auto / on)
Terminal 9: 12 V Terminal10: 5 V Terminal 21: 12 V Terminal 22: 5 V
Terminal 11, 12, 23, 24 :
Signal Signal
S (sensor)
Pt 1000 ohm/0°C
S1 S2 Saux1 Saux2 SSA SdA
P (pressure)
AKS 32R AKS 2050
P0A P0B PcA PcB
AKS 32
Paux
U (voltage)
...
On/Off Ext.
Main switch
Day/ Night
Door
DO Comp 1
Comp 2
Fan 1
Alarm
type
Pt 1000
AKS 32R AKS 2050 MBS 8250
-1 - xx bar
AKS 32
-1 - zz bar
0 - 5 V 0 - 10 V
Active at:
Closed
/
Open
Active at:
ON
/
OFF
Address
(Communication module)
(Controller)
Signal Signal type /
Active at
Module Point Terminal
1 (AI 1) 1 - 2
2 (AI 2) 3 - 4
3 (AI 3) 5 - 6
4 (AI 4) 7 - 8
5 (AI 5) 13 - 14
6 (AI 6) 15 - 16
7 (AI 7) 17 - 18
8 (AI 8) 19 - 20
9 (DO 1) 25-26-27
10 (DO 2) 28-29-30
11 (DO 3) 31-32-33
12 (DO 4) 34-35-36
13 (DO 5) 37-38-39
14 (DO6) 40-41-42
15 (DO7) 43-44-45
16 (DO8) 46-47-48
The Product contains electrical components And may not be disposed together with domestic waste. Equipment must be separate collected with Electrical and Elec­tronic waste. According to Local and currently valid legislation.
2 Instructions RI8HM602 © Danfoss 09/2018 AK-XM 205B