* DO1 and DO2 are 16 A relays. DO3 and DO4 are 8 A relays. Max. load must be kept.
** Gold plating ensures make function with small contact loads
*** UL-approval based on 30000 couplings
4 (1) A
Min. 100 mA**
10 A Resistive
5FLA, 30LRA
10 A Resistive
5FLA, 30LRA
6 A Resistive
3FLA, 18LRA
131 VA Pilot duty
4 A Resistive
131 VA Pilot duty
Koordineret afrimning
Coordinated defrost
Data communication
Type: Pt 1000 (1000 Ω /0°C ) /
Ptc 1000 (TYPE) /
NTC-M2020 (5000 Ω / 25°C)
( o06)
LON RS485
MOD-bus
RI8RE3ML 10-2016
o61 — Electrical connections - Conexão elétrica
1 2
3 4
*)
*)
*)
*)
5
*) DI1, DI2: AU: Guld, Gold, Or, Oro l = max. 15 m
3 Åbn parameter o61 og indstil elforbindelsesnummeret heri
4 Vælg derefter et sæt af forudindstillinger fra tabellen til højre
5 Åbn parameter o62 og indstil nummeret for sættet af forudindstil-
linger
6 Åbn parameter r12 og start reguleringen
7 Se oversigten over fabriksindstillinger igennem. — Foretag de nød-
vendige ændringer i de respektive parametre
Hjælpeskema til indstillinger
(quick-setup)
Sæt af forudindstillinger (o62)123
Temperatur (SP)4°C2°C-24°C
Max. temp. indstilling (r02)6°C4°C-22°C
Min. temp. indstilling (r03)2°C0°C-26°C
Alarmgrænse høj (A13)10°C8°C-15°C
Alarmgrænse lav (A14)-5°C-5°C-30°C
Interval imellem afrimn. (d03)6 h6h12h
Afrimningsføler: 0=time,1=S5, 2=S4 (d10)011
DI1 konfiguration (o02)101010
Afr. stop
på tid
8 Ved netværk. Indstil adressen i o03 og send derefter adressen til
gatewayen/systemenheden med indstillingen o04.
Sæt 1-3: Indstillingerne i de grå felter bliver ændret
ParametreVariant af AK-CCMin.Funktion Koder 12345
Normal drift
Temperatur (setpunkt)----50.0°C50.0°C2.0°C
Termostat
Differens***r010.1 K20.0 K2.0 K
Max. begrænsning af setpunktsindstilling***r02-49.0°C50.0°C50.0°C
Min. begrænsning af setpunktsindstilling***r03-50.0°C49.0°C-50.0°C
Justering af temperaturvisningr04-20.0 K20.0 K0.0 K
Temperaturenhed (°C/°F)r05°C°F°C
Korrektion af signalet fra S4r09-10.0 K10.0 K0.0 K
Korrektion af signalet fra S3r10-10.0 K10.0 K0.0 K
Manuel service, Stop regulering, Start regulering (-1, 0, 1)r12-110
Referenceforskydning under natdriftr13-20.0 K20.0 K0.0 K
Definition og evt. vægtning af termostatfølere - S4%
(100%=S4, 0%=S3)
Aktivering af referenceforskydning r40r39OFFONOFF
Værdi for referenceforskydning (aktiveres via r39 eller DI)r40-50.0 K50.0 K0.0 K
Alarm
Forsinkelse på temperaturalarmA030 min240 min30 min
Forsinkelse på døralarm***A040 min240 min60 min
Forsinkelse på temperaturalarm efter afrimningA120 min240 min90 min
Høj alarmgrænse***A13-50.0°C50.0°C8.0°C
Lav alarmgrænse***A14-50.0°C50.0°C-30.0°C
Alarm forsinkelse DI1A270 min240 min30 min
Alarm forsinkelse DI2A280 min240 min30 min
Signal til alarmtermostaten. (100%=S4, 0%=S3)A360%100%100%
Kompressor
Min. ON-tidc010 min30 min0 min
Min. OFF-tidc020 min30 min0 min
Forsinkelsestid for indkobling af compr. 2c050 sec900 sec5 sec
Kompressorrelæ 1 skal koble modsat
(NC-funktion)
Forsinkelsestid for indkobling af kompressor 2 under afrimningc920 s30 s5 s
Afrimning
Afrimningsmetode (ingen/EL/GAS)d01noGASGAS
Afrimnings-stoptemperaturd020.0°C25.0°C6.0°C
Interval mellem afrimningsstarterd030 hours 240 hours 8 hours
Max. afrimningsvarighedd040 min360 min45 min
Tidsforskydning på afrimningsindkoblingen ved opstartd050 min240 min0 min
Afdrypningstidd060 min60 min0 min
Forsinkelse på ventilatorstart efter afrimningd070 min60 min0 min
Ventilator-starttemperaturd08-50.0°C0.0°C-5.0°C
Ventilator indkoblet under afrimning
r150%100%100%
c300
d09021
værdi
OFF
Max.-
værdi
1
ON
Fabriks-
indstil-
ling
0
OFF
0: stoppet
1: Kører
2: Kører under pump down og afrimning
Afrimningsføler (0=tid, 1=S5, 2=S4)d10020
Pump down forsinkelsed160 min60 min0 min
Max. opsummeret køletid imellem to afrimningerd180 hours48 hours0 hours
Behovstyret afrimning - S5 temperaturens tilladte variation ved isopbygning. På centralanlæg vælges 20 (=off)
Varighed af -d- i displayetd405 min240 min30 min
Ventilator
Ventilatorstop ved udkoblet kompressorF01noyesno
Forsinkelse af ventilatorstopF020 min30 min0 min
Ventilatorstop temperatur (S5)F04-50.0°C50.0°C50.0°C
Aktuel temperaturmåling til HACCP funktionenh01
Den sidst registrerede spidstemperaturh10
Valg af funktion og føler til HACCP funktionen. 0=ingen HACCP funktion. 1= S4 benyttes
(evt. også S3). 2=S5 benyttes
Alarmgrænse for HACCP funktionenh12-50.0°C50.0°C8.0°C
Forsinkelsestid for HACCP alarmenh130 min.240 min. 30 min.
Vælg signal til HACCP funktionen. S4% (100%=S4, 0%=S3)h140%100%100%
Realtidsur
Seks starttidspunkter for afrimning.
Indstilling af timer.
0=OFF
Seks starttidspunkter for afrimning.
Indstilling af minutter
0=OFF
Ur - Timeindstilling***t070 hours23 hours0 hours
Ur - Minutindstilling***t080 min59 min0 min
Ur - Indstilling af dato***t451311
Ur - Indstilling af måned***t461121
Ur - Indstilling af år***t470990
Diverse
Forsinkelse af udgangssignaler efter opstarto010 s600 s5 s
Indgangssignal på DI1. Funktion:
(0=ikke anvendt, 1=status på DI1. 2=dørfunktion med alarm ved åben. 3=døralarm
ved åben. 4=afrimningsstart (pulssignal). 5=ekstern hovedafbryder. 6=natdrift. 7=skift
reference (r40 aktiveres). 8=alarmfunktion ved sluttet. 9=alarmfunktion ved åben.
10=møbelrengøring (pulssignal).
Netværksadresseo0302400
On/Off omskifter (Service Pin meddelelse)
VIGTIGT! o61 skal indstilles før o04
Adgangskode 1 (samtlige indstillinger)o0501000
Anvendt følertype (Pt /PTC/NTC)o06PtntcPt
Udlæsning af softwareversiono08
Display step = 0.5 (normal 0.1 ved Pt føler)o15noyesno
Max holdetid efter koordineret afrimningo160 min60 min20
Vælg signal til displayvisningen. S4%
(100%=S4, 0%=S3)
Indgangssignal på DI2. Funktion:
(0=ikke anvendt, 1=status på DI2. 2=dørfunktion med alarm ved åben. 3=døralarm
ved åben. 4=afrimningsstart (pulssignal). 5=ekstern hovedafbryder. 6=natdrift. 7=skift
reference (r40 aktiveres). 8=alarmfunktion ved sluttet. 9=alarmfunktion ved åben.
10=møbelrengøring (pulssignal).
Konfiguration af lysfunktionen (relæ 4)
1=ON under dagdrift. 2=ON / OFF via datakommunikation. 3=ON følger DI-funktionen,
når DI er valgt til dørfunktion eller til døralarm
Aktivering af lysrelæ (kun hvis o38=2)o39OFFONOFF
Kantvarme On-tid under dagdrifto410%100%100
Kantvarme On-tid under natdrifto420%100%100
Kantvarme periodetid (On tid + Off tid)o436 min60 min10 min
Møbelrengøring. 0= ingen møbelrengørring 1= kun ventilatorer. 2 Alle udgange er OFF ***o46020
Valg af EL-diagram. Se oversigten side 2.*o61151
Overfør et sæt af forudindstillinger. Se oversigten på forrige side*o62030
Adgangskode 2 (delvis adgang)***o6401000
Gem apparatets nuværende indstillinger på programmeringsnøglen. Vælg selv nummer.
Hent et sæt indstillinger fra programmeringsnøglen (tidligere gemt via o65 funktionen)o660250
Overskriv regulatorens fabriksindstillinger med de nuværende indstillinger o67OFFOnOFF
Service
Statuskoder er vist på side 5S0-S32
Temperaturen målt med S5 føleren***u09
Status på DI1 indgangen. 1=sluttetu10
Temperaturen målt med S3 føleren***u12
Status på natdrift (on eller off) 1=sluttet***u13
Temperaturen målt med S4 føleren***u16
Termostattemperaturenu17
Aflæse den øjeblikkelige reguleringsreferenceu28
Status på DI2 udgangen. 1=sluttetu37
Temperaturen der udlæses på displayetu56
Målt temperatur til alarmtermostatenu57
Status på relæet til køling**u58
Status på relæet til ventilator**u59
Status på relæet til afrimning**u60
Status på relæet til kantvarme**u61
Status på relæet til alarm**u62
Status på relæet til lys**u63
Status på relæet til kompressor 2**u67
Status på relæet til kompressorblæser**u71
t01-t060 hours23 hours0 hours
t11-t160 min59 min0 min
12345
h11020
o020100
o04OFFONOFF
o170%100%100%
o370100
o38131
o650250
*) Kan kun indstilles, når reguleringen er stoppet (r12=0)
**) Kan styres manuelt, men kun når r12 = -1
***) Med adgangskode 2 begrænses adgangen til disse menuer
1. Tryk på den øverste knap til der vises en
parameter
2. Tryk på øverste eller nederste knap og
find hen til den parameter, du vil indstille
3. Tryk på den midterste knap indtil værdien for parameteren vises
Indstille temperaturen
1. Tryk på den midterste knap til temperaturværdien vises
2. Tryk på øverste eller den nederste knap
og find den nye værdi
3. Tryk på den midterste knap for at af-
slutte indstillingen.
Lysdiode
= køling
= afrimning
= ventilator i gang
Blinker hurtigt ved alarm
4. Tryk på øverste eller nederste knap og
find den nye værdi
5. Tryk igen på den midterste knap for at
Aflæse temperaturen ved afrimningsføleren
• Kort tryk på den nederste knap
HACCP
Funktionen er aktiv
fastlåse værdien.
Manuel start eller stop af en afrimning
Udkoble alarmrelæ / se alarmkode
• Kort tryk på den øverste knap
• Tryk på den nederste knap i 4 sekunder.
(Dog ikke ved application 4)
Se HACCP registrering
1. Langt tryk på den midterste knap til h01
vises
2. Vælg ønsket h01 - h10
3. Se værdien ved kort tryk på den midterste knap.
Visning af fejlkodeVisning af alarmkodeVisning af statuskode
E 1Fejl i regulatorA 1Høj-temperatur alarmS0Der reguleres
E 6Batteriet skal skiftes + kontroller urA 2Lav-temperatur alarmS1Venter på at den koordinerede afrimning
E 25S3 føler fejlA 4Dør-alarmS2ON-tid Kompressor
E 26S4 føler fejlA 5Max. Hold timeS3OFF-tid kompressor
E 27S5 føler fejlA 15DI 1 alarmS4Afdrypningstid
A 16DI 2 alarmS10Køling stoppet af hovedafbryder
A 45Standby modeS11Køling stoppet af termostat
A 59MøbelrengøringS14Afrimningssekvens. Afrimer
A 60HACCP alarmS15Afrimningssekvens. Ventilatorforsinkelse
Fabriksindstilling
Hvis du får behov for at vende tilbage til de fabriksindstillede værdier, kan det ske således:
- Afbryd forsyningsspændingen til regulatoren
- Hold den øverste og nederste knap inde samtidig med at du igen tilslutter forsyningsspændingen.
afsluttes
S17Dør åben (åben DI indgang)
S20Nødkøling
S25Manuel regulering af udgange
S29Møbelrengøring
S30Tvangskøling
S32Forsinkelse af udgange ved opstart
nonAfrimningstemperaturen kan ikke vises. Der
2 Select electric connection based on the drawings on page 2
3 Open parameter o61 and set the electric connection number in it
4 Now select one of the preset settings from the table on the right-
hand side
5 Open parameter o62 and set the number for the array of preset-
tings
6 Open parameter r12 and start the regulation
7 Go through the survey of factory settings. Make any necessary
Auxiliary table for settings
(quick-setup)
Preset settings (o62)123
Temperature (SP)4°C2°C-24°C
Max. temp. setting (r02)6°C4°C-22°C
Min. temp. setting (r03)2°C0°C-26°C
Alarm limit high (A13)10°C8°C-15°C
Alarm limit low (A14)-5°C-5°C-30°C
Interval between defrost (d03)6 h6h12h
Defrost sensor: 0=time,1=S5, 2=S4 (d10)011
DI1 configuration (o02)101010
Defrost
stop on
time
Defrost stop
changes in the respective parameters.
8 For network. Set the address in o03 and then transmit it to the
gateway/system unit with setting o04.
Array 1-3: The settings in the grey fields will be changed
Function Codes 12345
Normal operation
Temperature (set point)----50.0°C50.0°C2.0°C
Thermostat
Differential***r010.0 K20.0K2.0 K
Max. limitation of setpoint setting***r02-49.0°C50°C50.0°C
Min. limitation of setpoint setting***r03-50.0°C49.0°C-50.0°C
Adjustment of temperature indicationr04-20.0 K20.0 K0.0 K
Temperature unit (°C/°F)r05°C°F°C
Correction of the signal from S4r09-10.0 K+10.0 K0.0 K
Correction of the signal from S3r10-10.0 K+10.0 K0.0 K
Manual service, stop regulation, start regulation (-1, 0, 1)r12-110
Displacement of reference during night operationr13-20.0 K20.0 K0.0 K
Definition and weighting, if applicable, of thermostat sensors - S4% (100%=S4, 0%=S3)r150%100%100%
Activation of reference displacement r40r39OFFONOFF
Value of reference displacement (activate via r39 or DI)r40-50.0 K50.0 K0.0 K
Alarm
Delay for temperature alarmA030 min240 min 30 min
Delay for door alarm***A040 min240 min 60 min
Delay for temperature alarm after defrostA120 min240 min 90 min
High alarm limit***A13-50.0°C50.0°C8.0°C
Low alarm limit***A14-50.0°C50.0°C-30.0°C
Alarm delay DI1A270 min240 min 30 min
Alarm delay DI2A280 min240 min 30 min
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)A360%100%100%
Compressor
Min. ON-timec010 min30 min0 min
Min. OFF-timec020 min30 min0 min
Time delay for cutin of comp.2c050 sec900 sec5 sec
Compressor relay 1 must cutin and out inversely
(NC-function)
Time delay for cutin of compressor 2 during defrostc920 s30 s5 s
Defrost
Defrost method (none/EL/GAS)d01noGASGAS
Defrost stop temperatured020.0°C25.0°C6.0°C
Interval between defrost startsd030 hours
Max. defrost durationd040 min360 min 45 min
Displacement of time on cutin of defrost at start-upd050 min240 min0 min
Drip off timed060 min60 min0 min
Delay for fan start after defrostd070 min60 min0 min
Fan start temperatured08-50.0°C0.0°C-5.0°C
Fan cutin during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
Defrost sensor (0=time, 1=S5, 2=S4)d10020
Pump down delayd160 min60 min0 min
Max. aggregate refrigeration time between two defrostsd180 hours 48 hours 0 hours
Defrost on demand - S5 temperature’s permitted variation during frost build-up. On
central plant choose 20 K (=off)
Max. duration of -d- in displayd405 min240 min 30 min
Fan
Fan stop at cutout compressorF01noyesno
Delay of fan stopF020 min30 min0 min
Fan stop temperature (S5)F04-50.0°C50.0°C50.0°C
Actual temperature measurement for the HACCP functionh01
Last registered peak temperatureh10
Selection of function and sensor for the HACCP function. 0 = no HACCP function. 1 = S4
used (maybe also S3). 2 = S5 used
Alarm limit for the HACCP functionh12-50.0°C50.0°C8.0°C
Time delay for the HACCP alarmh130 min. 240 min. 30 min.
Select signal for the HACCP function. S4% (100% = S4, 0% = S3)h140%100%100%
Real time clock
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours***t070 hours 23 hours 0 hours
Clock - Setting of minute***t080 min59 min0 min
Clock - Setting of date***t451311
Clock - Setting of month***t461121
Clock - Setting of year***t470990
Miscellaneous
Delay of output signals after start-upo010 s600 s5 s
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm when open. 3=door alarm
when open. 4=defrost start (pulse-signal). 5=ext.main switch. 6=night operation
7=change reference (activate r40). 8=alarm function when closed. 9=alarm function
when open. 10=case cleaning (pulse signal).
Network addresso0302400
On/Off switch (Service Pin message)
IMPORTANT! o61 must be set prior to o04
Access code 1 (all settings)o0501000
Readout of Software versiono06
Display step = 0.5 (normal 0.1 at Pt sensor)o15noyesno
Max hold time after coordinated defrosto160 min60 min20
Select signal for display view. S4% (100%=S4, 0%=S3)o170%100%100%
Input signal on DI2. Function:
(0=not used. 1=status on DI2. 2=door function with alarm when open. 3=door alarm
when open. 4=defrost start (pulse-signal). 5=ext. main switch 6=night operation
7=change reference (activate r40). 8=alarm function when closed. 9=alarm function
when open. 10=case cleaning (pulse signal).
Configuration of light function (relay 4)
1=ON during day operation. 2=ON / OFF via data communication. 3=ON follows the DIfunction, when DI is selected to door function or to door alarm
Activation of light relay (only if o38=2)o39OFFONOFF
Rail heat On time during day operationso410%100%100
Rail heat On time during night operationso420%100%100
Rail heat period time (On time + Off time)o436 min60 min10 min
Case cleaning. 0=no case cleaning. 1=Fans only. 2=All output Off.***o46020
Selection of EL diagram. See overview page 2*o61*151
Download a set of predetermined settings. See overview previous page. *o62*030
Access code 2 (partly access)***o6401000
Save the controllers present settings to the programming key. Select your own number. o650250
Load a set of settings from the programming key (previously saved via o65 function)o66*0250
Replace the controllers factory settings with the present settingso67OFFOnOFF
Service
Status codes are shown on page 5S0-S32
Temperature measured with S5 sensor***u09
Status on DI1 input. on/1=closedu10
Temperature measured with S3 sensor***u12
Status on night operation (on or off) 1=closed***u13
Temperature measured with S4 sensor***u16
Thermostat temperatureu17
Read the present regulation referenceu28
Status on DI2 output. on/1=closedu37
Temperature shown on displayu56
Measured temperature for alarm thermostatu57
Status on relay for cooling**u58
Status on relay for fan**u59
Status on relay for defrost**u60
Status on relay for railheat**u61
Status on relay for alarm**u62
Status on relay for light**u63
Status on relay for compressor 2**u67
Status on relay for compressor fan**u71
*) Can only be set when regulation is stopped (r12=0)
**) Can be controlled manually, but only when r12=-1
***) With access code 2 the access to these menus will be limited
E 1Fault in controllerA 1High temperature alarmS0Regulating
E 6Change battery + check clockA 2Low temperature alarmS 1Waiting for end of the coordinated defrost
E 25S3 sensor errorA 4Door alarmS 2ON-time Compressor
E 26S4 sensor errorA 5Max. Hold timeS 3OFF-time Compressor
E 27S5 sensor errorA 15DI 1 alarmS 4Drip-off time
A 16DI 2 alarmS 10Refrigeration stopped by main switch
A 45Standby modeS 11Refrigeration stopped by thermostat
A 59Case cleaningS 14Defrost sequence. Defrosting
A 60HACCP alarmS 15Defrost sequence. Fan delay
S 17Door open (open DI input)
S 20Emergency cooling
S 25Manual control of outputs
S 29Case cleaning
S 30Forced cooling
S 32Delay of output at start-up
nonThe defrost temperature cannot be dis-
played. There is stop based on time
-d-Defrost in progress
PSPassword required
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep upper and lower button depressed at the same time as you recon nect the supply voltage
2 Selecione a conexão elétrica com base nos desenhos na página 2
3 Abra o parâmetro o61 e programe nele o número da conexão
elétrica
4 Agora selecione um dos ajustes predefinidos na tabela à direta
5 Abra o parâmetro o62 e programe o número da matriz
de pré-ajustes.
6 Abra o parâmetro r12 e inicie a regulagem
7 Percorra a pesquisa de ajustes de fábrica. Faça as alterações ne-
cessárias nos parâmetros respectivos.
Tabela auxiliar de ajustes
(setup rápido)
Ajustes predefinidos (o62)123
Temperatura (SP)4°C2°C-24°C
Ajuste de temp. máx. (r02)
Ajuste de temp. mín. (r03)
Limite de alarme alto (A13)
Limite de alarme baixo (A14)
Intervalo entre degelos (d03)6 h6h12h
Sensor de degelo: 0=tempo, 1=S5, 2=S4
(d10)
DI1 configurações (o02)101010
Parada
de degelo no
horário
10°C8°C-15°C
-5°C-5°C-30°C
Parada de degelo
6°C4°C-22°C
2°C0°C-26°C
011
8 Para rede. Programe o endereço em o03 e inicie a função de
unidade de gateway/sistema com ajuste o04.
Matriz 1-3: As definições dos campos cinzas serão alteradas
ParâmetrosVariante da AK-CC
Função
Operação normal
Temperatura (ponto de ajuste)----50.0°C50.0°C2.0°C
Termostato
Diferencial***r010.0 K20.0K2.0 K
Limitação máx. do ponto de ajuste***r02-49.0°C50°C50.0°C
Limitação mín. do ponto de ajuste***r03-50.0°C49.0°C-50.0°C
Ajuste da indicação de temperaturar04-20.0 K20.0 K0.0 K
Unidade de temperatura (°C/°F)r05°C°F°C
Correção do sinal de S4r09-10.0 K+10.0 K0.0 K
Correção do sinal de S3r10-10.0 K+10.0 K0.0 K
Serviço manual, regulagem da parada, regulagem da partida (-1, 0, 1)r12-110
Deslocamento de referência durante operação noturnar13-20.0 K20.0 K0.0 K
Definição e pesagem, se aplicável, dos sensores do termostato - S4% (100%=S4, 0%=S3)r150%100%100%
Ativação do deslocamento de referência r40r39OFFONOFF
Valor do deslocamento de referência (ativar via r39 ou DI)r40-50.0 K50.0 K0.0 K
Alarme
Atraso do alarme de temperaturaA030 min240 min 30 min
Atraso do alarme da porta***A040 min240 min 60 min
Atraso do alarme de temperatura após degeloA120 min240 min 90 min
Limite de alarme superior***A13-50.0°C50.0°C8.0°C
Limite de alarme inferior***A14-50.0°C50.0°C-30.0°C
Atraso de alarme DI1A270 min240 min 30 min
Atraso de alarme DI2A280 min240 min 30 min
Sinal do termostato do alarme. S4% (100%=S4, 0%=S3)A360%100%100%
Compressor
Tempo mínimo LIGADOc010 min30 min0 min
Tempo mínimo DESLIGADOc020 min30 min0 min
Tempo de atraso de ativação do comp.2c050 sec900 sec5 sec
O relé do compressor 1 deve ativar e desativar inversamente
(função NC)
Tempo de atraso de desativação do compressor 2 durante o descongelamentoc920 s30 s5 s
Degelo
Método de degelo (nenhum/EL/GAS)d01noGASGAS
Temperatura de parada do degelod020.0°C25.0°C6.0°C
Intervalo entre inícios de degelosd030 hours
Duração máx. do degelod040 min360 min 45 min
Deslocamento de tempo na ativação do degelo no início de operaçõesd050 min240 min0 min
Tempo de gotejamentod060 min60 min0 min
Atraso da partida do ventilador após degelod070 min60 min0 min
Temperatura de partida do ventiladord08-50.0°C0.0°C-5.0°C
Ativação do ventilador durante degelo
Códi-
12345
gos
c300
d09021
Valor
mín.
OFF
240 hours
Valor
máx.
1
ON
Ajuste
de
fábrica
0
OFF
8 hours
0: Parado
1: Funcionando
2: Funcionando durante desac. da bomba e degelo
Sensor de degelo (0=tempo, 1=S5, 2=S4)d10020
Atraso de desaceleração da bombad160 min60 min0 min
Tempo de refrigeração agregado máx. entre dois degelosd180 hours 48 hours 0 hours
Degelo sob demanda - variação permitida da temperatura do S5 durante acúmulo de
geada. Na fábrica central escolha 20 K (=desligado)
Duração máx. de -d- no displayd405 min240 min 30 min
Ventilador
Parada do ventilador na desativação do compressorF01noyesno
Atraso de parada do ventiladorF020 min30 min0 min
Temperatura de parada do ventilador (S5)F04-50.0°C50.0°C50.0°C
Medição de temperatura a real da função HACCPh01
Última temperatura de pico registradah10
Seleção de função e sensor da função HACCP. 0 = sem função HACCP. 1 = S4 usado (talvez
também S3). 2 = S5 usado
Limite de alarme da função HACCPh12-50.0°C50.0°C8.0°C
Tempo de atraso do alarme HACCPh130 min.240 min. 30 min.
Seleção de sinal da função HACCP. S4% (100% = S4, 0% = S3)h140%100%100%
Relógio em tempo real
Seis horários de início de degelo.
Ajuste de horas.
0=DESLIGADO
Seis horários de início de degelo.
Ajuste de minutos.
0=DESLIGADO
Relógio - Ajuste de horas***t070 hours 23 hours 0 hours
Relógio - Ajuste de minuto***t080 min59 min0 min
Relógio - Ajuste de data***t451311
Relógio - Ajuste do mês***t461121
Relógio - Ajuste do ano***t470990
Diversos
Atraso dos sinais de saída após o início de operaçõeso010 s600 s5 s
Sinal de entrada em DI1. Função:
0=não usado. 1=status em DI1. 2=função de porta com alarme quando aberto. 3=alarme
da porta quando aberto. 4=início de degelo (pressão de pulso). 5=interruptor principal
ext.. 6=operação noturna 7=mudar referência (ativar r40). 8=função de alarme quando fechado. 9=função de alarme quando aberto. 10=limpeza do expositor (pressão de pulso).
Endereço de rede (0=desligado)o0302400
Interruptor liga/desliga (mensagem de Pino de Serviço)
IMPORTANTE! o61 deve ser ajustado antes de o04
Código de acesso 1 (todos os ajustes)o0501000
Indicador da versão do softwareo06
Exibir etapa = 0,5 (normal 0,1 no sensor Pt)o15noyesno
Tempo de retenção máx. após degelo coordenadoo160 min60 min20
Seleção de sinal para exibir visão. S4% (100%=S4, 0%=S3)o170%100%100%
Sinal de entrada em DI2. Função:
(0=não usado. 1=status em DI2. 2=função de porta com alarme quando aberto. 3=alarme
de porta quando aberto. 4=início de degelo (pressão de pulso). 5=interruptor principal
ext. 6=operação noturna 7=mudar referência (ativar r40). 8=função de alarme quando fechado. 9=função de alarme quando aberto. 10=limpeza do expositor (pressão de pulso).
Configuração da função de luz (relé 4)
1=LIGADO durante a operação diurna. 2=LIGADO / DESLIGADO via comunicação de
dados. 3=segue a função de DI quando DI estiver selecionado para função de porta ou
alarme da porta
Ativação do relé de luz (somente se o38=2)o39OFFONOFF
Tempo de aquecimento do trilho ligado durante operações diurnaso410%100%100
Tempo de aquecimento do trilho ligado durante operações noturnaso420%100%100
Intervalo de tempo de aquecimento do trilho (tempo ligado + tempo desligado)o436 min60 min10 min
Limpeza do expositor. 0= sem limpeza do expositor. 1= somente ventiladores. 2= todas
as saídas desligadas.
Seleção do diagrama EL. Consultar a página de visão geral 2*o61151
Transferir por download um conjunto de ajustes predeterminados. Consultar a próxima
página de visão geral.
Código de acesso 2 (acesso parcial)***o6401000
Salvar os ajustes atuais dos controladores na tecla de programação. Selecionar seu
próprio número.
Carregar um conjunto de ajustes da tecla programação (salvo anteriormente via função o65)o660250
Substituir os ajustes de fábrica dos controladores pelos ajustes atuaiso67OFFOnOFF
Serviço de manutenção
Os códigos de status são mostrados na página 5S0-S32
Temperatura medida com o sensor S5***u09
Status na entrada DI1. on/1=fechadou10
Temperatura medida com o sensor S3***u12
Status na operação noturna (ligado ou desligado) 1=fechado***u13
Temperatura medida com o sensor S4***u16
Temperatura do termostatou17
Ler a referência de regulagem presenteu28
Status na saída DI2. on/1=fechadou37
Temperatura mostrada no displayu56
Temperatura medida do termostato de alarmeu57
Status no relé de resfriamento**u58
Status no relé de ventilador**u59
Status no relé de degelo**u60
Status no relé de aquecimento do trilho**u61
Status no relé de alarme**u62
Status no relé de luz**u63
Status no relé do compressor 2 **u67
Status no relé do compressor ventilador**u71
*) Pode ser ajustado somente quando a regulagem estiver parada (r12=0)
**) Pode ser controlado manualmente, mas somente quando r12=-1
***) Com código de acesso 2 o acesso a esses menus será limitado
1. Pressione o botão superior até ser mostrado um parâmetro r01
2. Pressione o botão superior ou inferior e
localize o parâmetro que deseja alterar
3. Pressione o botão intermediário até o
valor de parâmetro ser mostrado
Ajustar temperatura
1. Pressione o botão intermediário até ser
mostrado o valor de temperatura
2. Pressione o botão superior ou inferior e
selecione o novo valor
3. Pressione o botão intermediário nova-
mente para concluir o ajuste.
Diodos emissores de luz (LED)
= Refrigeração
= Degelo
= Ventilador funcionando
Flashes rápidos em alarme
4. Pressione o botão superior ou inferior e
selecione o novo valor
5. Pressione o botão intermediário nova-
Lendo a temperatura no sensor de degelo
• Pressione brevemente o botão inferior
HACCP
Função HACCP está ativo
mente para congelar o valor.
Partida/parada manual de um degelo
Desativar relê de alarme / alarme de recebimento / consultar código de alarme
• Pressione brevemente o botão superior
• Pressione o botão inferior durante quatro
segundos.
(No entanto, não aplicação 4)
Consulte o registro de HACCP
1. Pressione o botão intermediário por
mais tempo até h01 aparecer.
2. Selecione o h01-h10 requerido
3. Veja o valor pressionando brevemente o
botão intermediário
Exibição do código de falhaExibição do código de alarmeExibição do código de status
E 1
Falhas no controlador
E 6
Falha no relógio em tempo real. Reinicializar
o relógio.
E 25
Erro do sensor em S3
E 26
Erro do sensor em S4
E 27
Erro do sensor em S5
A 1
Alarme de alta temperatura
A 2
Alarma de baixa temperatura
A 4
Alarme da porta
A 5
Informação. O parâmetro o16 expirou
A 15
Alarme. Sinal da entrada DI1
A 16
Alarme. Sinal da entrada DI2
A 45
Posição de espera (refrigeração parada via
r12 ou entrada DI)
A 59
Limpeza do expositor. Sinal da entrada DI1
ou DI2
A 60
Alarme de alta temperatura da função
HACCP
S0Regulagem
S 1Aguardando o fim do congelamento
coordenado
S 2Quando o compressor estiver operando
deve funcionar durante pelo menos x
minutos.
S 3Quando o compressor parar, deve permane-
cer parado durante pelo menos x minutos.
S 4O evaporador goteja e aguarda o tempo
esgotar
S 10Refrigeração parada pelo interruptor
principal.
S 11Refrigeração parada pelo termostato
S 14Sequência de degelo. Degelo em anda-
mento
S 15Sequência de degelo. Atraso do ventilador
— água adere ao evaporador
S 17A porta está aberta. Entrada DI está aberta
S 20Resfriamento de emergência
S 25Controle manual das saídas
S 29Limpeza do expositor
S 30Resfriamento forçado
S 32 Atraso de saídas durante início de opera-
ções
nãoA temperatura de degelo não pode ser
exibida. Há parada baseada no tempo
-d-Degelo em andamento / Primeiro resfriamento após degelo
PSSenha requerida. Configurar senha
Ajuste de fábrica
Se for necessário retornar aos valores dos ajustes de fábrica, pode ser feito desta maneira:
- Desativar a tensão de alimentação para o controlador
- Mantenha os dois botões pressionados ao mesmo tempo ao conectar novamente a tensão de alimentação