Danfoss 077B7 Installation guide

Installation guide
089
Service thermostats Type 077B7
Service thermostats 077B7099 - Ice-cream cabinets and freezers without signal
077R0703
°C
Rated 8 – 40 A
-8.5
-14
Off Warm Cold
Cut-in
-24
Cut-out
-32
Setting pos.
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 95 (Used as airsensor min. 2 x LS)
3
Service thermostats 077B7101 - Bottle and liquid coolers
°C
077R0703
°C
+8.5
+3
4
Off Warm Cold
Cut-in
-9.5
Cut-out
-18
Setting pos.
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 95 (Used as airsensor min. 2 x LS)
43
Service thermostats 077B7102 - Ice-cream cabinets and freezers without signal
°C
+12.5
+9.5
Off Warm Cold
Cut-in
+5
Cut-out
+1.5
Setting pos.
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 100 (Used as airsensor min. 2 x LS)
Імпортер:ТОВ з іі "Данфосс ТОВ" 04080, Київ 80, п/с 168, Україна
© Danfoss | Climate Solutions | 2021.09
-9.5
-15
Off Warm Cold
Cut-in
-18
Cut-out
-24.5
Setting pos.
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 95 (Used as airsensor min. 2 x LS)
4343
Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB
AN212686433325en-000102 | 1
Service thermostats 077B7103 - Refrigerators with push button defrost
Service thermostats 077B7104 - Refrigerators with automatic defrost
°C
+6
-4
-13
Off Warm
Defrost
Cut-in
Cut-out
Setting pos.
-11
-22
Cold
Length of capillary (mm): L = 1000 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 105 (Used as airsensor min. 2 x LS)
No
Name
43
Service thermostats 077B7105 - Commercial refrigerators
°C
+8.5
+3
Off Warm Cold
Cut-in
Cut-out
-9.5
-18 43
Setting pos.
°C
+3.5
-12.5
Off Warm Cold
Cut-in
Cut-out
-23
Setting pos.
Length of capillary (mm): L = 1000 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 100 (Used as airsensor min. 2 x LS)
6
3
Service thermostats 077B7108 - Bottle and liquid coolers
°C
+15.2
+9.0
Off Warm Cold
Cut-in
Cut-out
+8
+0.5
3 4
Setting pos.
4
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): S = 95 (Used as airsensor min. 2 x LS)
Service thermostats 077B7109 - Bottle and liquid coolers
°C
+10.5
+5
Off Warm Cold
© Danfoss | Climate Solutions | 2021.09
Cut-in
+3
Cut-out
-4.5
Setting pos.
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 85 (Used as airsensor min. 2 x LS)
Length of capillary (mm): L = 1200 +30/-0 Min. sensor length mounted on evaporator (mm): LS = 100 (Used as airsensor min. 2 x LS)
Service thermostats 077B7274 - Refrigerators with automatic defrost
°C
+4.5
-4
43
Off Warm Cold
Cut-in
Cut-out
-10.5
Setting pos.
Length of capillary (mm): L = 900 +30/-0 (Airsensor)
43
AN212686433325en-000102 | 2
Accessories for 077B7099 Accessories for 077B7100, 077B7101, 077B7102,
077B7105, 077B7108, 077B7109
Accessories For 077B7104Accessories for 077B7103
© Danfoss | Climate Solutions | 2021.09
AN212686433325en-000102 | 3
Accessories for 077B7274
The 077B….EBD, 077B….L EBD can be applied on systems with R290 and R600a as the working fluid. For countries where safety standards are not an indispensable part of the safety system Danfoss recommend the installer to get a third party approval of the system containing flammable refrigerant.
Note: All temperatures at 760 mm Hg
© Danfoss | Climate Solutions | 2021.09
AN212686433325en-000102 | 4