Daitsu DS-9UIDN, DS-12UIDN, DS-24UIDN, DS-18UIDN Owner's Manual

Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent or visit sat.eurofredgroup.com.
Split Air Conditioner
DS-9UIDN
DS-12UIDN DS-18UIDN DS-24UIDN
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervi­sion or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustaina­ble reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
R410A(R32/125: 50/50):
Content
Operation Notices
Precautions...........................................................................................................1
Parts Name...........................................................................................................6
ScreenOperation Guide
.......................................................................7
Emergency operation .........................................................................................11
Maintenance
Clean and Maintenance......................................................................................11
Malfunction
Malfunction analysis ...........................................................................................15
2087.5
Remote control operation
............
1
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket. Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric shock.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
2
Precautions
WARNING
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the remote controller may be broken.
When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.
3
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing the unit.
According to the local safety regulations, use qualified power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact
separation of at least 3mm in all poles should be connected in fixed wiring.
Including an circuit break with suitable capacity, please note the following table.Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
Don’t use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to electricity and safety.
4
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.
The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can’t be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected by a professional.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
5
Precautions
WARNING
For the air conditioner with plug, the plug should be reachable after finishing installation.
For the air conditioner without plug, an circuit break must be installed in the line.
If you need to relocate the air conditioner to another place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Indoor side DB/WB (°C) Outdoor side DB/WB (°C)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
NOTICE:
The operating temperature range (outdoor temperature) for cooling is -15ºC~43ºC; Heating temperature range for the model without electric heating belt for chassis is -15ºC~24ºC Heating temperature range for the model with electric heating belt for chassis is -20ºC~24ºC.
6
Parts Name
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
(Display content or position may be different from above graphics, please refer to actual products)
air inlet panel
lter
aux.button
horizontal louver air outlet
cooling
indicator
power
indicator
receiver
window
display
heating
indicator
temp.
indicator
drying
indicator
Indoor Unit
Introduction for buttons on remote controller
Buttons on remote controller
1 2
5
4
6 7
8
11 12
9
On/Off button
▲/ button
3
Fan button
Swing button
X-Fan button
Turbo button
Light button
10
Temp button
button
Timer button
Sleep button
Mode button
Send signal
Turbo mode
8 heating function Set temperature
Set time
TIMER ON /TIMER OFF
Child lock
Up & down swing
Set fan speed
Light function
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
I feel function
X-fan mode
health function ventilation operation
2
5 7
9
4
12
3
1
6 8
10
11
NOTICE:
“ ” This is a general remote controller. Some models have this function while some do not. Please refer to the actual models.
7
Swing button
5
Press this button to set up & down swing angle.
Sleep button
6
Introduction for buttons on remote controller
Note:
After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the signal icon " " on the display of remote controller will blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the corre-
sponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
▲ / button
4
Press / button to increase/decreaseset temperature. In AUTO mode, set temperature is not adjustable.
Fan button
3
This button is used for setting Fan Speed in the sequence that goes from AUTO,
, to , then back to Auto.
On/Off button
1
Press this button to turn on the unit. Press this button again to turn off the unit.
Mode button
2
Each time you press this button,a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN, and HEAT *, as the following:
AUTO COOL DRY FAN
HEAT
*
* Note: Only for models with heating function.
● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
When setting Timer On or Timer Off, press "▲" or " " button to adjust the time.
Under Cool, Heat or Dry mode, press this button to turn on Sleep function. Press this button again to cancel Sleep function. Under Fan and Auto modes, this function is unavailable.
8
Press this button to achieve the on and off of healthy and scavenging functions in
LCD displays " ". Press the button for the second time to start healthy and scavenging functions simultaneously; LCD displays " " and " ". Press this button for the third time to quit healthy and scavenging functions simultaneously. Press the button for the fourth t ime to start healthy function; LCD display " ". Press this button again to repeat the operation above.
Note:
Outdoor temperature display is not available for some models. At that time, indoor unit receives " " signal, while it displays indoor set temperature.
will change quickly if holding " " or " " button). Time setting range is 0.5~24hours. Press this button again to confirm timer setting and the characters of HOUR ON (OFF)will stop flashing.
If the characters are flashing but you haven’t press timer button,timer setting status will be quit after 5s.If timer is confirmer, press this button again to cancel timer.
Under ON status, press this button to set timer OFF; Under OFF status, press this button to set timer ON.
● Press this button once and the characters of HOUR ON (OFF) will flash to be
displayed. Meanwhile, press " " button or " " button to adjust timer setting (time
Press this button, you can see indoor set temperature, indoor ambient temperature
on indoor unit’s display. The setting on remote controller is selected circularly as below:
no display
Turbo button
Press this button to activate / deactivate the Turbo function.
Introduction for buttons on remote controller
Press this button in COOL or DRY mode to turn on X-fan function.
Press this button to
turn on the display's light and press this button again to turn
off the display's
light.
When this function is started up, indoor fan will still operate at low fan speed for a while after turning off the unit by remote controller.
Function introduction for combination buttons
Combination of " " and " " buttons: About lock
Press " " and " "
buttons simultaneously 3s to lock or unlock the keypad. If the remote
three times.
controller is locked, is displayed. In this case, pressing any button, blinks
▲ ▲
7
Temp button
8
10
9
12
11
Timer button
Light button
X-Fan button
button
● This function is applicable to partial of models.
9
Replacement of batteries in remote controller
Function introduction for combination buttons
Combination of "MODE" and " " buttons: About switch between Fahrenheit and centigrade
Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function.
At unit OFF, press "MODE" and " " buttons simultaneously to
switch between and .
Combination of "TEMP" and "TIMER" buttons:
About Energy-saving Function
Press "TEMP" and "TIMER" simultaneously in COOL mode to start e nergy-saving function.
(46 if Fahrenheit is adopted). Repeat the operation to quit the function.
Combination of "TEMP" and "TIMER" buttons:
About 8
Heating Function
Press "TEMP" and "
TIMER
" simultaneously in HEAT mode to start 8℃ Heating Function
Nixie tube on the remote controller displays " " and a selected temperature of "8".
WIFI Function
Press "MODE" and "TURBO" button simultaneously to turn on or turn off WIFI
remote controller; Long press "MODE" and "TURBO" buttons simultaneously for 10s, remote controller will send WIFI reset code and then the WIFI function will be
turned on. WIFI function is defaulted ON after energization of the remote controller.
function. When WIFI function is turned on, the " " icon will be displayed on
This function is only available for some models.
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
signal sender battery
Cover of battery box
remove
reinstall
10
12
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below:
As shown in the g. Open panel, press aux. button to turn on or turn off the air
conditioner. When the air conditioner is turned on, it will operate under auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button.
Clean and maintenance
WARNING:
■ Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.
13
Clean and maintenance
Clean lter
1
Open panel
Pull out the panel to a certain
angle as shown in the g.
3
Clean lter
● Use dust catcher or water to clean the filter.
● When the filter is very dirty, use the water (below 45ºC ) to clean it, and then put it in a shady and cool place to dry.
2
Remove lter
Remove the lter as indicated in the g.
4
Install lter
Install the lter and then close the
panel cover tightly.
WARNING
■ The filter should be cleaned every three months. If there is much dust in the operation environment, clean frequency can be increased.
■ After removing the filter, do not touch fins to avoid injury.
■ Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
14
Clean and maintenance
1. Check whether air inlets and air outlets are blocked.
2. Check whether air switch, plug and socket are in good condition.
3. Check whether filter is clean.
4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
1. Disconnect power supply.
2. Clean filter and indoor unit’s panel.
3. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or consultant service center for the correct disposal method.
NOTICE: Checking before use-season
NOTICE: Checking after use-season
15
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualied professionals.
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote con­troller has no action.
● Whether it’s interfered severely (such as static electricity,stable voltage)?
● Pull out the plug. Reinsert the plug after about 3 min, and then turn on the unit again.
● Whether remote controller is within the signal receiving range?
● Signal receiving range is 8m.
● Whether there are obstacles? ● Remove obstacles.
● Whether remote controller is pointing at the receiving window?
● Select proper angle and point the remote controller at the receiving window on indoor unit.
● Is sensitivity of remote controller low; fuzzy display and no display?
● Check the batteries. If the power of batteries is too low, please replace them.
● No display when operating remote controller?
● Check whether remote controller appears to be damaged. If yes, replace it.
● Fluorescent lamp in room? ● Take the remote controller close to indoor unit.
● Turn off the fluoresent lamp and then try it again.
No air emitted from indoor unit
● Air inlet or air outlet of indoor unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor temperature is reached to set temperature?
● After reaching to set temperature, indoor unit will stop blowing out air.
● Heating mode is turned on just now?
● In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
16
Malfunction analysis
Phenomenon Check items Solution
Air condi­tioner can’t operate
● Power failure? ● Wait until power recovery.
● Is plug loose? ● Reinsert the plug.
● Air switch trips off or fuse is burnt out?
● Ask professional to replace air switch or fuse.
● Wiring has malfunction? ● Ask professional to replace it.
● Unit has restarted immediately after stopping operation?
● Wait for 3 min, and then turn on the unit again.
● Whether the function setting for remote controller is correct?
● Reset the function.
Mist is emitted from indoor unit’s air outlet
● Indoor temperature and humidity is high?
● Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
Set tempera­ture can’t be adjusted
● Unit is operating under auto mode?
● Temperature can’t be adjusted under auto mode. Please switch the operation mode if you need to adjust temperature.
● Your required temperature exceeds the set temperature range?
● Set temperature range: 16ºC ~30ºC.
Cooling (heating) effect is not good.
● Voltage is too low? ● Wait until the voltage resumes normal.
● Filter is dirty? ● Clean the filter.
● Set temperature is in proper
range?
● Adjust temperature to proper range.
● Door and window are open? ● Close door and window.
17
Malfunction analysis
Phenomenon Check items Solution
Odours are emitted
● Whether there’s odour source, such as furniture and cigarette, etc.
● Eliminate the odour source.
● Clean the filter.
Air condition­er operates normally suddenly
● Whether there’s interference, such as thunder, wireless devices, etc.
● Disconnect power, put back power, and then turn on the unit again.
Outdoor unit has vapor
● Heating mode is turned on? ● During defrosting under heating mode, it may generate vapor, which is a normal phenomenon.
“Water ow­ing” noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.
Cracking noise
● Air conditioner is turned on or turned off just now?
● This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
18
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indictor on indoor unit will blink to display corresponding error code. Please refer to below list for identific ation of error code.
Error code
Indoor display
Error code Troubleshooting
Heating indicator ON 10s OFF 0.5s Means defrosting status. It’s the normal phenomenon. E5: overcurrent protection Power indicator blinks and E5 is displayed C5:Connector jumper malfunction Check if the connector jumper contacts the properly. If
replace the PCB, please take off the old for the new PCB.
F1:Indoor ambient temp. sensor malfunction
Check if indoor room temp. sensor is connected properly?
F2:Evaporator temp.sensor malfunction Check if indoor tube temp. sensor is connected properly? H6:PC motor (indoor fan) can’t run • Feedback terminal of PG motor hasn’t been connected
firmly.
The control end of PG motor hasn’t been connected firmly.
Fan blade hasn’t been installed correctly and it can’t run smoothly.
Motor hasn’t been installed correctly and tightly.
Motor has been damaged.
Control panel has been damaged.
U8:Malfunction of zero cross detection circuit for PG motor (indoor fan)
Control panel has been damaged.
Note:
If there’re other error codes, please contact qualied professionals for service.
WARNING
■ When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
●Power cord is overheating or damaged.
●There’s abnormal sound during operation.
●Circuit break trips off frequently.
●Air conditioner gives off burning smell.
●Indoor unit is leaking.
■ Do not repair or refit the air conditioner by yourself
■ If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Above indicator diagram is only for reference. Please refer to actual product for the actual indicator and position.
18
Installation dimension diagram
At least 250cm
At least 15cm
At least 300cm
Space to the ceiling
Space to the obstruction
At least 15cm
At least 15cm
Space to the wall
Space to the wall
19
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service center authorized and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so that their terminals receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.
Safety precautions for installing and relocating the unit
20
Tools for installation
1. There should be no obstruction near air inlet .
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't
increase noise and vibration.
6. The appliance must be installed 2.5m above oor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from uorescent lamp.
Selection of installation location
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
● Don't use unqualied power cord.
Basic requirement
Indoor unit
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources,
vapors, ammable or explosive gas
, or
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical
equipment).
3. The place near coast area.
4.
The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
21
Requirements for electric connection
Safety precaution
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualied power supply circuit and
air switch.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
6. Do not put through the power before nishing installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualied persons in order to avoid a hazard.
8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
1. The air conditioner is the rst class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in xed wiring.
22
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
Step three: open piping hole
Left
Wall
Φ70mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ70mm
Rear piping hole
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
18K:
24K:
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
07 09K:
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
12K:
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space to the
wall
above
150mm
Φ55mm
Rear piping hole
23
1. Aim the pipe joint at the corresponding bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.
2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.
cut off the hole
left right
1. The pipe can be led out in the direction of right, rear right, left or rear left.
left
rear left
right
rear right
Step four: outlet pipe
Installation of indoor unit
union nutpipe joint
pipe
Indoor
5-10
outdoor
Φ70
Φ55/
Note:
● Pay attention to dust prevention and take relevant safety measures when
opening the hole.
The plastic expansion particles are not provided and should be bought
locally.
24
nection pipe with insulating pipe, and then wrap it with tape.
Step six: install drain hose
insulating pipe
1. Connect the drain hose to the outlet pipe of
2. Bind the joint with tape.
outlet
pipe
drain hose
drain hose
tape
outlet pipe
drain hose
insulating pipe
Add insulating pipe in the indoor drain hose in order to prevent condensation.
The plastic expansion particles are
1. Open the panel, remove the screw on the wiring cover and then take down the cover.
wiring cover
screw
panel
Step seven: connect wire of indoor unit
4. Wrap the indoor pipe and joint of con-
Installation of indoor unit
torque wrench
open-end wrench
indoor pipe
pipe
union nut
Hex nut diameter Tightening torque (N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40 45~55
60~65 70~75
15~20
indoor unit.
Note:
not provided.
25
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Installation of indoor unit
Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw
with wire clip.
power connection wire
cable-cross hole
2. Make the power connection wire go through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
N(1) 2 32
black
Outdoor unit connection
yellow­green
blue brown
26
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit
gas pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
● The power cord and control wire can't be crossed or winding.
● The drain hose should be bound
at the bottom.
drain hose
band
connection pipe
indoor power cord
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
upper hook
lower hook of wall-mounting frame
27
Check after installation
Test operation
Items to be checked Possible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
(heating) capacity.
It may cause condensation and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
It may cause malfunction or damaging the parts.
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power cord follow the speci-
It may cause malfunction or damaging the parts.
Is there any obstruction in the air inlet
Is the inlet and outlet of piping hole been covered?
and outlet?
(heating) capacity.
The dust and sundries caused during installation are removed?
It may cause malfunction or damaging the parts.
The gas valve and liquid valve of connection pipe are open completely?
(heating) capacit
It may cause insufficient cooling (heating) capacity or waster eletricity.
y.
1. Preparation of test operation
The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
Loading...