Daikin VAM-FA series, VKM-GM series, VKM-G series Catalogues

HRV
Heat Reclaim Ventilation
VAM-FA Series
VKM-GM Series
VKM-G Series
contents
Table of Contents
p. 3
INTRODUCTION
GENERAL HRV FEATURES
Energy Efficiency Design Flexibility Clean Air
VKM FEATURES
Energy Efficiency Design Flexibility
LINE-UP
CONTROL SYSTEMS
Individual Control Systems Centralised Control Systems
SPECIFICATIONS
VAM-FA VKM-GM VKM-G
4
6
6 7
9
10
10 11
12
13
13 16
18
18 19 20
OPTIONS
21
p. 4
Daikin
Daikin has a worldwide reputation based on over 70 years’
experience in the successful manufacture of high quality air
conditioning equipment for industrial, commercial and
residential use.
Daikin Europe N.V.
introduction
Environmental Consciousness
Enhancing the present - safeguarding the future
Throughout the last 50 years or so the basic building blocks of life - air, water and the earth - have been systematically subjected to increasing levels of pollution with little regard to their potentially devastating effects on future generations.
Recently however, concern has grown regarding climate changes, acid rain, water and air pollution and the constant degradation of Earth’s natural resources. The very technology that created these problems is now being harnessed to halt and reverse them. Depletion of the ozone layer and global warming have been highlighted and are now being addressed. Government legislation prohibiting the use of toxic substances and the generation of pollutants has slowed down the destruction of the environment.
Daikin Europe is proud to have been pro active in this respect, closely following its Japanese parent in implementing policies that have often pre-empted official legislative codes and directives. As a result, a culture of “environmental management” has since 2001, played a key role in the company’s day to day activities and development strategies.
Top management commitment is reflected in the establishment of a number of action plans, which are now strictly observed and implemented throughout the Daikin Group.
p. 5
HRV helps create a high quality environment by interlocking with the air conditioning system
The Daikin HRV (Heat Reclaim Ventilation) recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also reduces the load on the air conditioning system and conserves energy.
In addition, the HRV interlocks with Daikin’s VRV system, Sky Air and other air conditioning systems and automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralised on the air conditioner remote control allowing total control over air conditioning and ventilation via a simple configuration.
The current line-up includes models with DX coil and/or humidifier - the DX coil helps prevent the direct impact of cold airflow upon personnel during the heating cycle and vice versa. High static pressure enhances design flexibility.
Components of Indoor Air Quality
Ventilation
Humidi-
fication
HRV
Airflow
New Features VKM unit
Humidifier
DX coil
High static pressure
Line-up
Air flow rate (m3/h) 150 250 350 500 650 800 1000 1500 2000
VAM-FA Ventilation
VKM-GM: Ventilation, DX coil & humidifier
VKM-G: Ventilation & DX coil
p. 6
general HRV features
II. General HRV (VAM+VKM)
Features
1
1. ENERGY EFFICIENCY
Over 30 % Size Reduction Use of the high efficiency paper (HEP) element and optimized design of the fan and airflow passages have resulted in matchless compactness without detriment to the 28% or so reduction in air conditioning load achieved by previous models. A reduction of up to 40mm in height allows the main unit to fit easily into limited spaces such as ceilings On average 28 % air conditioning load reduction (maximum 40 %):
- 20% by operating in total heat exchange mode (in comparison with normal ventilation fans)
- a further 6 % by auto-ventilation mode changeover switching
- a further 2 % by pre-cool, pre-heat control (reduces air conditioning load by not running the
HRV while air is still clean soon after the air conditioner is switched on.)
Note: the values mentioned above may vary according to weather and other environmental conditions at the location of the unit’s installation
Proprietary Developed HEP Element The heat exchange element uses a high efficiency paper (HEP) possessing superior moisture absorption and humidifying properties. The heat exchange unit speedily recovers heat contained in latent heat (vapour). The element is made of a material with flame resistant properties and is treated with an anti-moulding agent.
Operation of the heat exchanger element
Outdoor Indoor
30.6°C 62% RH
32°C 70% RH
Integrally-formed liner
SA
27.4°C 63% RH
RA
26°C 50% RH
Temperature and humidity
SA
Integrally-
formed liner
RA
design flexibility
p. 7
Automatic Changeover to Efficient Operation Patterns Operation automatically switches to the optimum pattern to suit prevailing conditions
Cooling In between (bypass ventilation) Heating
Exhaust fan Damper
Heat exchanger element (heat recovery)
Heat exchanger element (heat recovery)
EA
OA
Air supply fan
2
2. DESIGN FLEXIBILITY
RA
SA
DX coil (cooling)
Automatic
changeover
EA
OA
RA
changeover
SA
Automatic
EA
OA
DX coil (heating)
Humidifying
Outdoor Operation Temperature down to -15°C
If the outdoor air suction temperature falls below -10°C, the unit switches to intermittent operation to prevent freezing of the heat exchanger element and dew condensation within the unit. Intermittent operation = a thermistor (standard equipment) within the unit detects the outdoor air temperature. Unit operation varies according to the detected temperature.
Slim Design
The slim design of the HRV unit enables it to be mounted in narrow ceiling voids and irregularly shaped spaces.
RA
SA
269mm VAM250FA
Installation under the floor of a small building Installation under a beam Installation in an irregular space
348mm
p. 8
design flexibility
Simple Design and Construction
The unit can be installed either horizontally or vertically in accordance with the conditions of the location. A 450mm square inspection hatch enables maintenance and heat exchange element replacement to be performed with ease.
Switch box
Access door
Maintenance cover
Quiet Operation
Sound pressure levels are remarkable low at 20.5dBA (VAM150FA)
dB(A) Perceived loudness Sound
0 Treshold of hearing - 20 Extremely soft Rustling leaves 40 Very soft Quiet room 60 Moderately loud Normal conversation 80 Very loud City traffic noise
100 Extremely loud Symphonic orchestra 120 Threshold of feeling Jet taking off
Daikin units