Daikin VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE Catalogues

...
Warning
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.
PCH0601
HE AT R ECL A IM V EN T IL A T ION
Combined Air Conditionin g and V entilation
for Energy Efficiency and Com fort
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment.
The air conditioners manufactured by Daikin I ndustries have received IS O 9001 certification for quality assurance.
Certificate Number.
JMI-0107 JQA-0495 JQA-1452
All Daikin Industries locations and subsidiaries in J apan have received environmental management system s tandard ISO 14001 certification.
Daikin Industries, Ltd. Domestic Group
Certificate Number. EC99J2044
Dealer
The specifications, designs, and information in this brochure are subject to change without notice.
About ISO 14001 ISO 14001 is the standard defined by the
International Organization for Standardization (I SO) relating to environmental management s ystems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of I SO 14001.
Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global/
c
All rights reserved Printed in Japan 05/06/003 Y.K.
Printed on 100% recycled paper with soy ink.
Daikin's HRV (Heat Reclaim Ventilation) recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy. In addition, the HRV is interlocked to Daikin's VRV system, SkyAir and other air conditioning systems and automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralized on the air conditioner remote controller allowing total control over air conditioning and ventilation with a simple configuration.
V A M -G J S e rie s R e le a s e d!
9 M od e ls t o C ho o s e F ro m !
Improved Enthalpy Efficiency
Improved Enthalpy Efficiency
Higher External Static Pressure
Higher External Static Pressure
Enhanced Energy Saving Functions
Enhanced Energy Saving Functions
1
2
For models: VAM150/250/350/650/800/1000/2000GJVE
1
For models: VAM150/350/500GJVE
2
Daikin air conditioner
Indoor unit
LCD remote controller for indoor unit
• Operating mode signal
• Filter cleaning signal
• Failure detection signal
Model Lineup
Model SeriesModel Series
• ON/OFF signal
• Cooling/Heating mode signal
• Set temperature signal
• Ventilation signal
• Humidifier ON/OFF signal
InterlockingInterlocking
HRV
Air flow rate (m3/h)
150 250 350 500 650 800 1000 1500 2000
VAM-GJ
F e a t u r e s o f D a ik in H R V
V A M -G J S e rie s
This series provides higher enthalpy efficiency, due to the greatly enhanced performance of the new ultra-thin film element. Furthermore, improved external static pressure offers more
2
flexibility for installation. Along with these three improvements, Daikin’s exclusive function —nighttime free cooling operation—contributes to energy conservation and more comfortable space.
Enthalpy efficiency dr astically impr oved!
Enthalpy efficiency dr astically impr oved!
Introduction of ultra-thin film element significantly increases enthalpy efficiency!
Enthalpy efficiency improved
Adoption of the ultra-thin film element leads to highly improved enthalpy efficiency.
Achieving higher enthalpy efficiency
VAM-FA
Previous model
VAM-GJ
Model
Ultra-thin film element
1
Outdoor air
1
1
Exhaust air
For models: VAM150/250/350/650/800/1000/2000GJVE
1
For models: VAM150/350/500GJVE
2
1
58
FA
66
GJ
58
FA
For models: VAM150/250/350/650/800/1000/2000GJVE
1
66
64
62
60
58
56
Cooling: Enthalpy efficiency (%)
Return air
Supply air
I
m
1
(For ultra high cooling operation)
64
GJ
61
GJ
650150 1000
61
FA
VAM650GJ
p
rov
e
(Air flow type)
d
Higher external static pressure
Higher external static pressure
External static pressure has been significantly increased by adopting a new type of fan.
High external static pressure design adopting efficient fan performance
2
2
I
m
pro
ved
Improvements to the fan, including the use of multi-arc blades and optimized fan sizes, help boost efficiency.
Comparison of external static pressure
(For ultra high operation)
High external static
pressure is realized
even below the
rated air flow!
300
250
VAM350GJVE
Exchange efficiency
90
80
70
40m
60
50 30m
(%)
!
200
External static pressure increased by 80 Pa
(for 60 Hz operation)
External static pressure (Pa)
150
VAM350FAVE
100
External static pressure increased by 71 Pa
50
(for 50 Hz operation)
0
100
200 400 600
300
Ener gy conser vation and comfor table air space
Ener gy conser vation and comfor table air space
500
Air flow rate
Nighttime free cooling operation
(m3/h)
20m
150 Pipe length
10m
For models: VAM150/350/500GJVE
2
50Hz,220–240V
60Hz,220V
VAM-GJ Model
VAM-FA Previous model
The partition sheet in the heat exchanger element has been significantly upgraded. It is approximately two-third thinner than the conventional type, resulting in a great improvement in moisture absorption!
Air conditioning sensible
heat load reduced by
No operation
Not operatingNot operating
Previous element (FA model) Ultra-thin film element
Moisture absorption is less effective due to the thickness of the partition sheets. It also limits the effective area that supply and exhaust air can be exposed to.
OutdoorIndoor
SA
RA (unclean indoor air)
3 4
Thickness of
the partition sheet
Exhaust air
Outdoor air (fresh air)
Due to the thinner film…
•Decreases the moisture resistance of the partition sheets drastically.
•Realizes more space for extra layers in the element, resulting in increased effective area that supply and exhaust air can be exposed to.
Moisture absorption increased by approx. 10%!
Sheet structure
Outdoor
SA
RA (unclean indoor air)
Indoor
Exhaust air
Outdoor air (fresh air)
High-humidity air
Supply air
Moisture exchange efficiency is greatly improved by using optimized thinner films and moisture-absorption materials in the element. Furthermore, miscellaneous gas barrier properties are maintained by decreasing the porosity in the moisture-absorption materials.
Thickness of
the partition sheet
Molecule of water
Miscellaneous gas CO2 molecule, etc.
Exhaust air
Precise, thin-film material
Low-humidity air
approx. 5%!
Nighttime free cooling operation is an energy-conserving function that works at night when air conditioners are off. By ventilating rooms containing office equipment that raises the room temperature, nighttime free cooling operation reduces the cooling load when air conditioners are turned on in the morning. It also alleviates feelings of discomfort in the morning caused by heat accumulated during the night.
•Nighttime free cooling operation only works to cool and if connected to Building Multi or VRV systems.
•Nighttime free cooling operation is set to “off” in the factory settings, so if you wish to use it, request your dealer to turn it on.
Indoor
unit
Generated
Heat generated by computers etc., is retained in the walls and ceiling.
Retained heat
heat
The air conditioning load is large so the temperature is not reduced quickly.
Exhaust
heat
Indoor
unit
UncomfortableUncomfortable
Nighttime free cooling operation
The indoor accumulated heat is discharged at night. This reduces the air conditioning load the next day thereby increasing efficiency.
Cold air
Indoor
unit
Exhaust
heat
Generated
heat
Heat is discharged. The load is small so the temperature is rapidly reduced
to a comfortable level.
*Interlocked operation with an air conditioner
Exhaust
heat
Indoor
unit
Comfortable!Comfortable!
Loading...