Daikin FTKN09JEVJU, FTKN12JEVJU, RKN09JEVJU, RKN12JEVJU, FTXN09JEVJU Engineeiring Data

...
EDUS041016
J-Series
- Cooling Only / Heat Pump ­SEER 13 Models
EDUS041016
Split-System
Room Air Conditioners
J-Series
1. Power Supply..........................................................................................3
2. Functions ................................................................................................4
3. Specifications..........................................................................................5
3.1 Cooling Only.............................................................................................5
3.2 Heat Pump ...............................................................................................6
4. Dimensions .............................................................................................7
4.1 Indoor Units..............................................................................................7
4.2 Outdoor Units...........................................................................................8
5. Wiring Diagrams .....................................................................................9
5.1 Indoor Units..............................................................................................9
5.2 Outdoor Units...........................................................................................9
6. Piping Diagrams....................................................................................10
6.1 Indoor Units............................................................................................10
6.2 Outdoor Units.........................................................................................11
7. Capacity Tables ....................................................................................12
7.1 Cooling Only...........................................................................................12
7.2 Heat Pump .............................................................................................14
7.3 Capacity correction factor by the length of refrigerant piping
(Reference) 18
8. Operation Limit......................................................................................19
9. Sound Level ..........................................................................................20
9.1 Measuring Location................................................................................20
9.2 Octave Band Level.................................................................................21
10.Electric Characteristics .........................................................................23
11.Installation Manual ................................................................................24
11.1 Indoor Units - Safety Considerions ........................................................24
11.2 Indoor Unit Installation Instructions........................................................26
11.3 Outdoor Units - Safety Considerions......................................................37
11.4 Outdoor Units Installation Instructions ...................................................39
12.Operation Manual .................................................................................49
The Single Split Duct-Free System
Cooling Only
FTKN09JEVJU FTKN12JEVJU
RKN09JEVJU RKN12JEVJU
Heat Pump
FTXN09JEVJU FTXN12JEVJU
RXN09JEVJU RXN12JEVJU
EDUS041016
2 Room Air Conditioners J-Series
12.1 Safety Considerations ............................................................................49
12.2 Operation Instructions ............................................................................52
13.Optional Accessories ............................................................................77
13.1 Option List ..............................................................................................77
13.2 <BRC944B2> Wired Remote Controller.................................................78
13.3 <KRP980B1> Interface Adaptor for Wired Remote Controller...............92
13.4 <KPW937A4> Air Direction Adjustment Grille........................................96
EDUS041016 Power Supply
1. Power Supply
Note:
Power Supply Intake ; Outdoor Unit
Indoor Units Outdoor Units Power Supply
The Single Split
Duct-Free System
FTKN09JEVJU RKN09JEVJU
1
, 208-230V, 60Hz
FTKN12JEVJU RKN12JEVJU
FTXN09JEVJU RXN09JEVJU
FTXN12JEVJU RXN12JEVJU
Functions EDUS041016
4 Room Air Conditioners J-Series
2. Functions
Category Functions
FTKN09/12JEVJU
RKN09/12JEVJU
FTXN09/12JEVJU
RXN09/12JEVJU
Category Functions
FTKN09/12JEVJU
RKN09/12JEVJU
FTXN09/12JEVJU
RXN09/12JEVJU
Basic Function
Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter
Operation Limit for Cooling (°FDB)
50~
114.8
50~
114.8
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°FWB) 5~68
Air-Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control 
Titanium Apatite Photocatalytic Air-Purifying Filter

Compressor Oval Scroll Compressor Air Filter (Prefilter) 
Swing Compressor  Wipe-clean Flat Panel 
Rotary Compressor Washable Grille
Reluctance DC Motor  Filter Cleaning Indicator
Comfortable Airflow
Power-Airflow Louver (Horizontal Blade)
 Good-Sleep Cooling Operation
Power-Airflow Dual Louvers Timer 24-Hour ON/OFF Timer 
Power-Airflow Diffuser NIGHT SET Mode 
Wide-Angle Fins (Vertical Blades) Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) 
Vertical Auto-Swing (Up and Down)  Self-Diagnosis (Digital, LED) Display 
Horizontal Auto-Swing (Right and Left) Wiring Error Check
3-D Airflow
Anti-Corrosion Treatment of Outdoor Heat Exchanger

COMFORT AIRFLOW Operation 
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
——
Comfort Control
Auto Fan Speed  Flexible Voltage Correspondence
Indoor Unit Quiet Operation  High Ceiling Application
NIGHT QUIET Mode (Automatic) Chargeless 32.8ft 32.8ft
Outdoor Unit Quiet Operation (Manual) Either Side Drain (Right or Left) 
INTELLIGENT EYE Operation Power Selection
Quick Warming Function
Remote Control
5-Rooms Centralized Controller (Option)
——
Hot-Start Function
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
——
Automatic Defrosting
Remote Control Adaptor (Normal Open Contact) (Option)
——
Operation Automatic Operation DIII-NET Compatible (Adaptor) (Option)
Program Dry Function Remote
Controller
Wireless 
Fan Only  Wired 
Lifestyle Convenience
New POWERFUL Operation (Non-Inverter)
——
Inverter POWERFUL Operation 
Priority-Room Setting
COOL / HEAT Mode Lock
HOME LEAVE Operation
ECONO Operation 
Indoor Unit ON/OFF Button 
Signal Receiving Sign 
Temperature Display
Another Room Operation
Note:  : Holding Functions
— : No Functions
EDUS041016 Specifications
3. Specifications
3.1 Cooling Only
The data are based on the conditions shown in the table below.
Models
60Hz 208-230V
Indoor Units FTKN09JEVJU FTKN12JEVJU Outdoor Units RKN09JEVJU RKN12JEVJU
Capacity Rated (Min.~Max.)
kW 2.49 (1.30~2.78) 2.93 (1.3~3.52)
Btu/h 8,500 (4,400~9,500) 10,000 (4,400~12,000)
kcal/h 2,140 (1,120~2,390) 2,520 (1,120~3,030) Running Current (Rated) A 4.6-4.1 4.8-4.4 Power Consumption Rated
(Min.~Max.)
W 795 (330~890) 945 (330~1,310) Power Factor % 83.1-84.3 94.7-93.4 COP (Rated) (Min.~Max.) W/W 3.13 (3.94~3.12) 3.10 (3.94~2.69) EER (Rated) (Min.~Max.)
Btu/h·W
10.69 (13.33~10.67) 10.58 (13.33~9.16)
Piping Connections
Liquid inch 1/4 1/4 Gas inch 3/8 3/8
Drain inch 5/8 5/8 Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes Max. Interunit Piping Length feet 49.2 49.2 Max. Interunit Height Difference feet 39.3 39.3 Chargeless feet 32.8 32.8 Amount of Additional Charge of Refrigerant oz/ft 0.22 0.22
Indoor Units FTKN09JEVJU FTKN12JEVJU
Front Panel Color White White
Airflow Rate
m³/min (cfm)
H 9.2 (325) 9.3 (328)
M 7.4 (261) 7.7 (272)
L 5.3 (187) 5.6 (198)
SL 4.0 (141) 4.4 (155)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof Running Current (Rated) A 0.20-0.18 0.20-0.18 Power Consumption (Rated) W 40 40 Power Factor % 96.2-96.6 96.2-96.6 Temperature Control Microcomputer Control Microcomputer Control Dimensions (H×W×D) inch 11-9/64×30-5/16×7-51/64 11-9/64×30-5/16×7-51/64 Packaged Dimensions (H×W×D) inch 10-17/64×33-7/32×13-15/32 10-17/64×33-7/32×13-15/32 Weight Lbs 16 16 Gross Weight Lbs 24 24 Operation Sound H/M/L/SL dBA 40 / 33 / 26 / 22 41 / 34 / 27 / 23 Sound Power dBA 56 57
Outdoor Units RKN09JEVJU RKN12JEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil
Type FVC50K FVC50K
Charge oz 12.5 12.5
Refrigerant
Type R-410A R-410A
Charge Lbs 2.20 2.20
Airflow Rate
m³/min (cfm)
H
29.0 (1,024) 29.0 (1,024)
Fan
Type Propeller Propeller
Motor Output W 59 59 Running Current (Rated) A 4.40-3.92 4.60-4.22 Power Consumption (Rated) W 755 905 Power Factor % 82.5-83.7 94.6-93.2 Starting Current A 4.6 4.8 Dimensions (H×W×D) inch 21-21/32×25-29/32×10-13/16 21-21/32×25-29/32×10-13/16 Packaged Dimensions (H×W×D) inch 23-5/16×30-23/64×13-45/64 23-5/16×30-23/64×13-45/64 Weight Lbs 66 66 Gross Weight Lbs 76 76 Operation Sound dBA 49 50 Sound Power dBA 63 64 Drawing No. 3D066714 3D066715
Cooling Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
25 ft
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
Specifications EDUS041016
6 Room Air Conditioners J-Series
3.2 Heat Pump
The data are based on the conditions shown in the table below.
Models
60Hz 208-230V
Indoor Units FTXN09JEVJU FTXN12JEVJU
Outdoor Units
RXN09JEVJU RXN12JEVJU
Cooling Heating Cooling Heating
Capacity Rated (Min.~Max.)
kW 2.49 (1.30~2.78) 2.93 (1.3~3.4) 2.93 (1.3~3.52) 3.52 (1.3~4.8)
Btu/h 8,500 (4,400~9,500) 10,000 (4,400~11,600) 10,000 (4,400~12,000) 12,000 (4,400~16,400)
kcal/h 2,140 (1,120~2,390) 2,520 (1,120~2,920) 2,520 (1,120~3,030) 3,030 (1,120~4,130) Running Current (Rated) A 4.6-4.1 4.6-4.2 4.8-4.4 5.4-4.9 Power Consumption Rated
(Min.~Max.)
W 795 (330~890) 865 (320~930) 945 (330~1,310) 1,050 (320~1,650) Power Factor % 83.1-84.3 90.4-89.5 94.7-93.4 93.5-93.2 COP (Rated) (Min.~Max.) W/W 3.13 (3.94~3.12) 3.39 (4.06~3.66) 3.10 (3.94~2.69) 3.35 (4.06~2.91) EER (Rated) (Min.~Max.)
Btu/h·W
10.69 (13.33~10.67) 11.56 (13.75~12.47) 10.58 (13.33~9.16) 11.43 (13.75~9.94)
Piping Connections
Liquid inch 1/4 1/4 Gas inch 3/8 3/8
Drain inch 5/8 5/8 Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes Max. Interunit Piping Length feet 49.2 49.2 Max. Interunit Height Difference feet 39.3 39.3 Chargeless feet 32.8 32.8 Amount of Additional Charge of
Refrigerant
oz/ft 0.22 0.22
Indoor Units FTXN09JEVJU FTXN12JEVJU
Front Panel Color White White
Airflow Rate m³/min (cfm)
H 9.2 (325) 9.7 (342) 9.3 (328) 10.1 (357)
M 7.4 (261) 8.1 (286) 7.7 (272) 8.4 (297)
L 5.3 (187) 6.4 (226) 5.6 (198) 6.7 (237)
SL 4.0 (141) 5.6 (198) 4.4 (155) 5.9 (208)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof Running Current (Rated) A 0.20-0.18 0.20-0.18 Power Consumption (Rated) W 40 40 Power Factor % 96.2-96.6 96.2-96.6 Temperature Control Microcomputer Control Microcomputer Control Dimensions (H×W×D) inch 11-9/64×30-5/16×7-51/64 11-9/64×30-5/16×7-51/64 Packaged Dimensions (H×W×D) inch 10-17/64×33-7/32×13-15/32 10-17/64×33-7/32×13-15/32 Weight Lbs 16 16 Gross Weight Lbs 24 24 Operation Sound H/M/L/SL dBA 40 / 33 / 26 / 22 40 / 34 / 28 / 25 41 / 34 / 27 / 23 41 / 35 / 29 / 26 Sound Power dBA 56 57
Outdoor Units RXN09JEVJU RXN12JEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil
Type FVC50K FVC50K
Charge oz 12.5 12.5
Refrigerant
Type R-410A R-410A
Charge Lbs 2.20 2.20 Airflow Rate m³/min (cfm) H 29.0 (1,024) 28.1 (992) 29.0 (1,024) 28.1 (992)
Fan
Type Propeller Propeller
Motor Output W 59 59 Running Current (Rated) A 4.40-3.92 4.40-4.02 4.60-4.22 5.20-4.72 Power Consumption (Rated) W 755 825 905 1,010 Power Factor % 82.5-83.7 90.1-89.2 94.6-93.2 93.4-93.0 Starting Current A 4.6 5.4 Dimensions (H×W×D) inch 21-21/32×25-29/32×10-13/16 21-21/32×25-29/32×10-13/16 Packaged Dimensions (H×W×D) inch 23-5/16×30-23/64×13-45/64 23-5/16×30-23/64×13-45/64 Weight Lbs 68 68 Gross Weight Lbs 78 78 Operation Sound dBA 49 50 50 51 Sound Power dBA 63 64 64 65 Drawing No. 3D066712 3D066713
Cooling Heating Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25 ft
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
EDUS041016 Dimensions
4. Dimensions
4.1 Indoor Units
FTKN09/12JEVJU
FTXN09/12JEVJU
AIRFLOW (INDOOR)
THE MARK () SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
RIGHTLEFT
1-3/16(30mm)MIN.
INCLUDING MOUNTING PLATE
(SPACE FOR
PERFORMANCE)
7-7/8(200mm)
1-15/16(50mm)MIN.
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
(SPACE FOR
FRONT PANEL FIXING SCREWS
REQUIRED SPACE
MAINTENANCE)
MAINTENANCE)
(INSIDE)
GENERAL RATING NAME PLATE
SIGNAL RECEIVER
TERMINAL BLOCK
OPERATION LAMP
WITH EARTH
TIMER LAMP
TERMINAL
F
F
O
O N
INDOOR UNIT ON/OFF SWITCH
(INSIDE)
11-9/64(283mm)
BOTTOM
ROOM TEMP. THERMISTOR
FLAPS
GAS PIPE φ3/8(φ9.5mm) CuT
(INSIDE)
DRAIN HOSE
(THE LENGTH OF PIPE OUTSIDE
(CONNECTING PART
THE UNIT : ABOUT 15-23/64(390mm))
I.D.
F
F
O
O N
LIQUID PIPE φ1/4(φ6.4mm) CuT
O.D.
φ
9/16(φ14mm)
φ
5/8(φ16mm)
(THE LENGTH OF PIPE OUTSIDE
THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
MODEL NAME
SIGNAL TRANSMITTER
15/64(6mm)
21-39/64(549mm)
5/8(16mm)
PLATE
3-31/32(101mm)
11/16(18mm)2-5/16(58mm)
BLADE ANGLE
6-49/64(172mm)
UP/DOWN (AUTOMATIC)
11-9/64(283mm)
1-5/8(41.3mm)
COOLING DRY FAN
45˚ 45˚45˚
2-9/64(54.5mm) 2-1/8(54mm)
1-5/8(41.3mm)
7-3/8(187mm)
WALL HOLE FOR EMBEDDED PIPING
RIGHT/LEFT (MANUAL)
φ
2-9/16(φ65mm) HOLE
WALL HOLE
φ
2-9/16(φ65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER
45˚
45˚
(ARC452A14)
3D065952B
AIRFLOW (INDOOR)
THE MARK () SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
RIGHT
LEFT
1-3/16(30mm)MIN.
INCLUDING MOUNTING PLATE
(SPACE FOR
PERFORMANCE)
7-7/8(200mm)
1-15/16(50mm)MIN.
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
(SPACE FOR
FRONT PANEL FIXING SCREWS
REQUIRED SPACE
MAINTENANCE)
MAINTENANCE)
(INSIDE)
GENERAL RATING NAME PLATE
SIGNAL RECEIVER
TERMINAL BLOCK
OPERATION LAMP
WITH EARTH
TIMER LAMP
TERMINAL
F
F
O
O N
INDOOR UNIT ON/OFF SWITCH
(INSIDE)
11-9/64(283mm)
BOTTOM
ROOM TEMP. THERMISTOR
FLAPS
GAS PIPE φ3/8(φ9.5mm) CuT
(INSIDE)
DRAIN HOSE
(THE LENGTH OF PIPE OUTSIDE
(CONNECTING PART
THE UNIT : ABOUT 15-23/64(390mm))
I.D.
F
F
O
O
N
LIQUID PIPE φ1/4(φ6.4mm) CuT
O.D.
φ
9/16(φ14mm)
φ
5/8(φ16mm)
(THE LENGTH OF PIPE OUTSIDE
THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
MODEL NAME
SIGNAL TRANSMITTER
15/64(6mm)
21-39/64(549mm)
5/8(16mm)
PLATE
3-31/32(101mm)
11/16(18mm)2-5/16(58mm)
BLADE ANGLE
6-49/64(172mm)
UP/DOWN (AUTOMATIC)
11-9/64(283mm)
1-5/8(41.3mm)
COOLING HEATING DRY
15˚
45˚
45˚
2-9/64(54.5mm) 2-1/8(54mm)
45˚
1-5/8(41.3mm)
7-3/8(187mm)
FAN
WALL HOLE FOR EMBEDDED PIPING
RIGHT/LEFT (MANUAL)
φ
2-9/16(φ65mm) HOLE
WALL HOLE
φ
2-9/16(φ65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER
45˚
45˚
45˚
(ARC452A12)
3D065951B
Dimensions EDUS041016
8 Room Air Conditioners J-Series
4.2 Outdoor Units
RKN09/12JEVJU, RXN09/12JEVJU
DRAIN OUTLET
4-HOLES FOR ANCHOR BOLTS
(I.D5/8 [φ15.9] HOSE FOR CONNECTION
(M8 OR M10)
WITH DRAIN JOINT [ OPTION ] )
18-1/2(470) 3-25/32(96)
1-9/16(40)
7/16(11)
14-29/32(379)
11-11/16(297)
OUTDOOR AIR THERMISTOR
BRAND NAME LABEL
MANUFACTURE'S LABEL
HANDLE
5/16(8)
5/16(8) 1-31/32(50)
10-13/16(275)
15/32(12) 25-29/32(658)
LIQUID STOP VALVE 1/4(φ6.4)CuT
SERVICE PORT
21-21/32(550)
6-5/8(168)
6-3/32(155)
WALL HEIGHT ON AIR OUTLET SIDE
MINIMUM SPACE FOR AIR PASSAGE
4-1/4(108)
=LESS THAN 47-3/16(1200)
IN CASE OF REMOVING
GAS ST
OP VALVE
STOP VALVE
3/8(φ9.5)CuT
5-7/8(150)
5-7/8(150)
1-15/16(50)1-15/16(50)1-15/16(50)
3-15/16(100)
1-15/16(50)
UNIT = INCH(mm)
3-15/16(100)
11-13/16(300)
3D065923A
EDUS041016 Wiring Diagrams
5. Wiring Diagrams
5.1 Indoor Units
FTKN09/12JEVJU, FTXN09/12JEVJU
5.2 Outdoor Units
RKN09/12JEVJU, RXN09/12JEVJU
PCB 2
PCB 1
S26S27
FIELD WIRING.
BLK
19
BLK
TRANSMISSION
BLK
GRN/YLW
LED1 H1P
CIRCUIT
BLK
BLK
3
FG
LED2 H2P
BLK
GRN
BLK
2
RECTIFIER
H3
BLK
+
RED
3
1
BLK
OUTDOOR
9
MR10
1
V1
H2
WHT
2
H1
CAUTION
BLK
S1W
1
NOTE THAT OPERATION WILL
F1U
RESTART AUTOMATICALLY IF
X1M
3.15A
THE MAIN POWER SUPPLY IS
+
R1T
TURNED OFF AND THEN BACK
IPM200
SIGNAL
ON AGAIN.
RECEIVER
11125 10S40312916
S32
S200
S6
INDOOR
BLK BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLKBLK
YLW
BLKBLKBLK
WIRELESS
BLU
BLK
RED
WHT
ORG
FG
REMOTE
F1U
1416
S601S602
CONTROLLER
H1~H3
MM
H1P~H2P
M1S
M1F
M1F
R2T
M1S PCB1~PCB3 R1T, R2T
NOTE)
S6~S602
S21
S1W
1.PCB3 SHOWS THE CASE OF X1M
OPTION CONNECTION.
PCB 3
OPTION
: FRAME GROUND : FUSE : HARNESS : PILOT LAMP : FAN MOTOR : SWING MOTOR : PRINTED CIRCUIT BOARD : THERMISTOR : CONNECTOR : OPERATION SWITCH : TERMINAL STRIP : PROTECTIVE EARTH
3D065939A
Piping Diagrams EDUS041016
10 Room Air Conditioners J-Series
6. Piping Diagrams
6.1 Indoor Units
FTKN09/12JEVJU FTXN09/12JEVJU
INDOOR UNIT
HEAT EXCHANGER
9/32CuT
3/16CuT
9/32CuT
THERMISTOR ON HEAT EXCH.
9/32CuT
9/32CuT
CROSS FLOW FAN
FIELD PIPING (1/4CuT)
M
FAN MOTOR
3/8CuT
FIELD PIPING (3/8CuT)
REFRIGERANT FLOW
COOLING
4D066315
INDOOR UNIT
HEAT EXCHANGER
9/32CuT
3/16CuT
9/32CuT
THERMISTOR ON HEAT EXCH.
9/32CuT
9/32CuT
CROSS FLOW FAN
FIELD PIPING (1/4CuT)
M
FAN MOTOR
3/8CuT
FIELD PIPING (3/8CuT)
REFRIGERANT FLOW
COOLING HEATING
4D066211
EDUS041016 Piping Diagrams
Room Air Conditioners J-Series 11
6.2 Outdoor Units
RKN09/12JEVJU
RXN09/12JEVJU
OUTDOOR UNIT
HEAT EXCHANGER
9/32CuT
9/32CuT
3/8CuT
CAPILLARY TUBE
3/16CuT
1/4CuT
1/4CuT
3/16CuT
THERMSTOR
MUFFLER
HEAT EXCHANGER
FAN
WITH
FILTER
MOTOR
M
PROPELLER FAN
1/4CuT
3/8CuT
STRAINER
FIELD PIPING
3/16CuT
(1/4CuT)
LIQUID STOP
3/8CuT
VALV E
1/4CuT
REFRIGERANT FLOW
MUFFLER MUFFLER
FIELD PIPING
3/8CuT
DISCHARGE PIPE
COOLING
COMPRESSOR
THERMISTOR
(3/8CuT)
GAS STOP VALV E
ACCUMULATOR
3D066384
OUTDOOR UNIT
OUTDOOR TEMPERATURE
HEAT EXCHANGER
9/32CuT
THERMISTOR
9/32CuT
3/8CuT
CAPILLARY
CHECK VALVE
TUBE 1
3/16CuT
1/4CuT1/4CuT
3/16CuT
MUFFLER
THERMISTOR
WITH
HEAT EXCHANGER
FAN
CAPILLARY
FILTER
MOTOR
TUBE 2
M
PROPELLER FAN
1/4CuT
3/8CuT
3/8CuT
FOUR WAY VALV E ON: HEATING
FIELD PIPING
3/16CuT
(1/4CuT)
LIQUID STOP
3/8CuT
VALV E
1/4CuT
REFRIGERANT FLOW
MUFFLER MUFFLER
FIELD PIPING
3/8CuT
DISCHARGE PIPE
COOLING
COMPRESSOR
THERMISTOR
(3/8CuT)
GAS STOP
HEATING
VALV E
ACCUMULATOR
3D066383
Capacity Tables EDUS041016
12 Room Air Conditioners J-Series
7. Capacity Tables
7.1 Cooling Only
FTKN09JEVJU + RKN09JEVJU (60Hz 208/230V)
3D066771
AFR 9.2
BF 0.23
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.32 1.85 0.58 2.32 1.85 0.65 2.32 1.85 0.73 2.27 1.83 0.75 2.20 1.80 0.79 2.09 1.74 0.84
16.0 22.0 2.67 1.93 0.61 2.55 1.88 0.67 2.43 1.83 0.73 2.39 1.81 0.75 2.32 1.77 0.79 2.20 1.72 0.85
18.0 25.0 2.78 2.03 0.62 2.66 1.99 0.68 2.55 1.94 0.73 2.50 1.92 0.76 2.43 1.89 0.79 2.32 1.84 0.85
19.4 26.7 2.84 2.16 0.62 2.72 2.11 0.68 2.61 2.06 0.74 2.56 2.04 0.76
2.49 2.01 0.80 2.37 1.97 0.85
22.0 30.0 3.01 2.08 0.62 2.89 2.04 0.68 2.78 2.00 0.74 2.73 1.98 0.77 2.66 1.96 0.80 2.55 1.92 0.86
24.0 32.0 3.12 2.03 0.63 3.01 1.99 0.69 2.89 1.96 0.75 2.85 1.94 0.77 2.78 1.92 0.80 2.66 1.88 0.86
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.92 5.43 0.58 7.92 5.43 0.65 7.92 5.43 0.73 7.76 5.30 0.75 7.52 5.11 0.79 7.13 4.80 0.79
60.8 71.6 9.10 6.05 0.61 8.70 5.71 0.67 8.31 5.39 0.73 8.15 5.27 0.75 7.91 5.08 0.79 7.52 4.79 0.80
64.4 77.0 9.49 6.09 0.62 9.10 5.78 0.68 8.70 5.47 0.73 8.54 5.35 0.76 8.30 5.17 0.79 7.91 4.89 0.80
67.0 80.0 9.69 6.18 0.62 9.29 5.86 0.68 8.90 5.56 0.74 8.74 5.45 0.76
8.50 5.27 0.80 8.10 5.00 0.80
71.6 86.0 10.27 5.93 0.62 9.88 5.64 0.68 9.48 5.36 0.74 9.32 5.26 0.77 9.09 5.10 0.80 8.69 4.84 0.81
75.289.610.675.720.6310.275.450.699.875.190.759.725.090.779.484.940.809.084.700.81
Symbols Note:
AFR : Airflow rate (m3/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
5. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25 ft Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
EDUS041016 Capacity Tables
Room Air Conditioners J-Series 13
FTKN12JEVJU + RKN12JEVJU (60Hz 208/230V)
3D066772
AFR 9.3
BF 0.26
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.28 1.82 0.63 2.28 1.82 0.71 2.28 1.82 0.80 2.28 1.82 0.84 2.28 1.82 0.89 2.28 1.82 0.98
16.0 22.0 3.05 2.10 0.72 3.00 2.08 0.80 2.86 2.01 0.87 2.81 1.99 0.90 2.73 1.95 0.94 2.59 1.89 1.01
18.0 25.0 3.27 2.24 0.73 3.14 2.17 0.80 3.00 2.11 0.87 2.94 2.09 0.90 2.86 2.06 0.94 2.73 2.00 1.01
19.4 26.7 3.34 2.35 0.74 3.20 2.29 0.81 3.07 2.23 0.88 3.01 2.21 0.90
2.93 2.18 0.95 2.79 2.12 1.01
22.0 30.0 3.54 2.26 0.74 3.41 2.21 0.81 3.27 2.16 0.88 3.21 2.14 0.91 3.13 2.11 0.95 3.00 2.06 1.02
24.0 32.0 3.68 2.20 0.75 3.54 2.16 0.82 3.40 2.11 0.89 3.35 2.09 0.91 3.27 2.06 0.96 3.13 2.02 1.03
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.78 5.33 0.63 7.78 5.33 0.71 7.78 5.33 0.80 7.78 5.33 0.84 7.78 5.33 0.89 7.78 5.33 0.92
60.871.610.417.290.7210.247.130.809.776.690.879.596.510.909.316.260.948.845.860.95
64.4 77.0 11.17 7.64 0.73 10.70 7.20 0.80 10.24 6.77 0.87 10.05 6.60 0.90 9.77 6.36 0.94 9.30 5.97 0.95
67.0 80.0 11.40 7.72 0.74 10.93 7.28 0.81 10.47 6.86 0.88 10.28 6.70 0.90
10.00 6.46 0.95 9.53 6.08 0.95
71.6 86.0 12.09 7.45 0.74 11.62 7.04 0.81 11.16 6.65 0.88 10.97 6.50 0.91 10.69 6.28 0.95 10.23 5.92 0.96
75.2 89.6 12.55 7.20 0.75 12.08 6.82 0.82 11.62 6.45 0.89 11.43 6.31 0.91 11.15 6.10 0.96 10.69 5.76 0.96
Symbols Note:
AFR : Airflow rate (m3/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
5. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25 ft Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Capacity Tables EDUS041016
14 Room Air Conditioners J-Series
7.2 Heat Pump
FTXN09JEVJU + RXN09JEVJU (60Hz 208/230V)
Cooling
Heating
AFR 9.2
BF 0.23
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.32 1.85 0.58 2.32 1.85 0.65 2.32 1.85 0.73 2.27 1.83 0.75 2.20 1.80 0.79 2.09 1.74 0.84
16.0 22.0 2.67 1.93 0.61 2.55 1.88 0.67 2.43 1.83 0.73 2.39 1.81 0.75 2.32 1.77 0.79 2.20 1.72 0.85
18.0 25.0 2.78 2.03 0.62 2.66 1.99 0.68 2.55 1.94 0.73 2.50 1.92 0.76 2.43 1.89 0.79 2.32 1.84 0.85
19.4 26.7 2.84 2.16 0.62 2.72 2.11 0.68 2.61 2.06 0.74 2.56 2.04 0.76
2.49 2.01 0.80 2.37 1.97 0.85
22.0 30.0 3.01 2.08 0.62 2.89 2.04 0.68 2.78 2.00 0.74 2.73 1.98 0.77 2.66 1.96 0.80 2.55 1.92 0.86
24.0 32.0 3.12 2.03 0.63 3.01 1.99 0.69 2.89 1.96 0.75 2.85 1.94 0.77 2.78 1.92 0.80 2.66 1.88 0.86
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.92 5.43 0.58 7.92 5.43 0.65 7.92 5.43 0.73 7.76 5.30 0.75 7.52 5.11 0.79 7.13 4.80 0.79
60.8 71.6 9.10 6.05 0.61 8.70 5.71 0.67 8.31 5.39 0.73 8.15 5.27 0.75 7.91 5.08 0.79 7.52 4.79 0.80
64.4 77.0 9.49 6.09 0.62 9.10 5.78 0.68 8.70 5.47 0.73 8.54 5.35 0.76 8.30 5.17 0.79 7.91 4.89 0.80
67.0 80.0 9.69 6.18 0.62 9.29 5.86 0.68 8.90 5.56 0.74 8.74 5.45 0.76
8.50 5.27 0.80 8.10 5.00 0.80
71.6 86.0 10.27 5.93 0.62 9.88 5.64 0.68 9.48 5.36 0.74 9.32 5.26 0.77 9.09 5.10 0.80 8.69 4.84 0.81
75.289.610.675.720.6310.275.450.699.875.190.759.725.090.779.484.940.809.084.700.81
AFR 9.7
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15.0 –10.0 –5.0 0 6.0 10.0
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.40 0.56 1.68 0.59 1.96 0.61 2.63 0.80 3.03 0.85 3.30 0.87
21.1 1.31 0.57 1.59 0.60 1.87 0.63 2.53 0.82
2.93 0.87 3.19 0.89
22.0 1.27 0.58 1.56 0.61 1.84 0.64 2.49 0.83 2.89 0.87 3.15 0.90
24.0 1.24 0.58 1.52 0.61 1.80 0.64 2.45 0.84 2.85 0.88 3.11 0.91
25.0 1.22 0.59 1.50 0.62 1.79 0.64 2.43 0.84 2.83 0.88 3.09 0.91
27.0 1.19 0.59 1.47 0.62 1.75 0.65 2.39 0.85 2.79 0.89 3.05 0.92
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5.0 14.0 23.0 32.0 43.0 50.0
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 4.76 0.56 5.72 0.59 6.68 0.61 8.99 0.80 10.35 0.85 11.25 0.87
70.0 4.47 0.57 5.43 0.60 6.39 0.63 8.64 0.82
10.00 0.87 10.90 0.89
71.6 4.35 0.58 5.31 0.61 6.27 0.64 8.51 0.83 9.86 0.87 10.77 0.90
75.2 4.23 0.58 5.19 0.61 6.15 0.64 8.37 0.84 9.72 0.88 10.63 0.91
77.0 4.18 0.59 5.14 0.62 6.10 0.64 8.30 0.84 9.65 0.88 10.56 0.91
80.6 4.06 0.59 5.02 0.62 5.98 0.65 8.16 0.85 9.52 0.89 10.42 0.92
EDUS041016 Capacity Tables
Room Air Conditioners J-Series 15
3D066769
Symbols Note:
AFR : Airflow rate (m3/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
5. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25 ft Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Capacity Tables EDUS041016
16 Room Air Conditioners J-Series
FTXN12JEVJU + RXN12JEVJU (60Hz 208/230V)
Cooling
Heating
AFR 9.3
BF 0.26
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.28 1.82 0.63 2.28 1.82 0.71 2.28 1.82 0.80 2.28 1.82 0.84 2.28 1.82 0.89 2.28 1.82 0.98
16.0 22.0 3.05 2.10 0.72 3.00 2.08 0.80 2.86 2.01 0.87 2.81 1.99 0.90 2.73 1.95 0.94 2.59 1.89 1.01
18.0 25.0 3.27 2.24 0.73 3.14 2.17 0.80 3.00 2.11 0.87 2.94 2.09 0.90 2.86 2.06 0.94 2.73 2.00 1.01
19.4 26.7 3.34 2.35 0.74 3.20 2.29 0.81 3.07 2.23 0.88 3.01 2.21 0.90
2.93 2.18 0.95 2.79 2.12 1.01
22.0 30.0 3.54 2.26 0.74 3.41 2.21 0.81 3.27 2.16 0.88 3.21 2.14 0.91 3.13 2.11 0.95 3.00 2.06 1.02
24.0 32.0 3.68 2.20 0.75 3.54 2.16 0.82 3.40 2.11 0.89 3.35 2.09 0.91 3.27 2.06 0.96 3.13 2.02 1.03
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.78 5.33 0.63 7.78 5.33 0.71 7.78 5.33 0.80 7.78 5.33 0.84 7.78 5.33 0.89 7.78 5.33 0.92
60.871.610.417.290.7210.247.130.809.776.690.879.596.510.909.316.260.948.845.860.95
64.4 77.0 11.17 7.64 0.73 10.70 7.20 0.80 10.24 6.77 0.87 10.05 6.60 0.90 9.77 6.36 0.94 9.30 5.97 0.95
67.0 80.0 11.40 7.72 0.74 10.93 7.28 0.81 10.47 6.86 0.88 10.28 6.70 0.90
10.00 6.46 0.95 9.53 6.08 0.95
71.6 86.0 12.09 7.45 0.74 11.62 7.04 0.81 11.16 6.65 0.88 10.97 6.50 0.91 10.69 6.28 0.95 10.23 5.92 0.96
75.2 89.6 12.55 7.20 0.75 12.08 6.82 0.82 11.62 6.45 0.89 11.43 6.31 0.91 11.15 6.10 0.96 10.69 5.76 0.96
AFR 10.1
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15.0 –10.0 –5.0 0 6.0 10.0
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.68 0.68 2.01 0.71 2.35 0.74 3.16 0.97 3.64 1.03 3.96 1.06
21.1 1.57 0.69 1.91 0.73 2.25 0.76 3.04 1.00
3.52 1.05 3.84 1.08
22.0 1.53 0.70 1.87 0.74 2.21 0.77 2.99 1.01 3.47 1.06 3.79 1.09
24.0 1.49 0.71 1.83 0.74 2.17 0.78 2.95 1.02 3.42 1.07 3.74 1.10
25.0 1.47 0.71 1.81 0.75 2.15 0.78 2.92 1.02 3.40 1.07 3.72 1.11
27.0 1.43 0.72 1.77 0.76 2.10 0.79 2.87 1.03 3.35 1.08 3.67 1.12
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5.0 14.0 23.0 32.0 43.0 50.0
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 5.71 0.68 6.87 0.71 8.02 0.74 10.79 0.97 12.41 1.03 13.50 1.06
70.0 5.36 0.69 6.51 0.73 7.67 0.76 10.37 1.00
12.00 1.05 13.08 1.08
71.6 5.22 0.70 6.37 0.74 7.53 0.77 10.21 1.01 11.83 1.06 12.92 1.09
75.2 5.08 0.71 6.23 0.74 7.38 0.78 10.04 1.02 11.67 1.07 12.75 1.10
77.0 5.01 0.71 6.16 0.75 7.31 0.78 9.96 1.02 11.59 1.07 12.67 1.11
80.6 4.87 0.72 6.02 0.76 7.17 0.79 9.79 1.03 11.42 1.08 12.50 1.12
EDUS041016 Capacity Tables
Room Air Conditioners J-Series 17
3D066770
Symbols Note:
AFR : Airflow rate (m3/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
5. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25 ft Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Capacity Tables EDUS041016
18 Room Air Conditioners J-Series
7.3 Capacity correction factor by the length of refrigerant piping (Reference)
The cooling and the heating capacity of the unit has to be corrected in accordance with the length of refrigerant piping. (The
distance between the indoor unit and the outdoor unit)
Note:
The graph shows the factor when additional refrigerant of the proper quantity is charged.
<— line : cooling capacity> <--- line : heating capacity>
Capacity correction factor
1
16.4 32.8 49.2
0.9
0.8
R-410A (09/12 class)
Piping length (ft)
(R11493)
Range of the refrigerant additional charge
EDUS041016 Operation Limit
Room Air Conditioners J-Series 19
8. Operation Limit
RKN09/12JEVJU
RXN09/12JEVJU
122
114.8
104
86
68
Pull-down period
Continuous operation
Outdoor temp. (˚FDB)
50
32
866857.250 73.4 82.4
Indoor temp. (˚FWB)
Notes:
The graphs are based on the following conditions.
• Equivalent piping length 25ft
• Level difference 0ft
• Air flow rate High
4D066173A
Heating
Cooling
68
122
114.8 59
104
50
86
41
32
68
Pull-down period
Outdoor temp. (˚FWB)
23
Continuous operation
Outdoor temp. (˚FDB)
50
Continuous operation
14
32
5
82.468 8673.457.250 (5˚FDB)
Indoor temp. (˚FWB)
50 8668
Notes:
Indoor temp. (˚FDB)
The graphs are based on the following conditions.
• Equivalent piping length 25ft
• Level difference 0ft
• Air flow rate High
3D066174A
Sound Level EDUS041016
20 Room Air Conditioners J-Series
9. Sound Level
9.1 Measuring Location
Note:
1. Operation sound is measured in an anechoic chamber.
2. The data are based on the conditions shown in the table below.
Indoor Unit
The Single Split Duct-Free System
Outdoor Unit
3.3 ft
2.6 ft
(R5162)
3.3 ft
(R4796)
Cooling Heating Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25 ft
EDUS041016 Sound Level
Room Air Conditioners J-Series 21
9.2 Octave Band Level
9.2.1 Indoor Units
FTKN09JEVJU FTKN12JEVJU
FTXN09JEVJU
FTXN12JEVJU
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
60
50
10
20
40
30
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
NC-10
NC-20
NC-30
NC-40
NC-50
COOLING
2640
(L)
208/230V
60Hz
(H)
208/230V
60Hz
Cooling
60Hz 208/230V(L)
60Hz 208/230V(H)
STANDARD EXTERNAL STATIC PRESSURE
208/230V 60Hz
4D066746
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
60
50
10
20
40
30
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
NC-50
NC-40
NC-30
NC-20
NC-10
60Hz 60Hz
208/230V 208/230V
(H) (L)
41 27
208/230V 60Hz
STANDARD EXTERNAL STATIC PRESSURE
60Hz 208/230V(H)
60Hz 208/230V(L)
Cooling
COOLING
4D066747
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
60
50
10
20
40
30
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
60
50
10
20
40
30
63
OCTAVE BAND CENTER FREQUENCY (Hz
)
125 250 500 1000 2000 4000 8000
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
COOLING HEATING
NC-10
NC-20
NC-30
NC-40
NC-50
NC-10
NC-20
NC-30
NC-40
NC-50
2640
(L)
208/230V
60Hz
(H)
208/230V
60Hz
60Hz 208/230V(L)
60Hz 208/230V(H)
208/230V 60Hz
Cooling
STANDARD EXTERNAL STATIC PRESSURE
Heating
60Hz 208/230V(L)
60Hz 208/230V(H)
STANDARD EXTERNAL STATIC PRESSURE
208/230V 60Hz
2840
(L)
208/230V
60Hz
(H)
208/230V
60Hz
3D066744
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
60-
50
10
20
40
30
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
60
50
10
20
40
30
63
OCTAVE BAND CENTER FREQUENCY (Hz
)
125 250 500 1000 2000 4000 8000
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
COOLING HEATING
NC-10
NC-20
NC-30
NC-40
NC-50
NC-10
NC-20
NC-30
NC-40
NC-50
2741
(L)
208/230V
60Hz
(H)
208/230V
60Hz
208/230V 60Hz
Cooling
60Hz 208/230V(L
)
60Hz 208/230V(H
)
STANDARD EXTERNAL STATIC PRESSURE
2941
(L)
208/230V
60Hz
(H)
208/230V
60Hz
Heating
60Hz 208/230V(L)
60Hz 208/230V(H)
STANDARD EXTERNAL STATIC PRESSURE
208/230V 60Hz
3D066745
Sound Level EDUS041016
22 Room Air Conditioners J-Series
9.2.2 Outdoor Units
RKN09JEVJU RKN12JEVJU
RXN09JEVJU
RXN12JEVJU
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
NC-20
NC-30
NC-40
NC-50
NC-60
49
230V(H
)
60Hz
Cooling
60Hz 230V
230V 60Hz
COOLING
4D066752
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
NC-20
NC-30
NC-40
NC-50
NC-60
50
230V(H)
60Hz
Cooling
60Hz 230V
230V 60Hz
COOLING
4D066753
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
70
60
20
30
50
40
63
OCTAVE BAND CENTER FREQUENCY (Hz
)
125 250 500 1000 2000 4000 8000
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
COOLING HEATING
230V 60Hz
49
230V(H)
60Hz
Cooling
60Hz 230V
230V 60Hz
50
230V(H)
60Hz
Heating
60Hz 230V
NC-20
NC-30
NC-40
NC-50
NC-60
NC-20
NC-30
NC-40
NC-50
NC-60
3D066750
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
63 125
OCTAVE BAND CENTER FREQUENCY (Hz
)
250 500 1000 2000 4000 8000
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
70
60
20
30
50
40
63
OCTAVE BAND CENTER FREQUENCY (Hz
)
125 250 500 1000 2000 4000 8000
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
μ
bar
)
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS NOISE
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL ( dB )
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
COOLING HEATING
NC-20
NC-30
NC-40
NC-50
NC-60
NC-20
NC-30
NC-40
NC-50
NC-60
230V 60Hz
50
230V(H)
60Hz
Cooling
60Hz 230V
230V 60Hz
51
230V(H)
60Hz
Heating
60Hz 230V
3D066751
EDUS041016 Electric Characteristics
Room Air Conditioners J-Series 23
10.Electric Characteristics
3D066179C
Representative Unit Combination Power Supply COMP OFM IFM
Indoor Unit Outdoor Unit Hz-Volts Voltage Range MCA MOP RLA W FLA W FLA
FTKN09JEVJU RKN09JEVJU
60-208
MAX. 60Hz 253V
MIN. 60Hz 187V
8.3 15
6.7 59
0.29 40
0.20
60-230 6.1 0.26 0.18
FTKN12JEVJU RKN12JEVJU
60-208
MAX. 60Hz 253V
MIN. 60Hz 187V
8.3 15
6.7 59
0.29 40
0.20
60-230 6.1 0.26 0.18
FTXN09JEVJU RXN09JEVJU
60-208
MAX. 60Hz 253V
MIN. 60Hz 187V
8.3 15
6.7 59
0.29 40
0.20
60-230 6.1 0.26 0.18
FTXN12JEVJU RXN12JEVJU
60-208
MAX. 60Hz 253V
MIN. 60Hz 187V
8.3 15
6.7 59
0.29 40
0.20
60-230 6.1 0.26 0.18
Symbols: Note:
MCA : MIN. CIRCUIT AMPS (A) 1. Maximum allowable voltage variation between phases is 2%.
2. Select wire size based on the larger value of MCA.
3. Instead of fuse, use circuit breaker.
4. Be sure to install an ground leak detector. (One that can handle higher harmonics.) (This unit uses an inverter, which means that it must be use a ground leak detector capable handling high harmonics in order to prevent malfunctioning of the ground leak detector itself.)
MOP : MAX. OVERCURRENT PROTECTION (A)
RLA : RATED LOAD AMPS (A)
OFM : OUTDOOR FAN MOTOR
IFM : INDOOR FAN MOTOR
FLA : FULL LOAD AMPS (A)
W : FAN MOTOR RATED OUTPUT (W)
Installation Manual EDUS041016
24 Room Air Conditioners J-Series
11.Installation Manual
11.1 Indoor Units - Safety Considerions
Read these SAFETY CONSIDERATIONS for Installation carefully before installing air conditioning equipment. After completing the installation, make sure that the unit operates properly during the startup operation.
Instruct the customer on how to operate and maintain the unit. Inform customers that they should store this Installation Manual with the Operation Manual for future reference.
Always use a licensed installer or contractor to install this product. Improper installation can result in water or refrigerant leakage, electrical shock, fire, or explosion.
Meanings of DANGER, WARNING, CAUTION, and NOTE Symbols:
DANGER .............. Indicates an imminently hazardous
situation which, if not avoided, will result in death or serious injury.
WARNING ............ Indicates a potentially hazardous
situation which, if not avoided, could result in death or serious injury.
CAUTION ............. Indicates a potentially hazardous
situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
NOTE .................. Indicates situations that may result in
equipment or property-damage accidents only.
• Refrigerant gas is heavier than air and replaces oxygen. A massive leak can lead to oxygen depletion, especially in basements, and an asphyxiation hazard could occur leading to serious injury or death.
• Do not ground units to water pipes, gas pipes, telephone wires, or lightning rods as incomplete grounding can cause a severe shock hazard resulting in severe injury or death. Additionally, grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death.
• If refrigerant gas leaks during installation, ventilate the area immediately. Refrigerant gas may produce toxic gas if it comes into contact with fire. Exposure to this gas could cause severe injury or death.
• After completing the installation work, check that the refrigerant gas does not leak throughout the system.
• Do not install unit in an area where flammable materials are present due to risk of explosions that can cause serious injury or death.
• Safely dispose all packing and transportation materials in accordance with federal/state/local laws or ordinances. Packing materials such as nails and other metal or wood parts, including plastic packing
materials used for transportation may cause injuries or death by suffocation.
• Only qualified personnel must carry out the installation work. Installation must be done in accordance with this installation manual. Improper installation may result in water leakage, electric shock, or fire.
• When installing the unit in a small room, take measures to keep the refrigerant concentration from exceeding allowable safety limits. Excessive refrigerant leaks, in the event of an accident in a closed ambient space, can lead to oxygen deficiency.
• Use only specified accessories and parts for installation work. Failure to use specified parts may result in water leakage, electric shocks, fire, or the unit falling.
• Install the air conditioner on a foundation strong enough that it can withstand the weight of the unit. A foundation of insufficient strength may result in the unit falling and causing injuries.
• Take into account strong winds, typhoons, or earthquakes when installing. Improper installation may result in the unit falling and causing accidents.
• Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local. state, and national regulations. An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire.
• Make sure that all wiring is secured, that specified wires are used, and that no external forces act on the terminal connections or wires. Improper connections or installation may result in fire.
• When wiring, position the wires so that the terminal box lid can be securely fastened. Improper positioning of the terminal box lid may result in electric shocks, fire, or the terminals overheating.
• Before touching electrical parts, turn off the unit.
• It is recommended to install a ground fault circuit interrupter if one is not already available. This helps prevent electrical shocks or fire.
• Securely fasten the outside unit terminal cover (panel). If the terminal cover/panel is not installed properly, dust or water may enter the outside unit causing fire or electric shock.
• When installing or relocating the system, keep the refrigerant circuit free from substances other than the specified refrigerant (R-410A) such as air. Any presence of air or other foreign substance in the refrigerant circuit can cause an abnormal pressure rise or rupture, resulting in injury.
EDUS041016 Installation Manual
Room Air Conditioners J-Series 25
• Do not change the setting of the protection devices. If the pressure switch, thermal switch, or other protection device is shorted and operated forcibly, or parts other than those specified by Daikin are used, fire or explosion may occur.
• Do not touch the switch with wet fingers. Touching a switch with wet fingers can cause electric shock.
• Do not allow children to play on or around the unit to prevent injury.
• Do not touch the refrigerant pipes during and immediately after operation as the refrigerant pipes may be hot or cold, depending on the condition of the refrigerant flowing through the refrigerant piping, compressor, and other refrigerant cycle parts. Your hands may suffer burns or frostbite if you touch the refrigerant pipes. To avoid injury, give the pipes time to return to normal temperature or, if you must touch them, be sure to wear proper gloves.
• Install drain piping to proper drainage. Improper drain piping may result in water leakage and property damage.
• Insulate piping to prevent condensation.
• Be careful when transporting the product.
• Do not turn off the power immediately after stopping operation. Always wait for at least 5 minutes before turning off the power. Otherwise, water leakage may occur.
• Do not use a charging cylinder. Using a charging cylinder may cause the refrigerant to deteriorate.
• Refrigerant R-410A in the system must be kept clean, dry, and tight.
(a) Clean and Dry -- Foreign materials (including
mineral oils such as SUNISO oil or moisture) should be prevented from getting into the system.
(b) Tight -- R-410A does not contain any chlorine,
does not destroy the ozone layer, and does not reduce the earth’s protection again harmful ultraviolet radiation. R-410A can contribute to the greenhouse effect if it is released. Therefore take proper measures to check for the tightness of the refrigerant piping installation. Read the chapter Refrigerant Piping and follow the procedures.
• Since R-410A is a blend, the required additional refrigerant must be charged in its liquid state. If the refrigerant is charged in a state of gas, its composition can change and the system will not work properly.
• The indoor unit is for R-410A. See the catalog for indoor models that can be connected. Normal operation is not possible when connected to other units.
• Remote controller (wireless kit) transmitting distance can be shorter than expected in rooms with electronic fluorescent lamps (inverter or rapid start types). Install the indoor unit far away from fluorescent lamps as much as possible.
• Indoor units are for indoor installation only. Outdoor units can be installed either outdoors or indoors. This unit is for indoor use.
• Do not install the air conditioner in the following locations: (a) Where a mineral oil mist or oil spray or vapor is
produced, for example, in a kitchen. Plastic parts may deteriorate and fall off or result in water leakage.
(b) Where corrosive gas, such as sulfurous acid gas, is
produced. Corroding copper pipes or soldered parts may result in refrigerant leakage.
(c) Near machinery emitting electromagnetic waves.
Electromagnetic waves may disturb the operation of the control system and cause the unit to malfunction.
(d) Where flammable gas may leak, where there is
carbon fiber, or ignitable dust suspension in the air, or where volatile flammables such as thinner or gasoline are handled. Operating the unit in such conditions can cause a fire.
• Take adequate measures to prevent the outside unit from being used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunctions, smoke, or fire. Instruct the customer to keep the area around the unit clean.
• Install the power supply and control wires for the indoor and outdoor units at least 3.5 feet away from televisions or radios to prevent image interference or noise. Depending on the radio waves, a distance of 3.5 feet may not be sufficient to eliminate the noise.
• Dismantling the unit, treatment of the refrigerant, oil and additional parts must be done in accordance with the relevant local, state, and national regulations.
• Do not use the following tools that are used with conventional refrigerants: gauge manifold, charge hose, gas leak detector, reverse flow check valve, refrigerant charge base, vacuum gauge, or refrigerant recovery equipment.
• If the conventional refrigerant and refrigerator oil are mixed in R-410A, the refrigerant may deteriorate.
• This air conditioner is an appliance that should not be accessible to the general public.
• As design pressure is 478 psi, the wall thickness of field-installed pipes should be selected in accordance with the relevant local, state, and national regulations.
Installation Manual EDUS041016
26 Room Air Conditioners J-Series
11.2 Indoor Unit Installation Instructions
2
Accessories
,
Choosing an Installation Site
• Before choosing the installation site, obtain user approval.
1.
Indoor unit
• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air inlet and air outlet have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range,
8)
the unit is at least 3.5 feet (1m) away from any television or radio set (unit may cause interference with the picture or sound),
9) no laundry equipment is located.
2.
Wireless remote controller
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote control signals are properly received by the indoor unit (within 23 feet (7m)).
Mounting plate
1
Remote controller holder
1
Operation manual
1
Mounting plate fixing screw
3/16” × 1” (M4 × 25mm)
6
Fixing screw for remote controller
holder 1/8” × 13/16” (M3 × 20mm)
2
Installation manual
1
Titanium apatite photocatalytic
air-purifying filter
2
Dry battery AAA. LR03
(alkaline)
2
Wireless remote controller
1
Indoor unit fixing screw
3/16” × 1/2” (M4 × 12mm)
2
Indoor unit
A
K
A
E
J
B
F
K
C
G
D
H
EDUS041016 Installation Manual
Room Air Conditioners J-Series 27
3
Preparation before Installation
1.
Removing and installing front panel
•Removal method
Hook fingers on the tabs on the left and right of the main body, and open until the panel stops. Slide the front panel sideways to disengage the rotating shaft. Then pull the front panel toward you to remove it.
••Installation method
Align the tabs of the front panel with the grooves, and push all the way in. Then close slowly. Push the center of the lower surface of the panel firmly to engage the tabs.
2.
Removing and installing front grille
R
emoval method
1) Remove front panel to remove the air filter.
2) Remove 2 screws from the front grille.
3) In front of the

mark of the front grille, there are 3 upper hooks. Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand.
When there is no work space because the unit is close to ceiling
CAUTION
• Be sure to wear protection gloves.
Place both hands under the center of the front grille, and while pushing up, pull it toward you.
• Installation method
1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 2 screws of the front grille.
3) Install the air filter and then mount the front panel.
3.
How to set the different addresses
When two indoor units are installed in one room, the two wireless remote controllers can be set for different addresses.
1) In the same way as when connecting to an HA system, remove the metal plate electrical wiring cover.
2) Cut the address jumper (JA) on the printed circuit board.
3) Cut the address jumper (J4) in the remote controller.
Push the rotating shaft of the front panel into the groove.
mar

k area
(3 locations)
Upper hook
Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand. (3 locations)
Push down.
Upper hook
1) Push up.
2) Pull toward you.
ADDRESS
EXIST
CUT12
JA
JA
ADDRESS
J4
EXIST
1
CUT 2
J4
Installation Manual EDUS041016
28 Room Air Conditioners J-Series
4
Indoor Unit Installation Drawings
3/16” × 5/8” (M4 × 16mm)
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally down in the direction of the arrow.
3) Pull down.
Wrap the insulation pipe with the finishing tape from bottom to top.
Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line.
Caulk pipe hole gap with putty.
Mounting plate
Clip
Mark (rear side)
Bottom frame
Front grille
How to attach the indoor unit
Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front grille.
How to remove the indoor unit
Push up the marked area (at the lower part of the front grille) to release the claws. If it is difficult to release, remove the front grille.
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1-3/16” (30mm) or more from ceiling
Front panel
1-15/16” (50mm) or more from walls (on both sides)
Air filters
Titanium apatite photocatalytic air-purifying filter (2)
Mounting plate
Air filter
Titanium apatite photocatalytic air-purifying filter
Filter frame
Ta b
Mounting plate fixing screw 3/16” × 1” (M4 × 25mm)
C
B
A
A
Before screwing the remote controller holder to the wall, make sure that control signals are properly received by indoor unit.
E Remote controller holder
Fixing screw for remote controller holder 1/8” × 13/16” (M3 × 20mm)
F
D Wireless remote controller
EDUS041016 Installation Manual
Room Air Conditioners J-Series 29
5
Indoor Unit Installation
1.
Installing the mounting plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the plate is completely level, and mark the boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
* The removed pipe port cover can be kept in the mounting plate pocket.
Removed pipe port cover
A
Mounting plate
Use tape measure as shown. Position the end of a tape measure at .
Liquid pipe end
Gas pipe end
Through­the-wall hole φ2-9/16 (φ65)
Recommended mounting plate retention spots (5 spots in all)
Place a leveler on raised tab.
9-33/64
(241.7)
1-5/8
(41.3)
13-1/64 (330.5)
13-1/32
(331)
6-19/64
(160)
2-1/8
(54)
30-5/16
(770)
9-33/64
(241.7)
1-5/8
(41.3)
2-9/64
(54.5)
6-19/64
(160)
1-31/32
(50)
4-31/32
(101)
4-47/64
(120.5)
7-63/64
(203)
9-23/32
(247)
Drain hose position
unit: inch (mm)
(Bolt size: 3/8 (M10)) (Bolt size: 3/8 (M10))