Daikin FXSQ63P7VEB user guide manual

INSTALLATION AND
OPERATION MANUAL
System air conditioners
FXSQ20P7VEB FXSQ25P7VEB FXSQ32P7VEB FXSQ40P7VEB FXSQ50P7VEB FXSQ63P7VEB FXSQ80P7VEB FXSQ100P7VEB FXSQ125P7VEB FXSQ140P7VEB
2
1
153
276
4
5
1 2
3
2 1
3 4 5
4
1 2
2 3
1
4 53
6a 6b 6c
200<45
1 3 442
680
1 56342
680
43
630 700
1 5342
A
B
4
2
680
7
6a
7a
180
425
160
(160~300)
1 3 52
460
6b 6c
7c
4
A
1
7a
7b
180
350
1 32
460
4
A
2
7b
8
9
26
7c
1
1
5 41 3
2
8 9
10
5
0~75
300 mm
4
1~1.5 m
3
1 2
625
A
56
10 11
11
100 mm
0~625 mm
1
1
.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
ATITIKTIES-DEKLARACIJA
ATBILSTĪBAS-DEKLARĀCIJA
VYHLÁSENIE-ZHODY
CE -
CE -
CE -
CE - UYUMLULUK-BİLDİRİSİ
ZJAVA O SKLADNOSTI
VASTAVUSDEKLARATSIOON
ДЕКЛАРАЦИЯ-ЗА-СЪОТВЕТСТВИЕ
CE - I
CE -
CE -
deklaruje na własną i wyłączną odpowiedzialność, że modele klimatyzatorów, których dotyczy niniejsza deklaracja:
declară pe proprie răspundere că aparatele de aer condiţionat la care se referă această declaraţie:
m
r
IZJAVA-O-USKLAĐENOSTI
DEKLARACJA-ZGODNOŚCI
DECLARAŢIE-DE-CONFORMITATE
CE - MEGFELELŐSÉGI-NYILATKOZAT
CE -
CE -
CE -
15
16
17
18
19
20
21
22
23
24
25
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
.
.
.
.
*
.
. 07
*
.
.
.
.
.
Direktive z vsemi spremembami.
Direktiivid koos muudatustega.
Директиви, с техните изменения.
Direktyvose su papildymais.
Direktīvās un to papildinājumos.
Smernice, v platnom znení.
Değiştirilmiş halleriyle Yönetmelikler.
Direktiver, med senere ændringer.
Direktiv, med företagna ändringar.
Direktiver, med foretatte endringer.
Direktiivejä, sellaisina kuin ne ovat muutettuina.
v platném znění.
Smjernice, kako je izmijenjeno.
irányelv(ek) és módosításaik rendelkezéseit.
z vso odgovornostjo izjavlja, da so modeli klimatskih naprav, na katere se izjava nanaša:
kinnitab oma täielikul vastutusel, et käesoleva deklaratsiooni alla kuuluvad kliimaseadmete mudelid:
декларира на своя отговорност, че моделите климатична инсталация, за които се отнася тази декларация:
visiška savo atsakomybe skelbia, kad oro kondicionavimo prietaisų modeliai, kuriems yra taikoma ši deklaracija:
ar pilnu atbildību apliecina, ka tālāk uzskaitīto modeĮu gaisa kondicionētāji, uz kuriem attiecas šī deklarācija:
vyhlasuje na vlastnú zodpovednosť, že tieto klimatizačné modely, na ktoré sa vzťahuje toto vyhlásenie:
tamamen kendi sorumluluğunda olmak üzere bu bildirinin ilgili olduğu klima modellerinin aşağıdaki gibi olduğunu beyan eder:
t
v
k
w
25
megfelelnek az alábbi szabvány(ok)nak vagy egyéb irányadó dokumentum(ok)nak, ha azokat előírás szerint használják:
spełniają wymogi następujących norm i innych dokumentów normalizacyjnych, pod warunkiem że używane są zgodnie z naszymi
instrukcjami:
sunt în conformitate cu următorul (următoarele) standard(e) sau alt(e) document(e) normativ(e), cu condiţia ca acestea să fie utilizate în
conformitate cu instrucţiunile noastre
skladni z naslednjimi standardi in drugimi normativi, pod pogojem, da se uporabljajo v skladu z našimi navodili:
on vastavuses järgmis(t)e standardi(te)ga või teiste normatiivsete dokumentidega, kui neid kasutatakse vastavalt meie juhenditele:
съответстват на следните стандарти или други нормативни документи, при условие, че се използват съгласно нашите
инструкции:
atitinka žemiau nurodytus standartus ir (arba) kitus norminius dokumentus su sąlyga, kad yra naudojami pagal mūsų nurodymus:
tad, ja lietoti atbilstoši ražotāja norādījumiem, atbilst sekojošiem standartiem un citiem normatīviem dokumentiem:
sú v zhode s nasledovnou(ými) normou(ami) alebo iným(i) normatívnym(i) dokumentom(ami), za predpokladu, že sa používajú v súlade
s našim návodom:
ürünün, talimatlarımıza göre kullanılması koşuluyla aşağıdaki standartlar ve norm belirten belgelerle uyumludur:
Directives, as amended.
Direktiven, gemäß Änderung.
Directives, telles que modifiées.
Richtlijnen, zoals geamendeerd.
Directivas, según lo enmendado.
Direttive, come da modifica.
√‰ËÁÈÒv, fiˆ˜ ¤¯Ô˘Ó ÙÚÔÔÔÈËı›.
*
**
o
x
b
.
.
i
.
.
.
*
<B>
pozitīvajam
и оценено
z późniejszymi poprawkami.
Directivelor, cu amendamentele respective.
<A>
<B>
съгласно
ir kaip teigiamai nuspręsta
<B>
un atbilstoši
<A>
<A>
Sertifikatą <C>
положително от
pagal
както е изложено в
Cертификата <C>
kaip nustatyta
kā norādīts
21 Забележка *
22 Pastaba *
23 Piezīmes *
Directivas, conforme alteração em.
Директив со всеми поправками.
, pozytywną opinią
şi apreciat pozitiv
igazolta a megfelelést,
<B>
alapján, a(z)
<A>
a(z)
Certificatul <C>
<A>
<A>
szerint.
în conformitate cu
Świadectwem <C>
<C> tanúsítvány
<B>
a(z)
de
zgodnie z dokumentacją
<B>
aşa cum este stabilit în
.
.
.
.
.
*
01
<A> DAIKIN.TCF.024D17/09-2009
<B> TÜV (NB1856)
<C> 0510260101
v
<B>
<C> Sertifikasına
a pozitívne zistené
sertifikātu <C>
<A>
tarafından olumlu olarak
<B>
osvedčením <C>
‘da belirtildiği gibi ve
vērtējumam saskaņā ar
değerlendirildiği gibi.
súlade s
ako bolo uvedené v
<A>
göre
Not
24 Poznámka *
25
v
<B>
ja heaks
<A>
sertifikaadile <C>
in odobreno s strani
<A>
järgi vastavalt
certifikatom <C>
<B>
kiidetud
kot je določeno v
nagu on näidatud dokumendis
skladu s
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Daikin Europe N.V. je pooblaščen za sestavo datoteke s tehnično mapo.
Daikin Europe N.V. on volitatud koostama tehnilist dokumentatsiooni.
Daikin Europe N.V. е оторизирана да състави Акта за техническа конструкция.
Daikin Europe N.V. yra įgaliota sudaryti šį techninės konstrukcijos failą.
Daikin Europe N.V. ir autorizēts sastādīt tehnisko dokumentāciju.
Spoločnosť Daikin Europe N.V. je oprávnená vytvoriť súbor technickej konštrukcie.
**
21
**
22
**
23
**
24
Daikin Europe N.V. Teknik Yapı Dosyasını derlemeye yetkilidir.
**
25
**
19
**
20
PROHLÁŠENÍ-O-SHODĚ
CE - ERKLÆRING OM-SAMSVAR
CE - ILMOITUS-YHDENMUKAISUUDESTA
CE -
заявляет, исключительно под свою ответственность, что модели кондиционеров воздуха, к которым относится настоящее заявление:
erklærer under eneansvar, at klimaanlægmodellerne, som denne deklaration vedrører:
u
q
CE - DECLARAÇÃO-DE-CONFORMIDADE СЕ - ЗАЯВЛЕНИЕ-О-СООТВЕТСТВИИ
CE - OPFYLDELSESERKLÆRING
CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE
CE - ¢H§ø™H ™YMMOPºø™H™
CE - DECLARACION-DE-CONFORMIDAD
CE - DICHIARAZIONE-DI-CONFORMITA
prohlašuje ve své plné odpovědnosti, že modely klimatizace, k nimž se toto prohlášení vztahuje:
izjavljuje pod isključivo vlastitom odgovornošću da su modeli klima uređaja na koje se ova izjava odnosi:
deklarerar i egenskap av huvudansvarig, att luftkonditioneringsmodellerna som berörs av denna deklaration innebär att:
erklærer et fullstendig ansvar for at de luftkondisjoneringsmodeller som berøres av denne deklarasjon innebærer at:
s
n
teljes felelőssége tudatában kijelenti, hogy a klímaberendezés modellek, melyekre e nyilatkozat vonatkozik:
ilmoittaa yksinomaan omalla vastuullaan, että tämän ilmoituksen tarkoittamat ilmastointilaitteiden mallit:
j
c
y
h
declaración:
referencia la
estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s) documento(s) normativo(s), desde que estes sejam utilizados de
acordo com as nossas instruções:
соответствуют следующим стандартам или другим нормативным документам, при условии их использования согласно нашим
инструкциям:
overholder følgende standard(er) eller andet/andre retningsgivende dokument(er), forudsat at disse anvendes i henhold til vore
instrukser:
respektive utrustning är utförd i överensstämmelse med och följer följande standard(er) eller andra normgivande dokument, under
förutsättning att användning sker i överensstämmelse med våra instruktioner:
respektive utstyr er i overensstemmelse med følgende standard(er) eller andre normgivende dokument(er), under forutssetning av at
disse brukes i henhold til våre instrukser:
vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien vaatimuksia edellyttäen, että niitä käytetään ohjeidemme
mukaisesti:
za předpokladu, že jsou využívány v souladu s našimi pokyny, odpovídají následujícím normám nebo normativním dokumentům:
u skladu sa slijedećim standardom(ima) ili drugim normativnim dokumentom(ima), uz uvjet da se oni koriste u skladu s našim uputama:
Low Voltage 2006/95/EC
Machinery 98/37/EC ( 29/12/2009)
Machinery 2006/42/EC (29/12/2009 )
Electromagnetic Compatibility 2004/108/EC
ob upoštevanju določb:
vastavalt nõuetele:
следвайки клаузите на:
laikantis nuostatų, pateikiamų:
ievērojot prasības, kas noteiktas:
održiavajúc ustanovenia:
bunun koşullarına uygun olarak:
under iagttagelse af bestemmelserne i:
enligt villkoren i:
gitt i henhold til bestemmelsene i:
noudattaen määräyksiä:
za dodržení ustanovení předpisu:
prema odredbama:
követi a(z):
zgodnie z postanowieniami Dyrektyw:
în urma prevederilor:
Notă *
16 Megjegyzés *
17 Uwaga *
18
on
<B>
ja jotka
enligt
<B>
och godkänts av
<A>
enligt
11 Information *
e giudicato positivamente
<A>
delineato nel
mukaisesti.
<A>
Sertifikat <C>
og gjennom positiv
<A>
ifølge
<B>
Sertifikaatin <C>
hyväksynyt
Certifikatet <C>
som det fremkommer i
bedømmelse av
jotka on esitetty asiakirjassa
12 Merk *
13 Huom *
Certificado <C>
¶ИЫЩФФИЛЩИОfi <C>
e com o parecer
Î·È ÎÚ›ÓÂÙ·È ıÂÙÈο
<A>
<A>
Certificato <C>
de acordo com o
Û‡Ìʈӷ Ì ÙÔ
<B>
<B>
secondo il
<B>
positivo de
·fi ÙÔ
tal como estabelecido em
da
* fiˆ˜ ηıÔÚ›˙ÂÙ·È ÛÙÔ
™ËÌ›ˆÛË
06 Nota *
08 Nota
<B>
positiv
<B>
<C>
<C>
et évalué positivement par
Certificat <C>
<A>
Certificate
and judged positively by
Zertifikat
aufgeführt und von
<A>
<A>
conformément au
beurteilt gemäß
according to the
as set out in
wie in der
tel que défini dans
<B>
Daikin Europe N.V. on valtuutettu laatimaan Teknisen asiakirjan.
Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce.
Daikin Europe N.V. je ovlašten za izradu Datoteke o tehničkoj konstrukciji.
**
**
**
14
19 Opomba *
20 Märkus
v
<B>
a pozitivně zjištěno
i pozitivno ocijenjeno od
<A>
Certifikatu <C>
<A>
prema
osvědčením <C>
<B>
strane
jak bylo uvedeno v
kako je izloženo u
souladu s
14 Poznámka *
15 Napomena *
i
<B>
согласно
<B>
и в соответствии с
og positivt vurderet af
<A>
<A>
Certifikat <C>
положительным решением
henhold til
как указано в
Свидетельству <C>
som anført i
09 Примечание *
10 Bemærk *
y es valorado
de acuerdo con el
<A>
Certificaat <C>
en positief beoordeeld door
<B>
<A>
overeenkomstig
zoals vermeld in
<B>
como se establece en
Certificado <C>
positivamente por
15
13
∏ Daikin Europe N.V. Â›Ó·È ÂÍÔ˘ÛÈÔ‰ÔÙË̤ÓË Ó· Û˘ÓÙ¿ÍÂÈ ÙÔÓ ∆¯ÓÈÎfi Ê¿ÎÂÏÔ Î·Ù·Û΢‹˜.
A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico.
Компания Daikin Europe N.V. уполномочена составить Комплект технической документации.
**
**
**
08
09
07
A Daikin Europe N.V. jogosult a műszaki konstrukciós dokumentáció összeállítására.
Daikin Europe N.V. ma upoważnienie do zbierania i opracowywania dokumentacji konstrukcyjnej.
Daikin Europe N.V. este autorizat să compileze Dosarul tehnic de construcţie.
**
**
**
16
18
17
Jiro Tomita
Director Quality Assurance
Ostend, 1st of December 2009
Daikin Europe N.V. er autoriseret til at udarbejde de tekniske konstruktionsdata.
Daikin Europe N.V. är bemyndigade att sammanställa den tekniska konstruktionsfilen.
Daikin Europe N.V. har tillatelse til å kompilere den Tekniske konstruksjonsfilen.
**
**
**
10
11
12
declares under its sole responsibility that the air conditioning models to which this declaration relates:
erklärt auf seine alleinige Verantwortung daß die Modelle der Klimageräte für die diese Erklärung bestimmt ist:
déclare sous sa seule responsabilité que les appareils d'air conditionné visés par la présente déclaration:
verklaart hierbij op eigen exclusieve verantwoordelijkheid dat de airconditioning units waarop deze verklaring betrekking heeft:
declara baja su única responsabilidad que los modelos de aire acondicionado a los cuales hace
dichiara sotto sua responsabilità che i condizionatori modello a cui è riferita questa dichiarazione:
‰ЛПТУВИ МВ ·ФОПВИЫЩИО‹ ЩЛ˜ В˘ı‡УЛ fiЩИ Щ· МФУЩ¤П· ЩˆУ ОПИМ·ЩИЫЩИОТУ Ы˘ЫОВ˘ТУ ЫЩ· ФФ›· ·У·К¤ЪВЩ·И Л ·ЪФ‡Ы· ‰‹ПˆЫЛ:
a
d
f
l
e
i
CE - DECLARATION-OF-CONFORMITY
CE - KONFORMITÄTSERKLÄRUNG
CE - DECLARATION-DE-CONFORMITE
CE - CONFORMITEITSVERKLARING
Daikin Europe N.V.
g
declara sob sua exclusiva responsabilidade que os modelos de ar condicionado a que esta declaração se refere:
p
FXSQ20P7VEB*, FXSQ25P7VEB*, FXSQ32P7VEB*, FXSQ40P7VEB*, FXSQ50P7VEB*, FXSQ63P7VEB*, FXSQ80P7VEB*, FXSQ100P7VEB*, FXSQ125P7VEB*, FXSQ140P7VEB*,
* = , , 1, 2, 3, ..., 9
are in conformity with the following standard(s) or other normative document(s), provided that these are used in accordance with our
instructions:
der/den folgenden Norm(en) oder einem anderen Normdokument oder -dokumenten entspricht/entsprechen, unter der Voraussetzung,
daß sie gemäß unseren Anweisungen eingesetzt werden:
sont conformes à la/aux norme(s) ou autre(s) document(s) nor matif(s), pour autant qu'ils soient utilisés conformément à nos instructions:
conform de volgende norm(en) of één of meer andere bindende documenten zijn, op voorwaarde dat ze worden gebruikt overeenkomstig
onze instructies:
están en conformidad con la(s) siguiente(s) norma(s) u otro(s) documento(s) nor mativo(s), siempre que sean utilizados de acuerdo con
Daikin Europe N.V. is authorised to compile the Technical Construction File.
Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen.
Daikin Europe N.V. est autorisé à compiler le Dossier de Construction Technique.
Daikin Europe N.V. is bevoegd om het Technisch Constructiedossier samen te stellen.
Daikin Europe N.V. está autorizado a compilar el Archivo de Construcción Técnica.
following the provisions of:
gemäß den Vorschriften der:
conformément aux stipulations des:
overeenkomstig de bepalingen van:
siguiendo las disposiciones de:
secondo le prescrizioni per:
Ì ًÚËÛË Ùˆv ‰È·Ù¿Íˆv Ùˆv:
de acordo com o previsto em:
nuestras instrucciones:
sono conformi al(i) seguente(i) standard(s) o altro(i) documento(i) a carattere normativo, a patto che vengano usati in conformità alle
nostre istruzioni:
В›У·И Ы‡МКˆУ· МВ ЩФ(·) ·ОfiПФ˘ıФ(·) ЪfiЩ˘Ф(·) ‹ ¿ППФ ¤ББЪ·КФ(·) О·УФУИЫМТУ, ˘fi ЩЛУ ЪФ¸fiıВЫЛ fiЩИ ¯ЪЛЫИМФФИФ‡УЩ·И
Û‡Ìʈӷ Ì ÙȘ Ô‰ËÁ›Â˜ Ì·˜:
EN60335-2-40,
в соответствии с положениями:
01 Note *
02 Hinweis *
03 Remarque *
04 Bemerk *
05 Nota
** 01
** 02
** 03
** 04
** 05
Daikin Europe N.V. è autorizzata a redigere il File Tecnico di Costruzione.
** 06
3PW46981-6C
FXSQ20P7VEB FXSQ50P7VEB FXSQ100P7VEB FXSQ25P7VEB FXSQ63P7VEB FXSQ125P7VEB FXSQ32P7VEB FXSQ80P7VEB FXSQ140P7VEB FXSQ40P7VEB
VRV System air conditioners
Installation and
operation manual
CONTENTS Page
Before installation.............................................................................. 1
Important information regarding the refrigerant used........................ 2
Selecting installation site................................................................... 2
Preparations before installation......................................................... 3
Indoor unit installation .......................................................................4
Refrigerant piping work .....................................................................4
Drain piping work .............................................................................. 5
Electric wiring work ........................................................................... 6
Wiring example and how to set the remote controller ....................... 7
Wiring example ................................................................................. 8
Field setting....................................................................................... 8
Installation of the decoration panel ................................................. 10
Test operation.................................................................................. 10
Maintenance.................................................................................... 10
Disposal requirements .................................................................... 11
Wiring diagram ................................................................................ 12
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE AND INFORMATION.
The English text is the original instruction. Other languages are translations of the original instructions.
Installation must be done by a licensed technician. The choice of materials and installation must comply with the applicable national and international regulations.

BEFORE INSTALLATION

Leave the unit inside its packaging until you reach the installation site. Where unpacking is unavoidable, use a sling of soft material or protective plates together with a rope when lifting, this to avoid damage or scratches to the unit.
Refer to the installation manual of the outdoor unit for items not described in this manual.
Caution concerning refrigerant series R410A: The connectable outdoor units must be designed exclusively for
R410A.
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts.

Precautions

Do not install or operate the unit in rooms mentioned below.
- Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)
- Where corrosive gas like sulphurous gas exists. (Copper
tubing and brazed spots may corrode.)
- Where volatile flammable gas like thinner or gasoline is used.
- Where machines generating electromagnetic waves exist.
(Control system may malfunction.)
- Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories). Also in vehicles or vessels.
Do not install accessories on the casing directly. Drilling holes in the casing may damage electrical wires and consequently cause fire.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Accessories

Check if the following accessories are included with your unit.
12
Installation and operation manual
1
Metal clamp
1 piece
Large sealing pad
1 piece
Other: installation and operation manual
Drain hose
1 piece
Insulation for fitting
for gas pipe
1 piece
Washer for
hanging bracket
8 pieces
for liquid pipe
1 piece
Screws for fixing panels are attached to the air inlet panel.
VRV System air conditioners
Medium
sealing pad
2 pieces
Screws for duct
flanges
1 set
16 pieces
FXSQ20~140P7VEB
4PW56483-1

Optional accessories

There are two types of remote controllers: wired and wireless. Select a remote controller according to customer request and install in an appropriate place. Refer to catalogues and technical literature for selecting a suitable remote controller.
When installing bottom suction: air inlet panel and canvas connection for the air inlet panel.
For the following items, take special care during construction and check after installation is finished
Tick
when
checked
Is the indoor unit fixed firmly?
The unit may drop, vibrate or make noise.
Is the gas leak test finished?
It may result in insufficient cooling or heating.
Is the unit fully insulated and checked for air leaks?
Condensate water may drip.
Does drainage flow smoothly?
Condensate water may drip.
Does the power supply voltage correspond to that shown on the name plate?
The unit may malfunction or components may burn out.
Are wiring and piping correct?
The unit may malfunction or components may burn out.
Is the unit safely grounded?
Dangerous at electric leakage.
Is the wiring size according to specifications?
The unit may malfunction or components may burn out.
Is nothing blocking the air outlet or inlet of either the indoor or outdoor units?
It may result in insufficient cooling or heating.
Are refrigerant piping length and additional refrigerant charge noted down?
The refrigerant charge in the system might not be clear.
Are the air filters fixed properly (when installing with rear duct)?
Maintenance of the air filters can be impossible.
Is the external static pressure set?
It may result in insufficient cooling or heating.

SELECTING INSTALLATION SITE

(See figure 1 and figure 2)
1 Select an installation site where the following conditions are
fulfilled and that meets your customer's approval.
- Where optimum air distribution can be ensured.
- Where nothing blocks air passage.
- Where condensate water can be properly drained.
- Where the false ceiling is not noticeably on an incline.
- Where sufficient clearance for maintenance and service can be ensured.
- Where there is no risk of flammable gas leaking.
- The equipment is not intended for use in a potentially explosive atmosphere.
- Where piping between indoor and outdoor units is possible within the allowable limit. (Refer to the installation manual of the outdoor unit.)
-Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away from televisions and radios. This is to prevent image interference and noise in those electrical appliances. (Noise may be generated depending on the conditions under which the electric wave is generated, even if 1 meter is kept.)
- When installing the wireless remote controller kit, the distance between wireless remote controller and indoor unit might be shorter if there are fluorescent lights who are electrically started in the room. The indoor unit must be installed as far as possible away from fluorescent lights.
- Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
2 Ensure that a protective guard is installed on air suction and air
outlet side to prevent that the fan blades or heat exchanger be touched.
The protection must comply with relevant European and national regulations.
3 Use suspension bolts for installation. Check whether the ceiling
is strong enough to support the weight of the indoor unit. If there is a risk, reinforce the ceiling before installing the unit.

Notes to the installer

Read this manual carefully to ensure correct installation. Be sure to instruct the customer how to properly operate the system and show him/her the enclosed operation manual.
Explain to the customer what system is installed on the site. Be sure to fill out the appropriate installation specifications in the chapter "What to do before operation" of the outdoor unit operation manual.
IMPORTANT INFORMATION REGARDING THE
REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Refrigerant type: R410A
(1)
GWP
value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
1 Service space 2 Drain pipe 3 Power supply wiring port 4 Tr ansmission wiring port 5 Maintenance drain outlet 6 Gas pipe 7 Liquid pipe
FXSQ20~140P7VEB VRV System air conditioners 4PW56483-1
Installation and operation manual
2

PREPARATIONS BEFORE INSTALLATION

1 Relation of ceiling opening to unit and suspension bolt position.
(See figure 5)
Model A (mm) B (mm)
20~32 550 586 40+50 700 738 63+80 1000 1038 100~140 1400 1438
1 Indoor unit 2 Pipe 3 Suspension bolt pitch (x4) 4 Suspension bolt pitch distance
For installation, choose one of the possibilities as listed further.
Mounting the air inlet panel with a canvas connection (See
figure 7a)
Mounting the air inlet panel directly (See figure 7b)
1 Ceiling surface 2 Ceiling opening 3 Air inlet panel (Optional accessory) 4 Indoor unit (Back side) 5 Canvas connection for air inlet panel (Optional accessory)
Model A (mm)
20~32 610 40+50 760 63+80 1060 100~140 1460
Standard rear suction (See figure 6a)
1 Ceiling surface 2 Ceiling opening 3 Service access panel (optional accessory) 4 Air filter 5 Air inlet duct 6 Duct service opening 7 Interchangeable plate
Installation with rear duct and duct service opening (See
figure 6b)
Installation with rear duct, no duct service opening (See
figure 6c)
NOTE
Before installation of the unit (in case of installation with duct, but no duct service opening): modify the position of the air filters.
1 Remove the air filter(s) at the
outside of the unit
2 Remove the interchangeable
plate
3 Install the air filter(s) from the
inside of the unit
4 Reinstall the interchangeable
plate
3
2
4
Bottom suction (See figure 7c)
NOTE
NOTE
2 The fan speed for this indoor unit is preset to provide standard
3 Install the suspension bolts.
Installation example
(See figure 3)
1
The unit can be used with bottom suction by replacing the interchangeable plate by the air filter holding plate.
1 Air filter holding plate with air filter(s) 2 Interchangeable plate
For other installation than standard installation, contact your Daikin dealer for details.
external static pressure.
(Use M10 size bolt for the suspension bolt.) Use anchors for existing ceilings, and a sunken insert, sunken anchors or other field supplied parts for new ceilings to reinforce the ceiling in order to bear the weight of the unit.
1 Anchor 2 Ceiling slab 3 Long nut or turn-buckle 4 Suspension bolt 5 Indoor unit
NOTE
When installing an air inlet duct, select fixing screws that shall stick out maximum 5 mm at the inside of the flange to protect the air filter from damage during maintenance of the filter.
1 Air inlet duct
2 Inside of the flange
3 Fixing screw
Installation and operation manual
3
12
3
5 mm
NOTE
All the above parts are field supplied.
VRV System air conditioners
FXSQ20~140P7VEB
4PW56483-1

INDOOR UNIT INSTALLATION

C
356
6
C
356
6
When installing optional accessories (except for the air inlet panel), read also the installation manual of the optional accessories. Depending on the field conditions, it may be easier to install optional accessories before the indoor unit is installed.
1 Install the indoor unit temporarily.
- Attach the hanger bracket to the suspension bolt. Be sure to
fix it securely by using a nut and washer from the upper and lower sides of the hanger bracket. (See figure 4)
1 Nut (field supply) 2 Washer for hanger bracket (supplied with the unit) 3 Tighten (double nut)
2 Check if the unit is horizontally levelled.
- Do not install the unit tilted. The indoor unit is equipped with a
built-in drain pump and float switch. (If the unit is tilted against condensate flow, the float switch may malfunction and cause water to drip.)
- Check if the unit is levelled at all four corners with a water
level or a water-filled vinyl tube as shown in figure 9.
1 Water level 2 Vinyl tube
3 Tighten the upper nut.

REFRIGERANT PIPING WORK

Refer to Ta b le 1 for the dimensions of flare nut spaces and the appropriate tightening torque. (Overtightening may damage the flare and cause leaks.) Ta ble 1
Pipe
gauge
(mm)
Ø6.4 15~17 8.7~9.1
Ø9.5 33~39 12.8~13.2 Ø12.7 50~60 16.2~16.6 Ø15.9 63~75 19.3~19.7
Tightening torque
(N•m)
Flare dimension
A (mm)
Flare shape
±2
90°
45°
±2
A
R=0.4~0.8
When connecting the flare nut, coat the flare inner surface with ether oil or ester oil and initially tighten 3 or 4 turns by hand before tightening firmly.
If the refrigerant gas leaks during the work, ventilate the area. A toxic gas is emitted by the refrigerant gas being exposed to a fire.
Make sure there is no refrigerant gas leak. A toxic gas may be released by the refrigerant gas leaking indoor and being exposed to flames from an area heater, cooking stove, etc.
Finally, insulate as shown in the figures below.
Piping insulation procedure
Gas piping Liquid piping
For refrigerant piping of outdoor unit, refer to the installation manual supplied with the outdoor unit.
Before rigging tubes, check which type of refrigerant is used.
All field piping must be provided by a licensed refrigeration technician and must comply with the relevant local and national codes.
Use a pipe cutter and flare suitable for the used refrigerant.
To prevent dust, moisture or other foreign matter from infiltrating
the tube, either pinch the end, or cover it with tape.
Use copper alloy seamless pipes (ISO 1337).
The outdoor unit is charged with refrigerant.
To prevent water leakage, execute heat insulation work
completely on both sides of the gas and liquid piping. When using a heat pump, the temperature of the gas piping can reach up to approximately 120°C, use insulation which is sufficiently heat resistant.
Be sure to use both a spanner and torque wrench together when connecting or disconnecting pipes to/from the unit.
1 Torque wrench 2 Spanner 3 Piping union 4 Flare nut
12
3
4
Do not mix anything other than the specified refrigerant, such as air, etc..., inside the refrigerant circuit.
Use annealed material only for flare connections.
1 Piping insulation material (field supply) 2 Flare nut connection 3 Insulation for fitting (delivered with the unit) 4 Piping insulation material (main unit) 5 Main unit 6 Clamp (field supply) 7 Medium 1 sealing pad for gas piping (delivered with the unit)
Medium 2 sealing pad for liquid piping (delivered with the unit)
A Turn seams up B Attach to base C Tighten the part other than the piping insulation material D Wrap over from the base of the unit to the top of the flare nut
connection
For local insulation, be sure to insulate local piping all the way into the pipe connections inside the unit.
Exposed piping may cause condensation or may cause burns when touched.
FXSQ20~140P7VEB VRV System air conditioners 4PW56483-1
Installation and operation manual
4

Cautions for brazing

A'
Be sure to carry out a nitrogen blow when brazing. Brazing without carrying out nitrogen replacement or releasing nitrogen into the piping will create large quantities of oxidized film on the inside of the pipes, adversely affecting valves and compressors in the refrigerating system and preventing normal operation.
When brazing while inserting nitrogen into the piping, nitrogen must be set to 0.02 MPa with a pressure-reducing valve (=just enough so that it can be felt on the skin).
12 345
6
1 Refrigerant piping 2 Part to be brazed 3 Taping 4 Hands valve 5 Pressure-reducing valve 6 Nitrogen
6

DRAIN PIPING WORK

Rig the drain piping as shown in the figure and take measures against condensation. Improperly rigged piping could lead to leaks and eventually wet furniture and belongings.
1-1.5 m
1 Hanging bar
Install the drain pipes.
-Keep piping as short as possible and slope it downwards at a
gradient of at least 1/100 so that air may not remain trapped inside the pipe.
-Keep pipe size equal to or greater than that of the connecting
pipe (vinyl pipe of 25 mm nominal diameter and 32 mm outer diameter).
- Push the supplied drain hose as far as possible over the
drain socket.
- Tighten the metal clamp until the screw head is less than
4 mm from the metal clamp part as indicated in the illustration.
1 23 5
A
A
1
4
- Insulate the complete drain piping inside the building (field supply).
- If the drain hose cannot be sufficiently set on a slope, fit the hose with drain raising piping (field supply).
How to perform drain piping (See figure 10)
1 Ceiling slab 2 Hanger bracket 3 Adjustable range 4 Drain raising pipe 5 Drain hose (supplied with the unit) 6 Clamp metal (supplied with the unit)
1 Connect the drain hose to the drain raising pipes, and insulate
them.
2 Connect the drain hose to the drain outlet on the indoor unit, and
tighten it with the clamp.
Installation A (mm)
Rear suction installation 231 When canvas duct is installed 350-530 When air inlet panel is directly installed 231
Precautions
- Install the drain raising pipes at a height of less than 625 mm.
- Install the drain raising pipes at a right angle to the indoor unit and no more than 300 mm from the unit.
-To prevent air bubbles, install the drain hose level or slightly tilted up (75 mm).
NOTE
The incline of attached drain hose should be 75 mm or less so that the drain socket does not have to withstand additional force.
To ensure a downward slope of 1:100, install hanging bars every 1 to 1.5 m.
When unifying multiple drain pipes, install the pipes as shown in figure 11. Select converging drain pipes whose gauge is suitable for the operating capacity of the unit.
1 T-joint converging drain pipes

Testing of drain piping

After piping work is finished, check if drainage flows smoothly.
Add approximately 1 l of water gradually through the air discharge outlet. Check for water leaks. Method of adding water. See figure 8.
1 Water inlet 2 Portable pump 3 Water inlet cover 4 Bucket (adding water through water inlet) 5 Drain outlet for maintenance (with rubber drain plug) 6 Refrigerant pipes
A'
A'
4 mm
A-A'
1 Drain socket (attached to the unit) 2 Drain hose (supplied with the unit) 3 Metal clamp (supplied with the unit) 4 Drain piping (field supply) 5 Large sealing pad (supplied with the unit)
-Wrap the supplied large sealing pad over the metal clamp and drain hose to insulate and fix it with clamps.
Installation and operation manual
5
5 3
1 2
FXSQ20~140P7VEB
VRV System air conditioners
4PW56483-1
Caution for drain socket
Do not remove the drain pipe plug. Water might leak out. The drain outlet is only used to discharge water if the drain
pump is not used or before maintenance. Gently put in and out the drain plug. Excessive force may deform the drain socket of the drain pan.
Pulling out the plug
1
1 Drain plug
Do not wiggle the plug up and down
Pushing in the plug
1
2
1 Drain plug 2 Crosshead screwdriver
Set the plug and push it by using a crosshead screw­driver
First perform electric wiring work as instructed in "Electric wiring
work" on page 6 and how to set the remote controller as explained in "Wiring example and how to set the remote controller" on page 7.
When electric wiring work is finished
Check drainage flow during COOL running, explained in "Test operation"
on page 10.
When electric wiring work is not finished
Remove the switch box cover and connect the single-phase power supply and the remote controller to the terminals. (Refer to "Electric
wiring work" on page 6 for switch box attachment/detachment.)
(Refer to figure 12 and figure 14)
1 Switch box cover 2 Tr ansmission wiring port 3 Power supply wiring port 4 Wiring diagram 5 Switch box 6 Plastic clamp 7 Remote controller wiring 8 Te r minal board for unit transmission wiring
9 Power supply wiring 10 Indoor PC board 1 11 Power supply terminal board 12 Tr ansmission wiring between units 13 Indoor PC board 2 14 Indoor PC board 3 (only for 63~140 units)

ELECTRIC WIRING WORK

General instructions

All field supplied parts and materials and electric works must conform to local codes.
Use copper wire only.
Follow the "Wiring diagram" attached to the unit body to wire the
outdoor unit, indoor units and the remote controller. For details on hooking up the remote controller, refer to the "Installation manual of the remote controller".
All wiring must be performed by an authorized electrician.
Attach the earth leakage circuit breaker and fuse to the power
supply line.
A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated in the fixed wiring in accordance with relevant local and national legislation. Note that the operation will restart automatically if the main power supply is turned off and then turned back on again.
This system consists of multiple indoor units. Mark each indoor unit as unit A, unit B..., and be sure the terminal block wiring to the outdoor unit and BS unit are properly matched. If wiring and piping between the outdoor unit and an indoor unit are mismatched, the system may cause a malfunction.
Be sure to ground the air conditioner.
Do not connect the ground wire to:
- gas pipes: might cause explosions or fire if gas leaks.
- telephone ground wires or lightning rods: might cause
abnormally high electric potential in the ground during lightning storms.
- plumbing pipes: no grounding effect if hard vinyl piping is
used.
Make sure electrical wires are stripped equally.

Electrical characteristics

Power supply
Model Hz Vol ts Voltage range
20 25 0.5 32 0.5 40 1.2 50 1.2 63 1.1 80 1.3 100 1.4 125 1.9 140 3.1
50/60 220-240/220 ±10%
MCA: Min. circuit Amps (A) MFA: Max. Fuse Amps (A)
NOTE
For details, refer to "Electrical data" in the technical data book.
MCA MFA
0.5
16 A
Next, press the inspection/test operation button on the remote controller. The unit will engage the test operation mode. Press the operation mode selector button until selecting fan operation
. Then, press the on/off button . The indoor unit fan and drain pump will start up. Check that the water has drained from the unit. Press to go back to the first mode.
FXSQ20~140P7VEB VRV System air conditioners 4PW56483-1
Installation and operation manual
6
Specifications for field supplied fuses and wire
Power supply wiring
Model Field fuses Wire Size
20~140 16 A H05VV-U3G Local codes
- When connecting wires of the same gauge, connect them according to the figure.
Model Wire Size
20~140 Sheathed wire (2)
NOTE
For details, refer to "Wiring example" on page 8.
0.75-1.25 mm
2
Allowable length of transmission wiring between indoor and outdoor units, and between the indoor unit and the remote controller is as follows:
1. Outdoor unit - indoor unit: max. 1000 m (total wiring length: 2000 m)
2. Indoor unit - remote controller: max 500 m
WIRING EXAMPLE AND HOW TO SET THE
REMOTE CONTROLLER

How to connect wiring

Remove the switch box cover as shown in figure 12, and make the connections.
1 Switch box cover 2 Tr ansmission wiring port 3 Power supply wiring port 4 Wiring diagram 5 Switch box
PRECAUTIONS
1 Observe the notes mentioned below when wiring to the power
supply terminal board.
- Use a round crimp-style terminal for insulation sleeve for
connection to the terminal block for wiring the units. When none are available, follow the instructions below.
1 Round crimp-style terminal 2 Attach insulation sleeve
1 2 3
- Do not connect wires of different gauge to the same power
supply terminal. (Looseness in the connection may cause overheating.)
3 Wiring
Use the specified electric wire. Connect the wire securely to the terminal. Lock the wire down without applying excessive force to the terminal. Use torques according to the table below.
Tightening torque (N•m)
Te r minal block for unit transmission and remote controller
Te r minal block for power supply 1.2
0.9
- When attaching the control box lid, make sure not to pinch any wires.
- After all wiring connections are done, fill in any gaps in the casing wiring holes with putty or insulation material (field supply) thus to prevent small animals or dirt from entering the unit from outside and causing short circuits in the control box.
2 Keep total current of crossover wiring between indoor units less
than 12 A. Branch the line outside the terminal board of the unit in accordance with electrical equipment standards, when using
two power wiring of a gauge greater than 2 mm
2
(Ø1.6).
The branch must be sheathed in order to provide an equal or greater degree of insulation as power supply wiring itself.
3 Do not connect wires of different gauge to the same grounding
terminal. Looseness in the connection may deteriorate the protection.
4 Remote controller cords and wires connecting the units should
be located at least 50 mm away from power supply wiring. Not following this guideline may result in malfunction due to electrical noise.
5 For the remote controller wiring, refer to the "Installation manual
of the remote controller" supplied with the remote controller.
6 Never connect the power supply wiring to the terminal board for
transmission wiring. This mistake could damage the entire system.
7 Use only specified wires and tightly connect wires to the
terminals. Be careful that wires do not place external stress on the terminals. Keep wiring in neat order so that they do not obstruct other equipment such as popping open the switch box cover. Make sure the cover closes tight. Incomplete connections could result in overheating, and in the worse case, electric shock or fire.
Installation and operation manual
7
FXSQ20~140P7VEB
VRV System air conditioners
4PW56483-1

WIRING EXAMPLE

FIELD SETTING

Fit the power supply wiring of each unit with a switch and fuse as shown in figure 16.
1 Power supply 2 Main switch 3 Power supply wiring 4 Tr ansmission wiring 5 Switch 6 Fuse 7 BS unit REYQ only 8 Indoor unit 9 Remote controller
Complete system example (3 systems)
When using 1 remote controller for 1 indoor unit (Normal operation)
(See figure 15)
For group control or use with 2 remote controllers (See figure 17) When including BS unit (See figure 13)
1 Outdoor unit 2 Indoor unit 3 Remote controller (optional accessories) 4 Most downstream indoor unit 5 For use with 2 remote controllers 6 BS unit
NOTE
PRECAUTIONS
A single switch can be used to supply power to units on the same system. However, branch switches and branch circuit breakers must be selected carefully.
For a group control remote controller, choose the remote controller that suits the indoor unit which has the most functions.
Do not ground the equipment on gas pipes, water pipes, lightning rods or crossground with telephones. Improper grounding could result in electric shock.
It is not necessary to designate an indoor unit address when using group control. The address is automatically set when the power is activated.
Field setting must be made on the remote controller in function of the installation condition.
Setting can be made by changing the "Mode number", "First code No." and "Second code No.".
For setting and operation, refer to the "Field settings" in the installation manual of the remote controller.
Summary of field settings
Mode
First
No.
code
(Note 1)
No.
Description of setting
Filter contamination
- Heavy/Light = Setting to define time between 2 filter cleaning display indications. (When
0
contamination is high, setting can be changed to half the time inbetween 2 filter cleaning display indications.)
10
(20)
12
(22)
15
(25)
Note 1 : Setting is carried out in the group mode, however, if the mode number inside parentheses is selected,
Note 2 : Factory settings of the Second code No. are marked in grey backgrounds. Note 3 : Only use in combination with optional remote sensor or when setting 10-2-03 is used. Note 4 : If group control is selected and remote control sensor is to be used, then set 10-6-02 & 10-2-03. Note 5 : If setting 10-6-02 + 10-2-01 or 10-2-02 or 10-2-03 are set at the same time, then setting 10-2-01,
Note 6 : If setting 10-6-01 + 10-2-01 or 10-2-02 or 10-2-03 are set at the same time, then setting for group
Note 7 : More settings for Differential automatic change over temperatures are:
Thermostat sensor selection
2
Setting for display of time between 2 filter cleaning display
3
indications
Thermostat sensor in group
6
control
Output signal X1-X2 of the
0
optional KRP1B PCB kit ON/OFF input from outside
(T1/T2 input) = Setting when
1
forced ON/OFF is to be operated from outside.
Fan setting during thermostat
3
OFF at heating operation
Differential automatic
4
changeover
Auto-restart after power failure Disabled Enabled
5
Fixed cool/heat master Disabled Enabled
9
Drain pump operation +
3
humidifier interlock
indoor units can also be set individually.
10-2-02 or 10-2-03 have priority.
connection, 10-6-01 has priority and for individual connection, 10-2-01, 10-2-02 or 10-2-03 have priority.
Second code No. 05 4°C
Ultra-long­life filter
Long-life filter
Standard filter
06 5°C 07 6°C 08 7°C
Second code No. (Note 2)
01 02 03 04
±10,000 hrs.
±2,500 hrs. ±1,250 hrs.
Light
±200 hrs. ±100 hrs.
Use both the unit sensor (or remote sensor if installed) AND the remote controller sensor. (See note 5+6)
Display Do not display —
Use unit sensor only (or remote sensor if installed). (See note 6)
Thermostat-on + compressor run
Forced OFF
LL Set speed
0°C 1°C 2°C
Equipped Not equipped
±5,000 hrs.
Heavy
Use unit sensor only (or remote sensor if installed). (See note 5+6)
Use both the unit senor (or remote sensor if installed) AND the remote controller sensor. (See note 4+5+6)
Operation
ON/OFF operation
——
Use remote controller sensor only. (See note 5+6)
——
——
OFF (See note 3)
Mal­function
3°C (See note 7)
FXSQ20~140P7VEB VRV System air conditioners 4PW56483-1
Installation and operation manual
8

External static pressure settings

Settings for external static pressure can be achieved in 2 ways:
Using the airflow automatic adjustment function
Airflow automatic adjustment is the volume of blow-off air that has been automatically adjusted to the rated quantity.
1 Make sure the test run is done with a dry coil.
If the coil is not dry, run the unit for 2 hours with fan only to dry the coil.
2 Check if the power supply wiring to the air conditioning unit is
completed along with the duct installation. If a closing damper is installed in the air conditioning unit, make
sure that it is open. Also check if the air filter is properly attached into the air passage on the air suction side of the air conditioning unit.
3 If there is more than one air inlet and outlet, adjust the dampers
so that the airflow rate of each air inlet and outlet is conform with the designed airflow rate.
Make sure the air conditioning unit is in fan operation mode. Press and set the airflow adjustment button on the remote controller to change the airflow rate to H or L.
4 Setting the airflow automatic adjustment settings.
When the air conditioning unit is running in fan operation mode perform the next steps:
- stop the air conditioning unit,
- go to field setting mode,
- select mode No. 21 (or 11 in case of group setting),
- set the first code No. to "7",
- set the second code No. to "03". Return to normal operating mode after setting these settings and press the ON/OFF operation button. The operation lamp will light up and the air conditioning unit will start the fan operation for airflow automatic adjustment.
Do not adjust the dampers during fan operation for airflow automatic adjustment.
After 1 to 8 minutes, the air conditioning unit stops operating automatically when the fan operation for airflow automatic adjustment has been carried out, the operation lamp will be off.
Mode
No.
11 (21) 7
5 When the air conditioning unit has stopped, check on an indoor
unit if the second code No. of mode No. 21 is set to "02". If the air conditioning unit does not stop operating or the second
code No. is not "02", repeat step 4. If the outdoor unit is not turned on, the display on the remote controller will show "U4" or "UH" (refer to "Test operation" on
page 10). However, you can continue setting this function
because these messages are only applicable to outdoor units. After setting this function, be sure to turn on the outdoor unit before performing the test operation on the outdoor unit. If any other error display occurs on the display of the remote controller, refer to "Test operation" on page 10 and the operation manual of the outdoor unit. Check the defective point.
First
code No.
Second
code No.
Setting content
01 Airflow adjustment is OFF 02 Completion of airflow adjustment 03 Start of airflow adjustment
If the external static pressure of the FXSQ140P7VEB is higher than 100 Pa, do not use airflow automatic adjustment function.
If there is no change after airflow adjustment in the ventilation paths, be sure to perform setting the airflow automatic adjustment again.
Contact your dealer if there is no change after performing airflow adjustment in the ventilation paths, after performing the test operation of the outdoor unit or when the air conditioning unit is moved to another location.
If booster fans, an outdoor air processing unit or HRV via duct are used, do not use airflow automatic adjustment control with a remote controller.
If the ventilation paths have been changed, perform the setting of the airflow automatic adjustment again as described above from step 3 onwards.
Using the remote controller
Check on an indoor unit if the second code of mode No. 21 is set to "01" (= factory setting). Change the second code according to the external static pressure of the duct to be connected as shown in table 2.
NOTE
The second code No. is set to "03" by default.
Ta ble 2
External static pressure (Pa)
FXSQ
Mode
No.
13
(23)
First code
No.
6
Second
code
No.
03 04 05 06 07 08 09 10 11 12 13
20 25 32 40 50 63 80 100 125 140
30 30 30 30 30 30 40 40 50 50 35 35 35 35 35 40 45 50 55 55 40 40 40 40 40 50 50 60 60 60 45 45 45 45 45 60 60 70 70 70 50 50 50 50 50 70 70 80 80 80 55 55 55 60 60 80 80 90 90 90 60 60 60 70 70 90 90 100 100 100 65 65 65 80 80 100 100 110 110 110 70 70 70 90 90 — 120 120 120 ———100100————130 —————————140

Control by 2 Remote Controllers (Controlling 1 indoor unit by 2 remote controllers)

When using 2 remote controllers, one must be set to "MAIN" and the other to "SUB".
MAIN/SUB CHANGEOVER
Insert a wedge-head screwdriver into the recess between the upper and lower part of the remote controller and, working from the 2 positions, pry off the upper part. (See figure 18) (The remote controller PC board is attached to the upper part of the remote controller.)
Tu rn the main/sub changeover switch on one of the two remote controller PC boards to "S". (See figure 19) (Leave the switch of the other remote controller set to "M".)
1 Remote controller PC board 2 Factory setting 3 Only one remote controller needs to be changed
Installation and operation manual
9
FXSQ20~140P7VEB
VRV System air conditioners
4PW56483-1

Computerised control (forced off and on/off operation)

1 Wire specifications and how to perform wiring
- Connect input from outside to terminals T1 and T2 of the terminal board (remote controller to transmission wiring).
Wire specification Sheathed vinyl cord or cable (2 wire)
Gauge
Length Max. 100 m External terminal Contact that can ensure the minimum
F2 T1 T2
FORCED OFF
Input A
0.75-1.25 mm
applicable load of 15 V DC, 10 mA
2
2 Actuation
- The following table explains "forced off" and "on/off operations" in response to input A.
Forced off on/off operation
Input "on" stops operation input off ➜ on: turns on the unit
Input "off" enables control input on ➜ off: turns off the unit by
(impossible by remote controllers)
remote controller
3 How to select forced off and on/off operation
-Turn the power on and then use the remote controller to select operation.
- Set the remote controller to the field set mode. For details, refer to the chapter "How to set in the field", in the remote controller manual.
- When in the field set mode, select mode No. 12, then set the first code No. to "1". Then set second code (position) No. to "01" for forced off and to "02" for on/off operation. (forced off at factory set.) (See figure 20)
1 Second code No. 2 Mode No. 3 First code No. 4 Field set mode

Centralized control

For centralized control, it is necessary to designate the group No. For details, refer to the manual of each optional controller for centralized control.

TEST OPERATION

Refer to the installation manual of the outdoor unit. The operation lamp of the remote controller will flash when an error
occurs. Check the error code on the liquid crystal display to identify the trouble.
Error code Meaning
A8 Error in power supply to indoor unit
C1
C6
U3 Test operation of the indoor unit has not been finished
Tr ansmission error between fan driver PCB and controller PCB of the indoor unit
Improper combination of fan driver PCB of the indoor unit or setting failure in control PCB type
If any of the items in following table are displayed on the remote controller, there may be a problem with the wiring or power, so check the wiring again.
Error code Meaning
There is a short circuit at the forced off terminals (T1, T2)
U4 or UH
no display
- The power on the outdoor unit is off
- The outdoor unit has not been wired for power supply
- Incorrect transmission of forced off wiring
- The power on the indoor unit is off
- The indoor unit has not been wired for power supply
- Incorrect transmission wiring, forced off wiring or remote controller wiring

MAINTENANCE

Caution
Only a qualified service person is allowed to perform maintenance.
Before obtaining access to terminal devices, all power supply circuits must be interrupted.
Do not use water or air of 50°C or higher for cleaning air filters and outside panels.
When cleaning the heat exchanger, be sure to remove the switchbox, fan motor, auxiliary electric heater and drain pump. Water or detergent may deteriorate the insulation of electronic components and result in burn-out of these components.
If the main power supply is turned off during operation, operation will restart automatically after the power turns back on again.

INSTALLATION OF THE DECORATION PANEL

Refer to the installation manual attached to the decoration panel. After installing the decoration panel, ensure that there is no space
between the unit body and decoration panel.
FXSQ20~140P7VEB VRV System air conditioners 4PW56483-1
How to clean the air filter
Clean the air filter when the display shows " " (TIME TO CLEAN AIR FILTER).
Increase the frequency of cleaning if the unit is installed in a room where the air is extremely contaminated.
If the dirt becomes impossible to clean, change the air filter. (Air filter for exchange is optional.)
1 Open the suction grille. (Only for bottom suction.)
Slide both knobs simultaneously as shown and then pull them downward.
Installation and operation manual
10
If chains are present, unhook the chains.
5 Shut the air inlet grille. (Only for bottom suction.)
Refer to item no. 1.
6 After turning on the power, press FILTER SIGN RESET button.
The "TIME TO CLEAN AIR FILTER" display is turned off.

How to clean air outlet and outside panels

2 Remove the air filters.
Remove the air filters by pulling their cloth upward (rear suction) or backward (bottom suction).
rear suction
bottom suction
3 Clean the air filter.
Use vacuum cleaner (A) or wash the air filter with water (B).
(A) Using a vacuum cleaner
(B) Washing with water
Clean with soft cloth.
When it is difficult to remove stains, use water of neutral
detergent.
Clean the air inlet grille when it is shut.
NOTE
Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide. It may cause discolouring or warping.
Do not let the indoor unit get wet. It may cause an electric shock or a fire.

Start up after a long stop

Confirm the following:
Check that the air inlet and outlet are not blocked. Remove any obstacle.
Check if the earth is connected.
Clean the air filter and outside panels.
After cleaning the air filter, make sure to attach it.
Tu rn on the main power supply switch.
The control panel display lights when the power is turned on.
To protect the unit, turn on the main power switch at least
6 hours before operation.

What to do when stopping the system for a long period

When the air filter is very dirty, use soft brush and neutral detergent. Remove water and dry in the shade.
4 Fix the air filter.
rear suction
bottom suction
Tu rn on FAN OPERATION for half a day and dry the unit.
Refer to the operation manual of the outdoor unit.
Cut off the power supply.
When the main power switch is turned on, some wattage is being consumed even if the system is not operating.
The remote controller display is turned off when the main power switch is turned off.

DISPOSAL REQUIREMENTS

Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in accordance with relevant local and national legislation.
Align the two hanger brackets and push the two clips in their place (pull the cloth if necessary). Confirm that four hangers are fixed.
Installation and operation manual
11
FXSQ20~140P7VEB
VRV System air conditioners
4PW56483-1

WIRING DIAGRAM

: FIELD WIRING BLK : BLACK ORG : ORANGE : CONNECTOR BLU : BLUE PNK : PINK : WIRE CLAMP BRN : BROWN RED : RED
: PROTECTIVE EARTH (SCREW) L: LIVE GRY : GREY YLW : YELLOW N: NEUTRAL
GRN : GREEN WHT : WHITE
A1P........................ PRINTED CIRCUIT BOARD
A2P........................ PRINTED CIRCUIT BOARD (FAN)
A3P........................ PRINTED CIRCUIT BOARD (CAPACITOR)
(only for 63~140 units)
C1,C2,C3............... CAPACITOR
F1U........................ FUSE (T, 3.15 A, 250 V)
F2U........................ FUSE (T, 5 A, 250 V)
F3U,F4U................ FUSE (T, 6.3 A, 250 V)
HAP ....................... LIGHT EMITTING DIODE
(SERVICE MONITOR - GREEN)
KPR,K1R ............... MAGNETIC RELAY
L1R........................ REACTOR
M1F ....................... MOTOR (FAN)
M1P ....................... MOTOR (DRAIN PUMP)
PS.......................... SWITCHING POWER SUPPLY
Q1DI ...................... EARTH LEAK DETECTOR
R1.......................... RESISTOR (CURRENT LIMITING)
R2.......................... CURRENT SENSING DEVICE
R3,R4 .................... RESISTOR (ELECTRIC DISCHARGE)
R1T........................ THERMISTOR (SUCTION AIR)
R2T........................ THERMISTOR (LIQUID)
R3T ........................THERMISTOR (GAS)
R5T ........................THERMISTOR NTC (CURRENT LIMITING)
S1L.........................FLOAT SWITCH
V1R........................DIODE BRIDGE
V2R........................POWER MODULE
X1M........................TERMINAL STRIP (POWER SUPPLY)
X2M........................TERMINAL STRIP (CONTROL)
Y1E ........................ELECTRONIC EXPANSION VALVE
Z1C,Z2C ................NOISE FILTER (FERRITE CORE)
Z1F.........................NOISE FILTER
CONNECTOR OPTIONAL ACCESSORY
X28A ......................CONNECTOR (POWER SUPPLY FOR WIRING)
X33A ......................CONNECTOR (FOR WIRING)
X35A ......................CONNECTOR (ADAPTOR)
X38A ......................CONNECTOR (FOR WIRING)
WIRED REMOTE CONTROLLER
R1T ........................THERMISTOR (AIR)
SS1 ........................SELECTOR SWITCH (MAIN/SUB)
WIRED REMOTE CONTROLLER : (OPTIONAL ACCESSORY) : SWITCH BOX (INDOOR) : TRANSMISSION WIRING : CENTRAL REMOTE CONTROLLER : INPUT FROM OUTSIDE :
NOTE
1. USE COPPER CONDUCTORS ONLY.
2. WHEN USING THE CENTRAL REMOTE CONTROLLER, SEE MANUAL FOR CONNECTION TO THE UNIT.
3. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED "OFF" OR "ON/OFF" CONTROL OPERATION CAN
BE SELECTED BY THE REMOTE CONTROLLER. SEE INSTALLATION MANUAL FOR MORE DETAILS.
FXSQ20~140P7VEB VRV System air conditioners 4PW56483-1
Installation and operation manual
12
NOTES NOTES
12
5
13
Control box
IN/D OUT/D
F
L N
4
1
1 F2 F1 F2
Control box
IN/DOUT/D
F
1 F2 F1 F2
1
6
23
P1P2F1F2T1T
12
14
L N
P1P
2
2
2
3
14
5
10
13
15
Control box
1
L N
IN/D OUT/D
F1 F2 F1 F2
L
L NL N
N
13
6 9
L N
811 6 7 12
14 15
16
1
2
3
4 5 6
7
8
9
L N L N L N L N
P1P
2
F1F2T1T
2
2
P1P
2
P1P2F1F2T1T
P1P
2
2
P1P2F1F2T1T
2
P1P2F1F2T1T
2
4
P1P
2
P1P
2
3
17
1
L N
2
3
Control box
IN/D OUT/D
F1 F2 F1 F2
L N
P1P
2
F1F2T1T
P1P
L N L N L N
2
P1P2F1F2T1T
2
P1P2F1F2T1T
2
P1P2F1F2T1T
2
4
P1P
P1P
2
2
2
5
16 17
18
19
2
S
S
M
3
S
M
18 19
20
21
1
3 4
SETTING
20
4PW56483-1