Daikin FXMQ40PVE, FXMQ50PVE, FXMQ63PVE, FXMQ80PVE, FXMQ100PVE Installation manuals [sv]

...
INSTALLATIONSHANDBOK
System
Inverterarluftkonditioneringsaggregat
FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE
FXMQ40PVE FXMQ80PVE FXMQ50PVE FXMQ100PVE FXMQ63PVE FXMQ125PVE
NNEHÅLL
I
Försiktighetsåtgärder ........................................................................ 1
Före installation................................................................................. 2
Att välja plats för installationen.......................................................... 4
Förberedelser före installation........................................................... 4
Installera inomhusenheten................................................................ 6
Anslutning av köldmediumrör............................................................ 6
Ansluta dräneringsrör........................................................................ 8
Luftkanal............................................................................................ 9
Elektriska kopplingar ....................................................................... 10
Kopplingsexempel och inställning av fjärrkontrollen........................ 11
Inställningar..................................................................................... 14
Testkörning...................................................................................... 15
LÄS DESSA INSTRUKTIONER NOGGRANT FÖRE INSTALLATIONEN.
SPARA MANUALEN PÅ LÄTTILLGÄNGLIG PLATS FÖR FRAMTIDA BRUK SOM REFERENS.
ÖRSIKTIGHETSÅTGÄRDER
F
Läs igenom dessa säkerhetsöverväganden noggrant före installation av luftkonditioneraren och var noggrann med att utföra installationen på rätt sätt.
När installationen är färdig genomför du en provdrift för att leta efter fel. Förklara för kunden hur luftkonditioneraren ska användas med hjälp av bruksanvisningen. Uppmana kunden att förvara installations­handboken tillsammans med bruksanvisningen för framtida behov.
Denna luftkonditioneringsanläggning lyder under beskrivningen "utrustning som ej är tillgänglig för allmänheten".
VRV System Inverterarluftkonditioneringsaggregat
Takmonterad luftkanaltyp
Sida

Försiktighetsåtgärder

Enheten är en A-klassad produkt. I en hushållsmiljö kan den här produkten orsaka radiostörningar och användaren måste då vidta lämpliga åtgärder.
Om du inte följer varningar som klassificerats som VARNING kan det resultera i dödsfall eller allvarliga skador.
Om du inte följer varningar som klassificerats som FÖRSIKTIGT kan det orsaka kroppsskador eller skador på utrustningen.
Installationshandbok
Varning
Låt leverantören eller kvalificerad personal utföra installationen. Försök inte installera luftkonditioneraren på egen hand. Felaktig installation kan orsaka vattenläcka, elektriska stötar eller eldsvåda.
Installera luftkonditioneraren enligt instruktionerna i denna installationshandbok. Felaktig installation kan orsaka vattenläcka, elektriska stötar eller eldsvåda.
Kontakta leverantören i händelse av ett köldmediumläckage. När luftkonditioneringsanläggningen ska installeras i ett litet rum måste åtgärder vidtas som förhindrar att köldmedium som läcker ut överskrider gränsvärdet i händelse av en läcka. Annars kan detta leda till en olycka orsakad av syrebrist.
Använd bara föreskrivna delar och tillbehör under installationen. Om de föreskrivna delarna inte används kan det orsaka vattenläcka, elektriska stötar, eldsvåda eller att enheten faller ned.
Installera luftkonditioneraren på ett fundament som klarar av tyngden. Ett otillräckligt fundament kan resultera i att utrustningen faller ned och orsakar kroppsskada.
Tag hänsyn till starka vindar, orkaner eller jordbävningar när du utför det angivna installationsarbetet. Felaktigt installationsarbete kan orsaka olyckor som en följd av att enheten faller ned.
Kontrollera att en separat strömkrets används för den här enheten och att allt elarbete utförs av behörig personal enligt lokala bestämmelser samt denna installationshandbok. Otillräcklig kapacitet i elkretsen eller felaktig elkonstruktion kan leda till elstötar eller eldsvåda.
Kontrollera att allt kablage är ordentligt anslutet, att föreskrivna kablar används och att ingen belastning finns på terminal­anslutningar eller kablar. Felaktig anslutning av kablarna kan leda till onormal hetta eller brand.
Vid koppling av strömförsörjningen samt anslutning av fjärr­kontroll och signalöverföring ska kablarna placeras så att locket till kopplingsboxen kan fästas ordentligt. Felaktig placering av locket till kopplingsboxen kan orsaka elektriska stötar, eldsvåda eller överhettade terminaler.
Om köldmediumångor läcker ut under installationsarbetet ska området ventileras omedelbart. Giftig gas kan produceras om köldmediet kommer i kontakt med eld.
När installationen är färdig kontrollerar do om något köldmedium läcker. Giftig gas kan produceras om köldmediumångor läcker in i rummet och kommer i kontakt med en värmekälla, t.ex. en värmefläkt, ugn eller spis.
Se till att stänga av enheten innan du vidrör några elektriska delar.
Se till att jorda luftkonditioneraren. Jorda inte enheten till ett vattenrör, en åskledare eller en jordledning för telefon. Felaktigt utförd jordning kan orsaka elektriska stötar eller eldsvåda. En kraftig strömstöt från ett blixtnedslag eller en annan källa kan skada luftkonditioneringsanläggningen.
Installera en jordfelsbrytare. Om en jordfelsbrytare saknas kan det leda till elektriska stötar eller eldsvåda.
Installationshandbok
1
VRV System Inverterarluftkonditioneringsaggregat
FXMQ40~125PVE
Takmonterad luftkanaltyp
4PW45578-3
Försiktigt
Följ instruktionerna i den här installationshandboken och installera dräneringsrören för korrekt dränering. Isolera sedan rören för att förhindra kondens. Felaktig installation av dräneringsrör kan orsaka vattenläckor och sakskador inomhus.
Installera inomhus- och utomhusenheterna, strömsladden och anslutningskabeln minst 1 meter från TV- eller radioapparater för att förhindra bildstörningar eller brus. (Beroende på signalstyrkan kan ett avstånd på 1 meter vara otillräckligt för att eliminera bruset.)
Den trådlösa fjärrkontrollens räckvidd kan vara kortare än väntat i rum med elektroniskt startade lysrör. Placera inomhusenheten så långt bort som möjligt från lysrörsarmaturer.
Installera inte luftkonditioneraren på följande platser.
Där det finns hög koncentration av mineralolja, oljespray eller ånga, t.ex. ett kök. Plastdelar kommer att skadas, delar kan ramla av och vattenläckor kan uppstå.
Där frätande gas, t.ex. gas av svavelhaltig syra, produceras. Korrosion av kopparrören eller lödda delar kan göra att köldmediet läcker ut.
Nära maskiner som avger elektromagnetisk strålning. Elektromagnetisk strålning kan störa driften av styrsystemet och göra att enheten inte fungerar som den ska.
Där brandfarlig gas kan läcka ut, där kolfiber eller lättantändligt damm finns i luften eller där brandfarliga ämnen som thinner eller bensin hanteras. Drift under sådana förhållanden kan orsaka eldsvåda.
1
2
Platser där salthalten i luften är hög, t.ex. platser nära havet, samt där spänningsvariationerna är stora, t.ex. i vissa fabriker. Detta gäller även båtar och bilar.
Både inomhus- och utomhusenheterna är anpassade för att installeras både i offentlig miljö och i lätt industrimiljö. Vid installation i hemmiljö kan det medföra elektromagnetiska störningar.

Försiktighetsåtgärder

Läs igenom den här handboken noggrant innan du påbörjar installationen av inomhusenheten.
Installationen bör skötas av återförsäljaren eller en kvalificerad servicetekniker. Felaktig installation kan leda till läckor, eller i värsta fall elektriska stötar eller brand.
Använd endast delar som medföljde enheten eller som uppfyller specifikationerna. Användning av andra delar kan orsaka att enheten faller, börjar läcka eller i värsta fall till elektriska stötar eller brand.
Montera ett luftfilter (införskaffas lokalt) i luftintagspassagen för att förhindra vattenläckor osv.

Tillbehör

Kontrollera att följande tillbehör levererats med enheten. Se bilden nedan för tillbehörens placering.
1
F
ÖRE
INSTALLATION
När du lyfter ut enheten ur förpackningen ska du hålla den i de fyra lyftöglorna och inte påfresta några andra delar, särskilt köldmediumrör, dräneringsrör och andra plastdetaljer
Kontrollera vilken typ av R410A-köldmedium som ska användas
.
innan du installerar enheten. (Om du använder fel köldmedium fungerar enheten kanske inte som normalt.)
De tillbehör som krävs för installationen måste du förvara tills installationen är slutförd. Kasta inte bort dem!
Bestäm dig för en transportväg.
Packa inte upp enheten förrän den är framme vid installations­platsen. Om det är nödvändigt att packa upp den tidigare bör enheten lyftas med en mjuk lina eller med rep och skyddsplattor för att inte enheten ska skadas eller repas.
När du flyttar enheten vid eller efter öppning ska du hålla den i upphängningsbultarna (x4). Lägg inget tryck på köldmediumrör, dräneringsrör, flänsar eller plastdelar.
För installation av utomhusenheten, se installationshandboken som medföljer denna.
Installera eller använd inte enheten i sådana utrymmen som anges nedan.
Platser med mineraloljor, oljedimma eller ångor som t.ex. kök. (Plastdelar kan försvagas, vilket kan leda till att enheten faller eller börjar läcka.)
Platser med korroderande gas, t.ex. svavelångor. (Kopparrör och hårdlödda områden kan oxidera, vilket kan leda till köldmediumläckor.)
Platser där brännbara eller brandfarliga, instabila gaser som thinner eller bensin används. (Gas i närheten av enheten kan antändas.)
Platser med maskiner som kan avge elektromagnetiska fält. (Kan medföra att styrsystemen sätts ur funktion.)
2
Tillbehör Installations- och användarhandbok
Försiktighetsåtgärd
Tillbehören krävs för installation av luftkonditioneraren. Se till att spara dem tills installationen är färdig.
Metallklämma 1
Dräneringsslang 1
Isolering för rör:
• för gasledning (tjock)
• för vätskeledning (tunn)
Tätning
• Stor (mörkgrå)
• Medelstor (mörkgrå)
Klämma 9
Skruvar för kanalflänsar
Bricka 8
1
1
1
2
(*)
10
(**)
18
(***)
26
FXMQ40~125PVE
VRV System Inverterarluftkonditioneringsaggregat Takmonterad luftkanaltyp
4PW45578-3
Installationshandbok
2
Fixeringsplåt för bricka 4
Kabeltätningsmaterial (liten)
2
(grå)
Kabelfästkonsol 2
Kabelfästskruv 2
Installationshandbok Användarhandbok
(*) För FXMQ40. (**) För FXMQ50~80. (***) För FXMQ100+125.
L
L
A
A
U
U
N
N
A
A
M
M
N
N
O
O
I
I
T
T
A
A
s
L
R
r
s
L
E
r
e
A
P
e
n
T
n
o
O
S
i
s
o
t
N
i
r
i
s
I
t
r
e
i
d
e
n
d
n
n
o
n
o
i
o
o
t
c
i
i
t
c
r
i
d
i
r
d
n
i
a
n
o
a
o
c
m
c
m
r
o
i
r
o
o
i
a
r
o
a
r
s
m
s
e
m
o
i
e
r
o
o
i
r
r
e
o
s
r e s
m t i
e l
t
p
s
S
y s i t l
u
M
1 V
7
B 5 2 Q
B D
F
h
h
s
s
i
i
l
l
m
t
g
g
i
n
n
e
l
E
E
t
p
s
l
l
S
a
a
y
u
u
n
n
s
a
a
m
m
i
s
s
n
n
r
r
t
o
o
e
e
i
i
l
t
t
n
n
a
a
o
o
l
l
i
i
l
l
u
t
t i
i
a
a
t
t
d
d
s
s
n
n
h
h
n
n
M
o
o
I
I
c
c
c
c
s
s
t
t
r
r
i
i
u
u
e
e
a
a
D
D
m
m
e
e
t
t
s
s
g
g
y
y
n
n
S
S
u
u
t
t
t
t
i
i
i
i l
l
e
e l
l
p
p
n
n
S
S
e
e
a
a
t
t
s
s
ä
ä
r
r
n
n
e
e
o
o
i
i
t
t
g
g
a
a
a
a
l
l
l
l
m
m
a
a
i
i
s
s
t
t
l
l
i
i
s
s
a
a
K
K
ç
ç
n
n
I
I
n
n
e
e
a
a
h
h
r
r
i
i
F
F
e
e
r
r
u
u
a
a
n
n
B
B
-
­o
o
t
t
i
i
i
i
t
t
l
l
a
a
p
p
l
l
l
l
S
S
a
a
t
t
t
t i
i
s
s
l
l
n
n
p
p
i
i '
'
S
S
d
d l
l
e
e
i
i
e
e
r
r
u
u
é
é
n
n
s
s
s
s
a
a
d
d
a
a
n
n
l
l
M
M
a
a
l
l
e
e
r
r
d
d
e
e
d
d
s
s
e
e
r
r
N
N
u
u
e
e
g
g
s
s
i
i
n
n
t
t
i
i
a
a
d
d
i
i
m
m
e
e
i
i
l
l
l
l
d
d
C
C
s
s
n
n
r
r
a
a
e
e
h
h
n
n
e
e
o
o
i
i
g
g
t
t
i
i
a
a
t
t
d
d
l
l
n
n
n
n
o
o
o
o
o
o
ñ
ñ
c
c
a
a
M
M
r
r
i
i
p
p
a
a
s
s
E
E
m
m
e
e
e
e
t
t
n
n
s
s
y
y
ó
ó
i
i
s
s
c
c
-
-
t
t
a
a
i
i
l
l
l
l
a
a
p
p
t
t
t
t
i
i
S
S
s
s
l
l
n
n
p
p
i
i
S
S
e
e
e
e
d
d
i
i
l
l
r
r
a
a
e
e
s
s
u
u
o
o
n
n
n
n
e
e
a
a
a
a
r
r
i
i
i
i
l
l
a
a
a
a
M
M
t
t I
I
e
e
d
d
s
s
e
e
r
r
e
e
o
o
n
n
d
d
o
o
i
i
a
a
z
z
n
n
a
a
l
l
o
o
l
l
i
i
t
t i
i
c
c
a
a
l
l
i
i
t
t
p
p
d
d
s
s
n
n
S
S
n
n
i
i
'
'
o
o
e
e
d
d
c
c
i
i r
r
A
A
e
e
e
e
l
l
s
s
¿
¿
a
a
Î
Î
i
i
È
È
u
u
r
r
Ó
Ó
n
n
o
o
Ë
Ë
t
t
a
a
Ï
Ï
a
a
Ï
Ï
M
M
z
z
∂
∂
z
z i
i
t
t
a
a
˜
˜
m
m i
i
l
l
Ë
Ë
Û
Û
C
C
·
· Ù
Ù
Û
Û
t
t
i
i
¿
¿
l
l
Ù
Ù
p
p
·
· S
S
Î
Î Á
Á
¿
¿
Â
Â
Î
Î È
È
Ù
Ù
Ô
Ô
s
s
È
È
e
e
Û
Û
È
È
u
u
Ù
Ù
g
g
Ú
Ú
È
È
·
·
u
u
t
t
Â
Â
Ì
Ì
r
r
È
È
¯
¯
o
o
Ï
Ï
Á
Á
P
P
K
K
E
E
o
o
ã
ã
ç
ç
a
a
l
l
a
a
t
t
t
t
s
s
i
i
l
l
n
n i
i
p
p
S
S
e
e
d
d
e
e
i
i
l
l
r
r
a
a
é
é
u
u
k
k
s
s
s
s
n
n
n
n
a
a
a
a
a
a
d
d
M
M
D
D
o
o
d
d
a
a
n
n
o
o
i
i
g
g
c
c
i
i
n
n
i
i
d
d
n
n
n
n
d
d
o
o
c
c
e
e
l
l
j
j
r
r
e
e
a
a
m
m
v
v
e
e
e
e
t
t
s
s
s
s
d
d
n
n
y
y
o
o
s
s
i
i
s
s
t
t
o
o
t
t
a
a
l
l
l
l
h
h
l
l
l
l
e
e
a
a
e
e
d
d
t
t
r
r
p
p
s
s
a
a
o
o
n
n
p
p
I
I
i
i
A
A
g
g
a
a
l
l
n
n
a
a
a
a
m
m
i
i
l
l
K
K
1 V 7
B 5 2 Q
B D
F
1

Extra tillbehör

Det finns två typer av fjärrkontroller: trådlösa och kabelanslutna. Välj fjärrkontroll från Tabell 1, beroende på kundens önskemål och installera den på lämplig plats.
Tabell 1
Fjärrkontrolltyp Kylanläggningar Värmepumpstyp
Kabeltyp Trådlös typ
OBS!
Om du vill använda en fjärrkontroll som inte finns med i
"Tabell 1" på sid 3 väljer du en lämplig fjärrkontroll med
hjälp av kataloger och tekniskt material.

Följande punkter måste utföras extra noggrant och kontrolleras efter installation

Följande ska kontrolleras efter slutfört arbete
Pricka av när
kontroll utförts
Har inomhus- och
utomhusenheterna fästs ordentligt?
Är installationen av
utomhusenheten slutförd?
Är kontroll av gastäthet klar? Ingen kylning eller
Är enheten helt isolerad?
(köldmediumrör, dräneringsrör och luftkanaler)
Fungerar dräneringen som
den ska? Stämmer matnings-
spänningen med vad som anges på märkplåten?
Är elektriska ledningar och rör
anslutna som de ska?
Är enheten riktigt jordad? Läckströmmar är farliga.
Är rätt kabeldimensioner
använda?
Är inom- och
utomhusenheternas luftintag och luftutsläpp fria från blockering?
Har du ställt in det yttre
statiska trycket? Har kylrörens längd och
tillsats av extra köldmedium antecknats?
Kontrollerade du att inga
kabelanslutningsskruvar sitter löst?
Enheterna kan falla ned, vibrera eller föra oljud.
Enheten kan sluta fungera och komponenter kan brännas sönder.
uppvärmning. Kondensvatten kan droppa ned.
Kondensvatten kan droppa ned.
Enheten kan sluta fungera och komponenter kan brännas sönder.
Enheten kan sluta fungera och komponenter kan brännas sönder.
Enheten kan sluta fungera och komponenter kan brännas sönder.
Ingen kylning eller uppvärmning.
Ingen kylning eller uppvärmning.
Det är oklart hur mycket köldmedium som finns i systemet.
Elstötar eller brand.
Kontrolleras vid leverans
Pricka av när kontroll utförts
Är du säker på att locket till reglerboxen, luftfiltret,
luftintagsgallret och luftutloppsgallret monterats? Har du förklarat hur användningen går till medan du visat
kunden användarhandboken? Lämnade du bruksanvisningen till kunden tillsammans med
installationshandboken? Förklarade du för kunden hur lokalt anskaffade tillbehör ska
hanteras och rengöras (till exempel luftfilter, luftintagsgaller och luftutloppsgaller)?
Lämnade du eventuell bruksanvisning för lokalt anskaffade
tillbehör till kunden?
Punkter för förklaring av användningen
De punkter som markerats VARNING och FÖRSIKTIGT i användar­handboken är de punkter som gäller risk för kroppsskada och materiella skador förutom den allmänna användningen av produkten. Därför är det viktigt att i detalj förklara det beskrivna innehållet och dessutom be kunderna att läsa användarhandboken.

Information till installatören

Ge kunderna grundliga instruktioner i korrekt hantering av enheten (särskilt rengöring av filter, styrning av olika funktioner och justering av temperaturen) genom att låta dem utföra dessa funktioner själva med hjälp av handboken.
Installationshandbok
3
VRV System Inverterarluftkonditioneringsaggregat
FXMQ40~125PVE
Takmonterad luftkanaltyp
4PW45578-3
A
TT
VÄLJA
Håll enheten i upphängningsbultarna om du måste flytta inomhus­och utomhusenheterna när förpackningen är öppnad. Använd inte onödigt mycket belastning på andra delar, till exempel köldmedium­rör, dräneringsrör eller flänsar.
Värmeisolera inomhusenheten om temperaturen ovanför taket förväntas vara över 30°C och den relativa luftfuktigheten över 80 %.
Kontrollera att isoleringsmaterialet är gjort av glasull eller polyetylen­skum, har en minsta tjocklek på 10 mm och får plats i taköppningen.
Välj en installationsplats som uppfyller följande krav och som även passar kundens önskemål.
PLATS
En plats där kall (varm) luft kan spridas i hela rummet. Där inget blockerar luftcirkulationen. Där kondensvatten kan ledas bort på lämpligt sätt. Om strukturen inte kan bära enhetens vikt kan enheten falla
och orsaka allvarliga skador. Där innertakets lutning är obetydlig. Där det inte finns risk för läckor av brandfarliga gaser. Där tillräckligt utrymme för underhåll och service kan
tillgodoses.
2
FÖR
INSTALLATIONEN
620
*H2
*H1300
300
2500
450
FÖRSIKTIGT
Installera inomhus- och utomhusenheterna, strömsladden och anslutningskablar minst 1 meter från TV- eller radioapparater för att förhindra bildstörningar eller brus. (Beroende på radiovågorna kan ett avstånd på 1 meter vara otillräckligt för att eliminera bruset.)
Om du installerar med en trådlös fjärrkontroll kan fjärrkontrollens räckvidd minskas om det finns lysrörsbelysning i rummet. Se till att avståndet mellan mottagaren och lysröret är så stort som möjligt.
Använd upphängningsbultar när du installerar inomhusenheten. Kontrollera att installationsplatsen klarar inomhusenhetens tyngd. Säkra upphängningsbultarna med stolpar vid behov.
F
ÖRBEREDELSER
Kontrollera placeringen av hålen i taket i förhållande till enhetens upphängningsbultar.
Förbered något av följande utrymmen för underhåll, inspektion och annan service av reglerboxen och dräneringspumpen.
1. Inspektionslucka 1 (450x450) för reglerboxen och ett
minsta utrymme på 300 mm för produktens nederdel.
FÖRE
INSTALLATION
2
*H3=300
1.
2.
1.
700
1
1 Golvyta 2 Ta k
OBS!
Där rören mellan utom- och inomhusenheterna inte blir längre än vad som är tillåtet. (Se utomhusenhetens installationshandbok.)
H1-måtten visar produktens höjd.
Fastställ H2-måttet genom att ordna en
nedåtgående lutning på minst 1/100 enligt
"Ansluta dräneringsrör" på sid 8.
Måtten visar det minsta installationsutrymme som krävs.
1
700 631
4
57
6
9
1 Inspektionslucka 2 Reglerbox 3 Ta k 4 Avstånd mellan upphängningsbultar 5 Luftutlopp 6 Enhetens nederdel 7 Luftintag 8 Inspektionslucka 1 (450x450) 9 Upphängningsbult (x4)
3
8
2
B
C
4
FXMQ40~125PVE
VRV System Inverterarluftkonditioneringsaggregat Takmonterad luftkanaltyp
4PW45578-3
Installationshandbok
4
2. Inspektionslucka 1 (450x450) för reglerboxen och inspektionslucka 2 för produktens underdel (se axelriktning vy A). Måtten B, C och D finns i tabellen nedan.
1
3
*H320
2
A-1
A
4
5
200B
3
700
1 Inspektionslucka (taköppning) 2 Inspektionslucka 3 Reglerbox 4 Ta k 5 Inspektionslucka 1 (450x450) 6 Inspektionslucka 2
6
3. Inspektionslucka 3 för underdelen av produkten och
nederdelen av reglerboxen (se axelriktningsvy A-2). Måtten B, C och D finns i tabellen nedan.
1
3
Fastställ H3-måttet genom att ordna en nedåtgående lutning på minst 1/100 enligt "Ansluta dräneringsrör" på sid 8.
2. Installera de flexibla luftkanalerna vid luftutloppet och luftintaget så att luftkonditionerarens vibrationer inte överförs till luftkanalen eller innertaket. Använd ett ljudisolerande material (isolerings­material) på luftkanalens innervägg samt vibrationsdämpande gummi vid upphängningsbultarna (se "Luftkanal" på sid 9).
3. Öppna installationshål (om det redan finns innertak).
Ta upp installationshål i taket. Dra köldmediumrör,
dräneringsrör, strömkabel, ledningar för signalöverföring och fjärrkontrollkabeln till enhetens rör- och kabelanslutningsportar. Mer information om installation av trådlös fjärrkontroll finns i installationshandboken som medföljer den trådlösa fjärrkontrollen. Se "Anslutning av köldmediumrör" på sid 6, "Ansluta
dräneringsrör" på sid 8 och "Kopplingsexempel och inställning av fjärrkontrollen" på sid 11.
Tak et kan behöva förstärkas för att innertaket ska hållas
vågrätt samt för att förhindra vibrationer i innertaket efter att installationshålen har gjorts. Mer information kan du få av byggaren eller inredningsentreprenören.
4. Installera upphängningsbultarna. Kontrollera att de är av storlek M10.
Använd hålförankring om det redan finns upphängningsbultar. Annars använder du nedsänkta inlägg eller förankringsbultar så att de klarar enhetens vikt. Anpassa avståndet till innertaket i förväg.
1
2 3
5
1 Takskiva 2 Balk 3 Lång mutter eller spännskruv 4 Upphängningsbult 5 Inomhusenhet
4
*H320
2
A
4
A-2
3
5
D=B+300
700
1 Inspektionslucka (taköppning) 2 Inspektionslucka 3 Reglerbox 4 Ta k 5 Inspektionslucka 3
Modell B C D
FXMQ40 700 738 1000 FXMQ50~80 1000 1038 1300 FXMQ100+125 1400 1438 1700
OBS!
Alla komponenter ovan ingår i fältförrådet.
Installationshandbok
5
VRV System Inverterarluftkonditioneringsaggregat
FXMQ40~125PVE
Takmonterad luftkanaltyp
4PW45578-3
Loading...