1.1Informācija par dokumentāciju ......................................................................................................................................4
1.1.1Brīdinājumu un simbolu nozīme ....................................................................................................................4
1.2.2Uzstādīšanas vieta ..........................................................................................................................................6
2.1Par šo dokumentu........................................................................................................................................................... 14
3.1Pārskats. Informācija par iepakojumu ............................................................................................................................ 16
5.2Uzstādīšanas vietas sagatavošana .................................................................................................................................. 19
5.2.1Iekštelpās ievietojamās iekārtas uzstādīšanas vietas prasības ...................................................................... 19
6.4.5Caurules gala paplašināšana .......................................................................................................................... 32
6.4.6Dzesējošās vielas cauruļu pievienošana iekštelpu iekārtai............................................................................ 33
6.6Iekštelpu iekārtas uzstādīšanas pabeigšana................................................................................................................... 37
Uzstādītāja uzziņu grāmata
2
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin telpu gaisa kondicionētājs
4P513661-8H – 2019.12
Saturs
6.6.1Drenāžas cauruļvada, aukstumaģenta cauruļvada un savienotājkabeļa izolēšana....................................... 37
6.6.2Cauruļvadu ievilkšana sienas urbumā ............................................................................................................ 38
6.6.3Bloka piestiprināšana uz montāžas plates ..................................................................................................... 38
8.2Kontrolsaraksts pirms nodošanas ekspluatācijā............................................................................................................. 42
▪ Oriģinālā dokumentācija ir rakstīta angļu valodā. Pārējās valodās ir oriģinālo
dokumentu tulkojumi.
▪ Šajā dokumentā aprakstītie drošības pasākumi attiecas uz ļoti svarīgām tēmām
un ir rūpīgi jāievēro.
▪ Sistēmas uzstādīšana un visas darbības, kas aprakstītas uzstādīšanas
rokasgrāmatā un uzstādītāja uzziņu rokasgrāmatā, JĀVEIC pilnvarotam
uzstādītājam.
1.1.1 Brīdinājumu un simbolu nozīme
BĪSTAMI!
Norāda situāciju, kas izraisa nāvi vai nopietnu savainošanos.
BĪSTAMI! ELEKTROTRIECIENA SAŅEMŠANAS RISKS
Norāda situāciju, kas var izraisīt elektrotrieciena saņemšanu.
BĪSTAMI! APDEGUMU GŪŠANAS RISKS
Norāda situāciju, kas var izraisīt apdegumu gūšanu ļoti augstas vai zemas
temperatūras iedarbības rezultātā.
BĪSTAMI! EKSPLOZIJAS IZRAISĪŠANAS RISKS
Norāda iespējami sprādzienbīstamu situāciju.
BRĪDINĀJUMS
Norāda situāciju, kas var izraisīt nāvi vai nopietnu savainošanos.
BRĪDINĀJUMS: VIEGLI UZLIESMOJOŠS MATERIĀLS
UZMANĪBU!
Norāda situāciju, kas var izraisīt nāvi vai arī vieglu vai vidēji smagu savainošanos.
Uzstādītāja uzziņu grāmata
4
PAZIŅOJUMS
Norāda situāciju, kas var izraisīt aprīkojuma vai īpašuma bojājumus.
INFORMĀCIJA
Norāda noderīgus padomus vai papildinformāciju.
Uz iekārtas izmantotie simboli:
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin telpu gaisa kondicionētājs
4P513661-8H – 2019.12
SimbolsPaskaidrojums
Dokumentācijā izmantotie simboli:
SimbolsPaskaidrojums
1.2 Informācija uzstādītājam
1 | Vispārīgas drošības piesardzības pasākumi
Pirms uzstādīšanas izlasiet uzstādīšanas un ekspluatācijas
rokasgrāmatu, kā arī elektriskās shēmas instrukciju.
Pirms apkopes un servisa darbu veikšanas izlasiet apkopes
rokasgrāmatu.
Plašāku informāciju skatiet uzstādītāja un lietotāja uzziņu
rokasgrāmatā.
Norāda attēla nosaukumu vai atsauci uz to.
Piemērs: " 1–3 att." nozīmē "3.attēls 1.nodaļā".
Norāda tabulas nosaukumu vai atsauci uz to.
Piemērs: " 1–3 tab." nozīmē "3.tabula 1.nodaļā".
1.2.1 Vispārīgi
Ja neprotat uzstādīt vai lietot iekārtu, tad vērsieties pie izplatītāja.
BĪSTAMI! APDEGUMU GŪŠANAS RISKS
▪ Darbības laikā un uzreiz pēc tās neskarieties pie dzesētāja caurulēm, ūdens
caurulēm un iekšējām daļām. Tās var būt pārāk karstas vai pārāk aukstas.
Nogaidiet, līdz to temperatūra atgriezīsies normas robežās. Ja tomēr
nepieciešams tām pieskarties, valkājiet aizsargcimdus.
▪ NEPIESKARIETIES noplūdušam dzesētājam.
BRĪDINĀJUMS
Nepareiza aprīkojuma vai piederumu uzstādīšana var izraisīt elektrotriecienu,
īssavienojumu, noplūdes, aizdegšanos vai citādi bojāt aprīkojumu. Izmantojiet tikai
piederumus, papildaprīkojumu un rezerves daļas, kuras ražojis vai apstiprinājis
uzņēmums Daikin.
BRĪDINĀJUMS
Nodrošiniet, lai uzstādīšana, pārbaudes un izmantotie materiāli atbilstu piemērojamo
likumdošanas aktu prasībām (papildus Daikin dokumentācijā aprakstītajām
instrukcijām).
Veicot ierīces uzstādīšanu, apkopi vai remontu, izmantojiet atbilstošu personas
aizsargaprīkojumu (aizsargcimdus, aizsargbrilles utt.).
BRĪDINĀJUMS
Noplēsiet un izmetiet plastmasas iepakojuma maisiņus, lai ar tiem neviens
nespēlētos, it īpaši bērni. Pretējā gadījumā iespējams nosmakšanas risks.
Uzstādītāja uzziņu grāmata
5
1 | Vispārīgas drošības piesardzības pasākumi
BRĪDINĀJUMS
Veiciet atbilstošus pasākumus, lai nepieļautu to, ka iekārtu kā patvērumu izmanto
nelieli dzīvnieki. Nelieli dzīvnieki, saskaroties ar elektriskajām daļām, var izraisīt
nepareizu darbību, dūmošanu vai aizdegšanos.
UZMANĪBU!
NEAIZTIECIET iekārtas gaisa ievadu un alumīnija ribas.
UZMANĪBU!
▪ Uz iekārtas augšējās virsmas NENOVIETOJIET nekādus objektus un aprīkojumu.
▪ NESĒDIET, NEKĀPIET un NESTĀVIET uz iekārtas.
PAZIŅOJUMS
Lai ārpus telpām uzstādāmajā iekārtā neiekļūtu ūdens, darbus ir ieteicams veikt sausā
un skaidrā laikā.
Saskaņā ar attiecīgiem likumdošanas aktiem var būt nepieciešams līdz ar
izstrādājumu piegādāt žurnālu, kas satur vismaz šādas ziņas: informāciju par
apkopi, remontu, pārbaudes rezultātiem, dīkstāves periodiem utt.
Pieejamā vietā uz izstrādājuma JĀBŪT sniegtai arī šādai informācijai:
▪ Instrukcija par sistēmas izslēgšanu ārkārtas gadījumos.
▪ Ugunsdzēsēju, policijas un slimnīcas nosaukums un adrese.
▪ Pakalpojuma kontaktdati— nosaukums, adrese, diena sun nakts tālruņa numuri.
Instrukcija par šāda žurnāla sastādīšanu ir iekļauta Eiropas standartāEN378.
1.2.2 Uzstādīšanas vieta
▪ Ap iekārtu atstājiet pietiekami daudz brīvas vietas, lai nodrošinātu gaisa
cirkulāciju un varētu veikt iekārtas remontu.
▪ Pārliecinieties, ka virsma uz kuras veic uzstādīšanu, izturēs iekārtas svaru un
vibrāciju.
▪ Gādājiet, lai telpā būtu laba ventilācija. NEDRĪKST aizsegt ventilācijas atveres.
▪ Nodrošiniet, lai iekārta būtu nolīmeņota.
NEUZSTĀDIET iekārtu tālāk minētajās vietās.
▪ Vietās, kur pastāv potenciāli sprādzienbīstama atmosfēra.
▪ Vietās, kur atrodas mašinērija, kas izdala elektromagnētiskos viļņus.
Elektromagnētiskie viļņi var traucēt vadības sistēmai un izraisīt aprīkojuma
darbības traucējumus.
Uzstādītāja uzziņu grāmata
6
▪ Vietās, kur pastāv aizdegšanās risks uzliesmojošu gāzu noplūdes (piemēram,
krāsas šķīdinātāja vai benzīna iztvaikojumi), oglekļa šķiedru un uzliesmojošu
putekļu klātbūtnes dēļ.
▪ Vietās, kur rodas korozīvas gāzes (piemēram, sērskābes gāze). Vara cauruļu vai
lodēto savienojumu korozija var izraisīt dzesētāja noplūdes.
▪ Vannas istabās.
Instrukcija iekārtai ar aukstumaģentuR32
Ja tiek izmantots.
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin telpu gaisa kondicionētājs
4P513661-8H – 2019.12
1 | Vispārīgas drošības piesardzības pasākumi
Contains fluorinated greenhouse gases
2
1
1
1
2
2
kg
tCO2eq
1000
GWP × kg
=
=
+
kg
=
kg
=
GWP: xxx
R32
BRĪDINĀJUMS
▪ Nedurt un nededzināt.
▪ Atkausēšanas procesa paātrināšanai neizmantojiet nekādus citus līdzekļus,
izņemot ražotāja ieteiktos.
▪ Ņemiet vērā, ka aukstumaģentsR32 ir BEZ smaržas.
BRĪDINĀJUMS
No mehāniskiem bojājumiem pasargātu iekārtu uzglabā labi vēdināmā telpā, kur nav
aizdegšanās avotu (piemēram, atklātas liesmas, gāzes iekārtas vai elektriskā sildītāja,
kas pastāvīgi darbojas); telpas izmēriem jābūt atbilstošiem tālāk minētajiem.
PAZIŅOJUMS
▪ NEDRĪKST otrreiz izmantot iepriekš lietotus savienojumus.
▪ Dzesēšanas sistēmas uzstādīšanas laikā izveidotajiem savienojumiem ir jābūt
pieejamiem apkopei.
BRĪDINĀJUMS
Pārliecinieties, ka uzstādīšana, apkope un remonts atbilst Daikin instrukcijām un
attiecīgiem tiesību aktiem (piemēram, valsts noteikumiem par gāzes izmantošanu) un
ka šos darbus veic tikai pilnvarots personāls.
Uzstādīšanas vietas prasības
PAZIŅOJUMS
▪ Caurulēm jābūt aizsargātām pret mehāniskiem bojājumiem.
▪ Jāuzstāda pēc iespējas īsāki cauruļvadi.
BRĪDINĀJUMS
Ja iekārtā ir aukstumaģentsR32, tad telpā, kur iekārta ir uzstādīta, tiek ekspluatēta un
uzglabāta, grīdas platībai JĀBŪT lielākai par minimālo grīdas platību, kāda norādīta
tabulā zem A (m2). Tas attiecas uz:
▪ Iekšējiem blokiem bez aukstumaģenta noplūdes devēja; ja iekšējie bloki ir ar
aukstumaģenta noplūdes devēju, tad sk.uzstādīšanas rokasgrāmatu.
▪ Ārējo bloku, kas uzstādīts vai glabājas telpā (piem., ziemas dārzā, garāžā,
mašīntelpā).
▪ Cauruļvadiem vietās, kur trūkst ventilācijas.
Minimālās grīdas platības noteikšana
1Nosakiet kopējo aukstumaģenta daudzumu sistēmā (= rūpnīcā uzpildītais
aukstumaģents + papildus uzpildītais aukstumaģents).
▪ Iekšējam blokam: Vai iekārta uzstādīta pie griestiem, pie sienas vai uz grīdas?
▪ Ārējam blokam, kas uzstādīts vai glabājas telpā, un ārējam cauruļvadam
vietās bez ventilācijas tas ir atkarīgs no uzstādīšanas augstuma:
Ja uzstādīšanas augstums ir…Tad izmantojiet grafiku vai tabulu…
<1,8mBloks uzstādīts uz grīdas
1,8≤x<2,2mBloks uzstādīts pie sienas
≥2,2mBloks uzstādīts pie griestiem
3Izmantojiet grafiku vai tabulu, lai noteiktu minimālo grīdas platību.
Uzstādītāja uzziņu grāmata
8
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin telpu gaisa kondicionētājs
4P513661-8H – 2019.12
1 | Vispārīgas drošības piesardzības pasākumi
Ceiling-mounted
unit
(a)
4.613.4
4.6180
4.814.6
4.8196
5.015.8
5.0213
≤1.842—
5.217.1
≤1.842—
5.2230
1.8433.64
5.418.5
1.84328.9
5.4248
2.03.95
5.619.9
2.034.0
5.6267
2.24.34
5.821.3
2.241.2
5.8286
2.44.74
6.022.8
2.449.0
6.0306
2.65.13
6.224.3
2.657.5
6.2327
2.85.53
6.425.9
2.866.7
6.4349
3.05.92
6.627.6
3.076.6
6.6371
3.26.48
6.829.3
3.287.2
6.8394
3.47.32
7.031.0
3.498.4
7.0417
3.68.20
7.232.8
3.6110
7.2441
3.89.14
7.434.7
3.8123
7.4466
4.010.1
7.636.6
4.0136
7.6492
4.211.2
7.838.5
4.2150
7.8518
4.412.3
7.95640.1
4.4165
7.956539
m (kg)
A
min
(m2)
4.620.0
4.821.8
5.023.6
≤1.842—
5.225.6
1.8434.45
5.427.6
2.04.83
5.629.7
2.25.31
5.831.8
2.45.79
6.034.0
2.66.39
6.236.4
2.87.41
6.438.7
3.08.51
6.641.2
3.29.68
6.843.7
3.410.9
7.046.3
3.612.3
7.249.0
3.813.7
7.451.8
4.015.1
7.654.6
4.216.7
7.857.5
4.418.3
7.95659.9
Wall-mounted
unit
(b)
m (kg)
A
min
(m2)
Floor-standing
unit
(c)
m (kg)
A
min
(m2)
1.2.3 Dzesējošā viela
Ja tiek izmantots. Plašāku informāciju skatiet uzstādīšanas rokasgrāmatā vai
attiecīgā lietojuma uzstādītāja uzziņu rokasgrāmatā.
(a) Ceiling-mounted unit (= bloks uzstādīts pie griestiem)
(b) Wall-mounted unit (= bloks uzstādīts pie sienas)
(c) Floor-standing unit (= bloks uzstādīts uz grīdas)
PAZIŅOJUMS
Nodrošiniet, lai dzesējošās vielas cauruļu uzstādīšana tiktu veikta saskaņā ar
piemērojamo likumdošanu. Eiropā piemērojamais standarts ir EN378.
PAZIŅOJUMS
Gādājiet, lai ārējie cauruļvadi NEBŪTU noslogoti.
BRĪDINĀJUMS
Pārbaužu laikā NEKAD nelietojiet produktā spiedienu, kas ir lielāks par maksimālo
pieļaujamo spiedienu (kas norādīts datu plāksnītē uz iekārtas).
BRĪDINĀJUMS
Ja tiek konstatēta dzesētāja noplūde, veiciet visus nepieciešamos piesardzības
pasākumus. Ja tiek konstatēta dzesētāja gāzes noplūde, nekavējoties izvēdiniet
telpas. Iespējamie riski:
▪ Pārmērīga dzesētāja koncentrācija slēgtā telpā var radīt skābekļa trūkumu.
▪ Ja dzesētāja gāze nokļūst saskarē ar liesmām, var rasties toksiska gāze.
Uzstādītāja uzziņu grāmata
9
1 | Vispārīgas drošības piesardzības pasākumi
BĪSTAMI! EKSPLOZIJAS IZRAISĪŠANAS RISKS
Izsūknēšana— aukstumaģenta noplūde. Ja vēlaties izsūknēt sistēmu un ir noplūde
aukstumaģenta kontūrā:
▪ NEIZMANTOJIET iekārtas automātiskas izsūknēšanas funkciju, ar kuru varat visu
aukstumaģentu no sistēmas pārsūknēt ārējā blokā. Iespējamās sekas: Iespējama
kompresora aizdegšanās un sprādziens, ja gaiss ieplūst kompresorā, kad tas
darbojas.
▪ Izmantojiet atsevišķu atgūšanas sistēmu, lai NEDARBINĀTU iekārtas kompresoru.
BRĪDINĀJUMS
VIENMĒR veiciet aukstumaģenta atgūšanu. NEPIEĻAUJIET aukstumaģenta noplūdi
apkārtējā vidē. Izmantojiet vakuumsūkni, lai atgaisotu iekārtu.
PAZIŅOJUMS
Kad visas caurules ir savienotas, pārbaudiet, vai nav gāzes noplūdes. Gāzes noplūdes
noteikšanai izmantojiet slāpekli.
PAZIŅOJUMS
▪ Lai novērstu kompresora darbības traucējumus, NEDRĪKST iepildīt vairāk par
norādīto aukstumaģenta daudzumu.
▪ Kad nepieciešams atvērt aukstumaģenta sistēmu, ar aukstumaģentu jārīkojas
saskaņā ar attiecīgajiem noteikumiem.
BRĪDINĀJUMS
Nodrošiniet, lai sistēmā nebūtu skābekļa. Dzesētāju drīkst uzpildīt tikai pēc tam, kad
ir veikta noplūdes pārbaude un vakuumžāvēšana.
Iespējamās sekas: Kompresora pašaizdegšanās un eksplozija, jo skābeklis iekļūst
strādājošā kompresorā.
▪ Ja nepieciešama atkārtota uzpilde, sk. iekārtas datu plāksnīti. Tur ir norādīts
aukstumaģenta tips un vajadzīgais daudzums.
▪ Iekārta fabrikā ir piepildīta ar aukstumaģentu, bet dažām sistēmām var būt
nepieciešama papildu uzpildīšana atkarībā no cauruļu izmēriem un to garuma.
▪ Lietojiet tikai šajā sistēmā izmantotajam dzesēšanas šķidrumam paredzētos rīkus,
lai nodrošinātu spiedienizturību un novērstu svešķermeņu iekļūšanu sistēmā.
▪ Dzesēšanas šķidruma uzpildīšana tiek veikta šādi:
JaTad
Tiek lietota sifona caurule
(piemēram, cilindram ir apzīmējums
Veiciet uzpildīšanu ar augšupvērstu
cilindru.
“Pievienots šķidruma uzpildīšanas
sifons”)
Uzstādītāja uzziņu grāmata
10
Sifona caurule NETIEK lietotaVeiciet uzpildīšanu ar lejupvērstu
cilindru.
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin telpu gaisa kondicionētājs
4P513661-8H – 2019.12
1.2.4 Sālsūdens
1 | Vispārīgas drošības piesardzības pasākumi
▪ Lēnām atveriet dzesēšanas cilindrus.
▪ Uzpildiet dzesētāju šķidruma veidā. Ja tiks pievienots gāzes veida dzesētājs, var
tikt traucēta darbība.
UZMANĪBU!
Pēc aukstumaģenta iepildīšanas procedūras beigām vai procedūras pārtraukumā
uzreiz noslēdziet aukstumaģenta tvertnes vārstu. Ja vārstu NENOSLĒDZ uzreiz, tad
atlikušā spiediena ietekmē var tikt iepildīts lieks aukstumaģenta daudzums.
Iespējamās sekas: Nepareizs aukstumaģenta daudzums.
Ja tiek lietots. Plašāku informāciju skatiet uzstādīšanas rokasgrāmatā vai attiecīgā
lietojuma uzstādītāja uzziņu rokasgrāmatā.
BRĪDINĀJUMS
Sālsūdens IR jāizvēlas saskaņā ar piemērojamo likumdošanu.
BRĪDINĀJUMS
Ja tiek konstatēta sālsūdens noplūde, veiciet visus nepieciešamos piesardzības
pasākumus. Sālsūdens noplūdes gadījumā nekavējoties izvēdiniet telpas un
sazinieties ar vietējo tirgotāju.
1.2.5 Ūdens
BRĪDINĀJUMS
Iekārtā esošā gaisa temperatūra var būt daudz augstāka par temperatūru telpā,
piemēram, 70°C. Sālsūdens noplūdes gadījumā ierīcē esošās sakarsušās daļas var
izraisīt bīstamu situāciju.
BRĪDINĀJUMS
Instalācija IR jāizmanto un jāuzstāda saskaņā ar piemērojamajā likumdošanā
noteiktajiem drošības un vides aizsardzības pasākumiem.
Ja tiek lietots. Plašāku informāciju skatiet uzstādīšanas rokasgrāmatā vai attiecīgā
lietojuma uzstādītāja uzziņu rokasgrāmatā.
PAZIŅOJUMS
Pārliecinieties, vai ūdens kvalitāte atbilst ES direktīvā 98/83EK noteiktajām prasībām.
▪ Pirms noņemat slēdžu kārbas vāku, pievienojat elektriskos vadus vai pieskaraties
elektriskajām daļām, pilnībā ATSLĒDZIET strāvas padevi.
▪ Pirms apkopes veikšanas strāvas padevei jābūt atvienotai ilgāk nekā minūti un ir
jāveic sprieguma mērīšana galvenās ķēdes kondensatoru spailēs vai elektriskajās
daļās. Pirms pieskaršanās elektriskajām daļām līdzstrāvas spriegumam JĀBŪT
mazākam par 50 V. Spaiļu atrašanās vietu skatiet elektroinstalācijas shēmā.
▪ NEPIESKARIETIES elektriskajām daļām ar mitrām rokām.
▪ NEATSTĀJIET iekārtu bez uzraudzības, ja ir noņemts apkopes pārsegs.
BRĪDINĀJUMS
Ja rūpnīcā NAV uzstādīts galvenais slēdzis vai cits atvienošanas līdzeklis, kas kontaktus
atvieno visos polos, nodrošinot pilnīgu atvienošanu atbilstoši pārsprieguma III
kategorijas nosacījumiem, tas ir OBLIGĀTI jāiekļauj fiksētajā elektroinstalācijā.
BRĪDINĀJUMS
▪ Izmantojiet TIKAI vara vadus.
▪ Gādājiet, lai ārējie vadi atbilstu attiecīgo noteikumu prasībām.
▪ Ārējā elektroinstalācija ir jāveido atbilstoši iekārtas komplektācijā iekļautajai
elektroinstalācijas shēmai.
▪ NESASPIEDIET saišķī esošos kabeļus un gādājiet, lai tie nesaskartos ar caurulēm un
asām malām. Nodrošiniet, lai spaiļu savienojumiem netiktu pielietots ārējs
spiediens.
▪ Noteikti ierīkojiet zemējumu. NESAVIENOJIET iekārtas zemējumu ar komunālā
tīkla caurulēm, izlādni vai tālruņa līnijas zemējumu. Nepilnīgs zemējums var
izraisīt elektriskās strāvas triecienu.
▪ Noteikti izmantojiet atsevišķu energoapgādes avotu. NEKAD neizmantojiet
energoapgādes avotu, kas tiek koplietots ar citu ierīci.
▪ Noteikti uzstādiet nepieciešamos drošinātājus vai jaudas slēdžus.
▪ Noteikti ierīkojiet noplūdstrāvas aizsardzību. Ja to neizdara, tad iespējams
elektriskās strāvas trieciens vai aizdegšanās.
▪ Kad uzstādāt noplūdstrāvas aizsardzību, pārbaudiet, vai tā ir saderīga ar invertoru
(izturīga pret augstfrekvences elektrisko troksni), lai izvairītos no nevajadzīgas
noplūdstrāvas aizsardzības nostrādāšanas.
Uzstādītāja uzziņu grāmata
12
UZMANĪBU!
Kad pieslēdz elektrisko barošanu, pirms tam ir jāizveido zemējums. Kad atvieno
elektrisko barošanu, strāva jāatvieno pirms zemējuma atvienošanas. Vadu garumam
starp barošanas vada atslogotāju un spaiļu paneli jābūt tādam, lai strāvas vadus
varētu pieslēgt pirms zemējuma gadījumam, ja strāvas vads tiktu atrauts no
atslogotāja.
FTXP50~71M2V1B + FTXF20~71A2V1B + ATXF50~71A2V1B
Daikin telpu gaisa kondicionētājs
4P513661-8H – 2019.12
1 | Vispārīgas drošības piesardzības pasākumi
PAZIŅOJUMS
Piesardzības pasākumi strāvas kabeļu uzstādīšanas laikā:
▪ Strāvas spaiļu blokam NEPIEVIENOJIET dažāda biezuma vadus (vaļīgs strāvas vads
var radīt pārlieku lielu karšanu).
▪ Pievienojot vienāda diametra vadus, dariet to, kā parādīts attēlā iepriekš.
▪ Vadiem lietojiet paredzētajai strāvai atbilstošus vadus un stingri pievienojiet, pēc
tam nostipriniet tos, lai novērstu ārējā spiediena izplešanos ārpus spaiļu plates.
▪ Lai pievilktu spaiļu skrūves, lietojiet atbilstošu skrūvgriezi. Skrūvgriezis ar mazu
galvu var sabojāt skrūves galviņu un nenodrošinās pareizu pievilkšanu.
▪ Pārvelkot spaiļu skrūves, tās var salauzt.
BRĪDINĀJUMS
▪ Pēc elektroinstalācijas darbu pabeigšanas pārliecinieties, vai visas elektriskās
daļas un spailes elektrisko daļu kārbā ir droši savienotas.
▪ Pirms iekārtas iedarbināšanas pārliecinieties, vai visi pārsegi ir aizvērti.
PAZIŅOJUMS
Attiecināms tikai tad, ja barošanas blokam ir trīs fāzes un kompresoram ir
ieslēgšanas/izslēgšanas iespēja.
Ja pēc īslaicīga elektropadeves traucējuma iespējama pretfāze un produkta darbības
laikā strāvas padeve tiek ieslēgta un izslēgta, pievienojiet lokālu pretfāzes
aizsardzības ķēdi. Produktu darbinot pretfāzē, var sabojāt kompresoru un citas daļas.
Pārliecinieties, ka lietotājam ir dokumentācija uz papīra, un aiciniet viņu saglabāt to
turpmākai uzziņai.
INFORMĀCIJA
Ir paredzēts, ka šo iekārtu izmanto speciālisti vai apmācīti lietotāji veikalos, vieglajā
rūpniecībā un zemnieku saimniecībās, vai arī nelietpratīgas personas uzņēmumos un
mājsaimniecībās.
Šis dokuments ir daļa no dokumentācijas komplekta. Pilns komplekts sastāv no
tālāk norādītajiem dokumentiem.
▪ Vispārējie drošības noteikumi:
- Izlasiet šos drošības noteikumus PIRMS iekārtas uzstādīšanas
- Formāts: uz papīra (iekšējā bloka iepakojumā)
▪ Iekšējā bloka uzstādīšanas rokasgrāmata:
- Uzstādīšanas instrukcija
- Formāts: uz papīra (iekšējā bloka iepakojumā)
▪ Uzstādītāja uzziņu rokasgrāmata:
- Uzstādīšanas sagatavošana, labā prakse, atsauces dati…