Daikin FHYBP60B7V1 user guide manual

OPERATION MANUAL
Split system air conditioners
FHYBP35B7V1 FHYBP45B7V1 FHYBP60B7V1 FHYBP71B7V1 FHYBP100B7V1 FHYBP125B7V1
FHYCP35B7V1 FHYCP45B7V1 FHYCP60B7V1 FHYCP71B7V1 FHYCP100B7V1 FHYCP125B7V1
FDYP125B7V1 FDYP200B7V1 FDYP250B7V1
FBQ35B7V1 FBQ50B7V1 FBQ60B7V1 FBQ71B7V3B FBQ100B7V3B FBQ125B7V3B
FHYBP71B8V1 FHYBP100B8V1 FHYBP125B8V1
FHYCP71B8V1 FHYCP100B8V1 FHYCP125B8V1
FDYP125B8V1 FDYP200B8V1 FDYP250B8V1
FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B
FCQ35B7V1 FCQ50B7V1 FCQ60B7V1 FCQ71B7V3B FCQ100B7V3B FCQ125B7V3B
FDQ125B7V3B FDQ200B7V3B FDQ250B7V3B
FCQ35B8V1 FCQ50B8V1 FCQ60B8V1 FCQ71B8V3B FCQ100B8V3B FCQ125B8V3B
FDQ125B8V3B
3
1
9
6
5
4
7 7
6
7
6
1
4
1
1
4
R35-45-60
RR71-100-125
RP200-250
RY35-45-60
RQ71-100-125
RS50-60 RKS35-50-60 RXS35-50-60
3MKS50 4MKS58-75-90 3MXS52 4MXS68-80
RZQ71-100-125-140
RZQ200-250
3
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
18-33 12-24
18-35 14-25
18-35 14-24
18-33 12-24
18-35 12-25
21-32 14-23
21-32 14-23
18-35 12-28
18-35 14-28
2
80%
80%
80%
80%
80%
80%
5
8
–15~43
–15~46
–5~43
–5~43
–5~46
–10~46
–10~46
–15~50
–5~46
5
4
1
3
2
3
8
2
A
2
8
12
B
1 1
3
RY35-45-60
RQ71-100-125
RYP200-250
RXS35-50-60
3MXS52 4MXS68-80
RZQ71-100-125-140
RZQ200-250
°C DB
°C DB
°C DB
°C DB
°C DB
°C DB
°C DB
15-27
15-24
15-24
10-30
10-30
10-27
10-27
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
°C DB °C WB
–9~21 –10~15.5
–9~21 –10~15
–9~21 –10~15.5
–14~24 –15~18
–14~21 –15~15.5
–13~21 –20~15.5
–14~21 –15~15
4 5
6
6
7
5
1
2 1
7
8
FHYBP FHYCP FDYP
ONTENTS
C
What to do before operation..............................................................1
Names and functions of parts............................................................ 1
Operation range.................................................................................2
Installation and installation site.......................................................... 2
Operation procedure..........................................................................2
Optimum operation............................................................................2
Not a malfunction of the air conditioner.............................................3
Troubleshooting ................................................................................. 4
Maintenance......................................................................................4
THANK YOU FOR PURCHASING THIS DAIKIN AIR CONDITIONER. CAREFULLY READ THIS OPERATION MANUAL BEFORE USING THE AIR CONDITIONER. IT WILL TELL YOU HOW TO USE THE UNIT PROPERLY AND HELP YOU IF ANY TROUBLE OCCURS. AFTER READING THE MANUAL, FILE IT AWAY FOR FUTURE REFERENCE.
W
Ask your dealer for installation and re-installation of the air conditioner.
Incomplete installation performed by yourself may result in water leakage, electric shock and fire.
Be sure only to use accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a professional.
This operation manual is for the following systems with standard control. Before initiating operation, contact your Daikin dealer for the operation manual that corresponds to your system.
If your installation has a customised control system, ask your Daikin dealer for the operation that corresponds to your system.
HAT
TO
A
B
1 2
Heat pump type This system provides cooling, heating, automatic, and fan operation modes.
Straight cooling type This system provides cooling, and fan operation modes.
DO
BEFORE
Pair system or simultaneous operation system Multi system
Unit with remote controller Unit without remote controller (When used as simultaneous
operation)
FBQ FCQ FDQ
OPERATION
(See figure 2)
Split system air conditioners
age
P
AMES
N
Operation manual
It is not good for your health to expose your body to the direct air flow for a long time.
In order to avoid electric shock, fire or injury, if you detect any abnormability such as smell of fire, turn off power and call your dealer for instructions.
Never let the indoor unit and the remote controller get wet. Do not operate the air conditioner with wet hands. It may cause an electric shock or a fire.
Do not put a finger, rod or other objects into the air inlet or outlet. As the fan is rotating at high speed, it will cause injury.
Never remove the fan guard of the outdoor unit. The rotating fan at high speed without the guard is very dangerous.
Ask your dealer for improvement, repair and maintenance. Never inspect or service the unit by yourself. Incomplete improvement, repair and maintenance may result in water leakage, electric shock and fire.
The refrigerant in the air conditioner is safe and normally does not leak. If the refrigerant leaks inside the room, the contact with a fire of a burner, heater or cooker may result in a harmful gas. Do not use the air conditioner until a service person confirms to finish repairing the portion where the refrigerant leaks.
For refrigerant leakage, consult your dealer. When the air conditioner is to be installed in a small room, it is necessary to take proper measures so that the amount of any leaked refrigerant does not exceed the concentration limit, even when it leaks. If the refrigerant leaks exceed the level of the concentration limit, an oxygen deficiency accident may happen.
AND
1 2 3 4 5 6 7
9
FUNCTIONS
Indoor unit Outdoor unit Remote controller Inlet air Discharged air Refrigerant piping, connection electric wire Drain pipe
Ground wire
Wire to ground outdoor unit to prevent electric shocks. Air filter
OF
PARTS
(See figure 1)
FHYBP + FHYCP + FDYP + FBQ + FCQ + FDQ Split system air conditioners 4PW10622-1E
Operation manual
1