Daikin FH(Y)35BJV1 user guide manual

OPERATION MANUAL
SPLIT SYSTEM Air Conditioner
English
MODELS
(Ceiling suspension type)
FH(Y)35BJV1 FHYP35BV1 FH35BZV1 FHQ35BUV1B FH(Y)45BJV1 FHYP45BV1 FH45BZV1 FHQ50BUV1B FH(Y)60BJV1 FHYP60BV1 FH60BZV1 FHQ60BUV1B FHY71BJV1 FHYP71BV1 FHY100BJV1 FHYP100BV1 FHY125BJV1 FHYP125BV1
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Portugues
Рóссêий
5
12
4
2
1
3
hr
hr
C
NOT
AVAILABLE
LH
9 11 10
13 21
14
7
6 8
TEST
20
TEST
16
1
15
17
18
22
19
[1]
f
e
e
g
d
j
a
d
c
k
i
3
h
b
d
e
f
hr
k
42
C
H
Thank you for purchasing this Daikin air condi­tioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference.
Σαò ευχαριστοýìε που αγορÜσατε τη συσκευÞ κλιìατισìοý. ÄιαβÜστε προσεκτικÜ αυτÝò τιò οδηγßεò χρÞσηò πριν να χρησιìοποιÞσετε τη συσκευÞ κλιìατισìοý. Θα σαò πουν πωò θα χρησιìοποιÞσετε σωστÜ τη ìονÜδα και θα σαò βοηθÞσουν αν εìφανιστοýν προβλÞìατα. Aφοý διαβÜσετε τιò οδηγßεò, βÜλτε τιò στο αρχεßο σαò για ìελλοντικÞ αναφορÜ.
Vielen Dank für den Kauf einer Klimaanlage von Daikin. Bitte lesen Sie diese Bedienungsanlei­tung vor der Inbetriebnahme des Gerätes gründlich durch. Hier wird erklärt, wie das Gerät richtig eingesetzt wird und was bei Störungen zu tun ist. In dieser Anleitung wird nur das Innenag­gregat beschrieben. Verwenden Sie diese Anlei­tung zusammen mit der Bedienungsanleitung des Außenaggregats. Nach dem Lesen der Anleitung legen Sie diese griffbereit zum Nach­schlagen auf.
Nous vous remercions pour votre acquisition de ce climatiseur Daikin. Lisez attentivement ce manuel avant d’utiliser le climatiseur. Il vous expliquera comment vous servir correctement de l’appareil et vous guidera en cas de problème. Lorsque vous aurez lu le manuel, rangez-le afin de pouvoir vous y référer ultérieurement.
Le agradecemos la compra de este acondicio­nador de aire Daikin. Lea cuidadosamente el manual de funcionamiento antes de utilizar el acondicionador de aire. Dicho manual le indi­cará cómo utilizar adecuadamente la máquina y le ayudará en caso de avería. Después de leer el manual, consérvelo para consultas futuras.
La ringraziamo di aver acquistato questo con­dizionatore d’aria Daikin. Leggere attentamente questo manuale prima di avviare il condizion­atore. Ciò permetterà di usare correttamente l’unità e di ottenere un aiuto in caso di anomalia di funzionamento. Dopo aver letto il manuale, conservarlo in un luogo accessibile per una futura necessità.
Wij danken u voor de aankoop van deze Daikin airconditioner. Lees deze bedrijfshandleiding aandachtig door voordat u de airconditioner gebruikt. Het omvat uitleg over het correcte gebruik van de unit en biedt hulp in geval een storing mocht optreden. Gebruik deze handled­ing voor verdere raadpleging.
Obrigado pela sua compra deste aparelho de ar condicionado Daikin. Leia com atenção este manual de operação antes de proceder à utilização do aparelho de ar condicionado. Este indicar-lhe-á como deverá utilizar a unidade correctamente e ajudá-lo-á no caso de surgir qualquer problema. Depois de ler o manual, guarde-o num local seguro a fim de o poder consultar caso venha a ser preciso.
Спасибо за поêóпêó данноãо êондиционера фирмы Daikin. До начала работы с êондиционером внимательно изóчите данное рóêоводство по эêсплóатации. В нем излаãаются правила надлежащеãо пользования óстройством и приводятся реêомендации пользователю по поисêó и óстранению неисправностей. После изóчения рóêоводства сохраните еãо для обращений в бóдóщем.
CONTENTS
ILLUSTRATIONS ................................................ [1]
1. WHAT TO DO BEFORE OPERATION.......... 1
2. SAFETY CONSIDERATIONS ....................... 1
3. OPERATION RANGE.................................... 3
4. INSTALLATION SITE .................................... 3
5. NAME AND FUNCTION OF EACH SWITCH AND DISPLAY ON THE REMOTE
CONTROLLER .............................................. 4
6. OPERATION PROCEDURE.......................... 5
7. OPTIMUM OPERATION................................ 7
8. MAINTENANCE
(FOR SERVICE PERSONNEL)..................... 8
9. NOT MALFUNCTION OF THE AIR
CONDITIONER.............................................. 9
10. TROUBLE SHOOTING................................ 11

1. WHAT TO DO BEFORE OPERATION

This operation manual is for the following systems with standard control. Before initiating operation, contact your Daikin dealer for the operation that cor­responds to your system.
Pair system or Simultaneous operation system
Indoor unit
Outdoor unit
Unit with remote controller
Multi system
Indoor unit Indoor unit
Outdoor unit
Unit with remote controller
Unit without remote controller (When used as simultaneous operation system)
Unit with remote controller
Heat pump type This system provides cooling, heating, automatic, program dry, and fan operation modes.
Cooling only type This system provides cooling, program dry, and fan operation modes.
PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM
This system provides two other control systems beside individual control (one remote controller con­trols one indoor unit) system. Confirm the following if your unit is of the following control system type.
• Group control system
One remote controller controls up to 16 indoor units. All indoor units are equally set.
• Two remote controllers control system
Two remote controllers control one indoor unit (In case of group control system, one group of indoor units) The unit is individually operated.
NOTE
Contact your Daikin dealer in case of changing
the combination or setting of group control and two remote controllers control system.
Names and functions of parts
Refer to figure 2 on page [1]
a Indoor unit
Outdoor unit
• The external appearance of the outdoor unit varies depending on its capacity class.
b
The outdoor unit shown in the figure is for reference to indicate features. Contact your Daikin Dealer and verify which outdoor unit you have.
c Remote controller d Inlet air e Discharged air
f Air outlet g Air flow flap (at air outlet) h Refrigerant piping, connection electric wire
i Drain pipe
Suction grille
j
The built-in air filter removes dust and dirt. Ground wire
k
Wire to ground from the outdoor unit to pre­vent electrical shocks.
NOTE
If the unit you purchased is controlled by a wire-
less remote controller, also refer to the wireless remote controller’s operation manual.
If your installation has a customized control system, ask your Daikin dealer for the operation that corre­sponds to your system.
1 English

2. SAFETY CONSIDERATIONS

We recommend that you read this instruction man­ual carefully before use to gain full advantage of the function of the air conditioner, and to avoid malfunc­tion due to erroneous handling. This air conditioner comes under the term “appliances not accessible to the general public.”
• The precautions described below are WARN­ING and CAUTION. These are very important precautions concerning safety. Be sure to observe all of them without fail.
WARNING .. These are the matters with possi-
bilities leading to serious conse­quences such as death or serious injury due to erroneous handling.
CAUTION ... These are the matters with possi-
bilities leading to injury or material damage due to erroneous han­dling including probabilities lead­ing to serious consequences in some cases.
• After reading, keep this manual at a place where any user can read at any time. Further­more, make certain that this operation manual is handed to a new user when he takes over the operation.
WARNING
Avoid exposure of your body directly to the cold air for a long time, or avoid excessive exposure of your body to the cold air.
Otherwise, your physical condition may be dete­riorated and/or your health may be ruined.
When the air conditioner is in abnormal con­ditions (smell of something burning, etc), unplug the power cord from the outlet, and contact the dealer where you purchased the air conditioner.
Continued operation under such circumstances may result in a failure, electric shock, and fire.
Ask your dealer for installation of the air con­ditioner.
Incomplete installation performed by yourself may result in a failure, a water leakage, electric shock, and fire.
Ask your dealer for improvement, repair, and maintenance.
Incomplete improvement, repair, and maintenance may result in a failure, a water leakage, electric shock, and fire.
Do not insert your finger, a stick, etc., into the air inlet, outlet, and fan blades.
A fan in high-speed running may result in injury.
For refrigerant leakage, consult your dealer.
When the air conditioner is to be installed in a small room, it is necessary to take proper mea­sures so that the amount of any leaked refriger­ant does not exceed the limiting concentration even when it leaks. If the refrigerant leaks exceeding the level of limiting concentration, an oxygen deficiency accident may happen.
For installation of separately sold compo­nent parts, ask a specialist.
Be sure to use the separately sold component parts designated by our company. Incomplete installation performed by yourself may result in a failure, a water leakage, electric shock, and fire.
Ask your dealer to move and reinstall the air conditioner.
Incomplete installation may result in a failure, a water leakage, electric shock, and fire.
Do not use any fuse with improper capacity.
The use of a piece of wire and whatnot may result in a failure and fire.
The refrigerant in the air conditioner is safe and normally does not leak. If the refrigerant leaks inside the room, the contact with a fire of a burner, a heater or a cooker may result in a harmful gas.
Do not use the air conditioner until when a ser­vice person confirms to finish repairing the por­tion where the refrigerant leaks.
CAUTION
Do not use the air conditioner for other purposes.
Do not use the air conditioner for a special appli­cation such as the storage of foods, animals and plants, precision machines, and art objects as otherwise the deterioration of quality may result.
Do not remove the air outlet of the outdoor unit.
The fan may get exposed and result in injury.
When the air conditioner is used in combination with burners or heaters, perform sufficient ventilation.
Insufficient ventilation may result in an oxygen deficiency accident.
Check and make sure that foundation blocks are not damaged after a long use.
If they are left in a damaged condition, the unit may fall and result in injury.
Neither place a flammable spray bottle near the air conditioner nor perform spraying.
Doing so may result in a fire.
To clean the air conditioner, stop operation, and unplug the power cord from the outlet.
Otherwise, an electric shock and injury may result.
Do not operate the air conditioner with a wet hand.
An electric shock may result.
Do not place items that might be damaged by water under the indoor unit.
Water may condensate and drip if the humidity reaches 80% or if the drain exit gets clogged.
Do not place a burner or heater at a place directly exposed to the wind from the air conditioner.
Incomplete combustion of the burner or heater may result.
Do not allow a child to mount on the outdoor unit or avoid placing any object on it.
Falling or tumbling may result in injury.
Do not expose animals and plants directly to the wind from the air conditioner.
Adverse influence to animals and plants may result.
Do not wash the air conditioner with water.
Electric shock or fire may result.
Do not install the air conditioner at any place where flammable gas may leak out.
If the gas leaks out and stays around the air con­ditioner, a fire may break out.
Be sure to install an earth leakage breaker.
Unless it is installed, an electric shock or fire may result.
English 2
Loading...
+ 10 hidden pages